Purpose: This paper delineates a literature review on fire-induced progressive collapse on structures and the effect of high temperature on structures and elements. After the occurrences of fire in the World Trade Center in the USA, the researchers started concentrating on the progressive collapse that happens due to high temperature. Currently, most of the researchers are working on fire-induced progressive collapse on structures using high-temperature behavior on materials which are used for construction. The researchers have been doing an intensive study to find a better strategy to prevent the building from structural fire damage or collapse with available codes and guidelines throughout the world. This paper aims to provide a better understanding and analytical solutions on the basis of the recent works done by researchers in fire-induced progressive collapse and methods adopted to find the collapse mechanism. Design/methodology/approach: This paper is written by studying different literature papers of 109 related to progressive collapse on structures and fire-induced progressive collapse. Findings: The behavior of structures due to high temperature and collapse conditions due to fire in different scenarios is identified. Originality/value: This paper fulfills an identified need to study how the structure can withstand high-temperature conditions in our day-to-day lives.
16 February 2023 in Journal of Structural Fire Engineering
Purpose: This study delineates the effect of cover thickness on reinforced concrete (RC) columns and beams under an elevated fire scenario. Columns and beams are important load-carrying structural members of buildings. Under all circumstances, the columns and beams were set to be free from damage to avoid structural failure. Under the high-temperature scenario, the RC element may fail because of the material deterioration that occurs owing to the thermal effect. This study attempts to determine the optimum cover thickness for beams and columns under extreme loads and fire conditions.Design/methodology/approach: Cover thicknesses of 30, 40, 45, 50, 60 and 70 mm for the columns and 10, 20, 25, 30, 35, 40, 50, 60 and 70 mm for the beams were adopted in this study. Both steady-state and transient-state conditions under thermomechanical analysis were performed using the finite element method to determine the heat transfer through the RC section and to determine the effect of thermal stresses.Findings: The results show that the RC elements have a greater influence on the additional cover thickness at extreme temperatures and higher load ratios than at the service stages. The safe limits of the structural members were obtained under the combined effects of elevated temperatures and structural loads. The results also indicate that the compression members have a better thermal performance than the flexural members.Research limitations/implications: Numerical investigations concerning the high-temperature behavior of structural elements are useful. The lack of an experimental setup encourages researchers to perform numerical investigations. In this study, the finite element models were validated with existing finite element models and experimental results.Practical implications: The obtained safe limit for the structural members could help to understand their resistance to fire in a real-time scenario. From the safe limit, a suitable design can be preferred while designing the structural members. This could probably save the structure from collapse.Originality/value: There is a lack of both numerical and experimental research works. In numerical modeling, the research works found in the literature had difficulties in developing a numerical model that satisfactorily represents the structural members under fire, not being able to adequately understand their behavior at high temperatures. None of them considered the influence of the cover thickness under extreme fire and loading conditions. In this paper, this influence was evaluated and discussed.
14 August 2021 in Environmental Science and Pollution Research
When exposed to high temperatures, reinforced concrete members undergo major changes in their properties which in turn affects their structural performance. Fire accidents in frame structures at local or global level may lead to collapse of structures. Structural fire has dire consequences like collapse of structures, colour changes, spalling of concrete and failure of essential elements. It is essential to study the conduct of reinforced concrete frame under thermal expansion in order to understand fire-induced collapse of concrete structures. This study observes how a three dimensional single-bay single-storey reinforced concrete frame is performed under thermo-mechanical analysis in ABAQUS (FEA). The paper aims to note the effect of slab and infill wall with respect to thermal expansion. The paper also discusses the main findings regarding the structural performance, structural leading conditions and structural stiffness of the reinforced concrete frame with slab and infill wall under thermal expansion. The results found that the infill frame has better stiffness and performs well under fire conditions.