Titanium implant surface etching has proven an effective method to enhance cell attachment. Despite the frequent use of hydrofluoric (HF) acid, many questions remain unresolved, including the optimal etching time and its effect on surface and biological properties. The objective of this study was to investigate the effect of HF acid etching time on Ti topography, surface chemistry, wettability, and cell adhesion. These data are useful to design improved acid treatment and obtain an improved cell response. The surface topography, chemistry, dynamic wetting, and cell adhesiveness of polished Ti surfaces were evaluated after treatment with HF acid solution for 0, 2; 3, 5, 7, or 10 min, revealing a time-dependent effect of HF acid on their topography, chemistry, and wetting. Roughness and wetting increased with longer etching time except at 10 min, when roughness increased but wetness decreased. Skewness became negative after etching and kurtosis tended to 3 with longer etching time. Highest cell adhesion was achieved after 5–7 min of etching time. Wetting and cell adhesion were reduced on the highly rough surfaces obtained after 10-min etching time.
Objectives: To evaluate in vitro the effect of cavity preparation with microburs and diamond-coated ultrasonic tips on the microleakage and marginal fit of six end-root filling materials. Study Design. The following materials were assessed: amalgam (Amalcap), zinc oxide eugenol (IRM), glass ionomer (Vitrebond), compomer (Cavalite), mineral particle aggregate (MTA) and composite (Clearfil). Cavity preparation was performed with microburs or diamond ultrasonic tips in single-root teeth. The seal was evaluated in two experiments: a microleakage assay on the passage of dye to the interface; and a scanning electron microscopy study and analysis of epoxy resin replicas, measuring the size of gaps in the interface between filling material and cavity walls. Multifactorial ANOVA, multiple comparison test and Student's t test were used for statistical analyses of the data, considering p<0.05 to be significant. Results: Clearfil and MTA achieved a hermetic seal. Leakage and interface gap size was greater with Cavalite than with Clearfil and MTA, followed by Vitrebond and IRM. The worst seal was obtained with Amalcap. The use of diamond-coated ultrasonic tips improved the seal and reduced the gap when using materials that did not hermetically seal the cavity (Amalcap, IRM, Cavalite, Vitrebond). The preparation technique did not affect materials that achieved a hermetic seal (Clearfil, MTA). Conclusions: Clearfil and MTA obtained a hermetic seal due to their excellent marginal fit and are the most recommended materials for clinical use, taking account of their sealing capacity. Ultrasonic cavity preparation is preferable because it improves the seal and marginal fit of materials that do not achieve a hermetic seal of the cavity (Amalcap, IRM, Cavalite, Vitrebond).
Clinical Relevance: Etch & rinse adhesives are much more micropermeable and affected by pulp fluid compared with self-etching adhesives. Pulp pressure reduces dentin sealing with etch & rinse adhesives but not with self-etching adhesives. Pulp pressure has no effect on enamel sealing, which is lower when self-etching adhesive is used.
1 January 2024 in The Journal of Advanced Prosthodontics