Norman Mangner

Prof. Dr. Norman Mangner

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2024 in New England Journal of Medicine
Verified
Journal Article
Closed access
JMJacob Eifer Møller
Jacob Eifer Møller
TEThomas Engstrøm
Thomas Engstrøm
LJLisette O. Jensen
Lisette O. Jensen
HEHans Eiskjær
Hans Eiskjær
NMNorman Mangner
Norman Mangner
CHChristian Hassager
Christian Hassager
The effects of temporary mechanical circulatory support with a microaxial flow pump on mortality among patients with ST-segment elevation myocardial infarction (STEMI) complicated by cardiogenic shock remains unclear. In an international, multicenter, randomized trial, we assigned patients with STEMI and cardiogenic shock to receive a microaxial flow pump (Impella CP) plus standard care or standard care alone. The primary end point was death from any cause at 180 days. A composite safety end point was severe bleeding, limb ischemia, hemolysis, device failure, or worsening aortic regurgitation. A total of 360 patients underwent randomization, of whom 355 were included in the final analysis (179 in the microaxial-flow-pump group and 176 in the standard-care group). The median age of the patients was 67 years, and 79.2% were men. Death from any cause occurred in 82 of 179 patients (45.8%) in the microaxial-flow-pump group and in 103 of 176 patients (58.5%) in the standard-care group (hazard ratio, 0.74; 95% confidence interval [CI], 0.55 to 0.99; P = 0.04). A composite safety end-point event occurred in 43 patients (24.0%) in the microaxial-flow-pump group and in 11 (6.2%) in the standard-care group (relative risk, 4.74; 95% CI, 2.36 to 9.55). Renal-replacement therapy was administered to 75 patients (41.9%) in the microaxial-flow-pump group and to 47 patients (26.7%) in the standard-care group (relative risk, 1.98; 95% CI, 1.27 to 3.09). The routine use of a microaxial flow pump with standard care in the treatment of patients with STEMI-related cardiogenic shock led to a lower risk of death from any cause at 180 days than standard care alone. The incidence of a composite of adverse events was higher with the use of the microaxial flow pump. (Funded by the Danish Heart Foundation and Abiomed; DanGer Shock ClinicalTrials.gov number, NCT01633502.).

12 October 2023 in New England Journal of Medicine
Verified
Journal Article
Closed access
BSBarbara E. Stähli
Barbara E. Stähli
FVFerdinando Varbella
Ferdinando Varbella
ALAxel Linke
Axel Linke
BSBettina Schwarz
Bettina Schwarz
SFStephan B. Felix
Stephan B. Felix
FRFrank Ruschitzka
Frank Ruschitzka
In patients with ST-segment elevation myocardial infarction (STEMI) with multivessel coronary artery disease, the time at which complete revascularization of nonculprit lesions should be performed remains unknown. We performed an international, open-label, randomized, noninferiority trial at 37 sites in Europe. Patients in a hemodynamically stable condition who had STEMI and multivessel coronary artery disease were randomly assigned to undergo immediate multivessel percutaneous coronary intervention (PCI; immediate group) or PCI of the culprit lesion followed by staged multivessel PCI of nonculprit lesions within 19 to 45 days after the index procedure (staged group). The primary end point was a composite of death from any cause, nonfatal myocardial infarction, stroke, unplanned ischemia-driven revascularization, or hospitalization for heart failure at 1 year after randomization. The percentages of patients with a primary or secondary end-point event are provided as Kaplan-Meier estimates at 6 months and at 1 year. We assigned 418 patients to undergo immediate multivessel PCI and 422 to undergo staged multivessel PCI. A primary end-point event occurred in 35 patients (8.5%) in the immediate group as compared with 68 patients (16.3%) in the staged group (risk ratio, 0.52; 95% confidence interval, 0.38 to 0.72; P<0.001 for noninferiority and P<0.001 for superiority). Nonfatal myocardial infarction and unplanned ischemia-driven revascularization occurred in 8 patients (2.0%) and 17 patients (4.1%), respectively, in the immediate group and in 22 patients (5.3%) and 39 patients (9.3%), respectively, in the staged group. The risk of death from any cause, the risk of stroke, and the risk of hospitalization for heart failure appeared to be similar in the two groups. A total of 104 patients in the immediate group and 145 patients in the staged group had a serious adverse event. Among patients in hemodynamically stable condition with STEMI and multivessel coronary artery disease, immediate multivessel PCI was noninferior to staged multivessel PCI with respect to the risk of death from any cause, nonfatal myocardial infarction, stroke, unplanned ischemia-driven revascularization, or hospitalization for heart failure at 1 year. (Supported by Boston Scientific; MULTISTARS AMI ClinicalTrials.gov number, NCT03135275.).

1 June 2017 in JACC: Heart Failure
Verified
Journal Article
Closed access
SSStephan Schürer
Stephan Schürer
KKKarin Klingel
Karin Klingel
MSMarcus Sandri
Marcus Sandri
NMNicolas Majunke
Nicolas Majunke
CBChristian Besler
Christian Besler
NMNorman Mangner
Norman Mangner

11 January 2023 in JACC: Heart Failure
Verified
Journal Article
Closed access
BSBenedikt Schrage
Benedikt Schrage
JSJonas Sundermeyer
Jonas Sundermeyer
SBStefan Blankenberg
Stefan Blankenberg
PCPascal Colson
Pascal Colson
DEDennis Eckner
Dennis Eckner
DWDirk Westermann
Dirk Westermann

1 December 2014 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
NMNorman Mangner
Norman Mangner
KSKathrin Scheuermann
Kathrin Scheuermann
EWEphraim Winzer
Ephraim Winzer
IWIsabel Wagner
Isabel Wagner
RHRobert Hoellriegel
Robert Hoellriegel
SESandra Erbs
Sandra Erbs

1 April 2022 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
BSBruno Scheller
Bruno Scheller
TRTuomas T. Rissanen
Tuomas T. Rissanen
AFAhmed Farah
Ahmed Farah
MOMarc-Alexander Ohlow
Marc-Alexander Ohlow
NMNorman Mangner
Norman Mangner
FIfor the BASKET-SMALL 2 Investigators
for the BASKET-SMALL 2 Investigators
Background: Patients at high-bleeding risk (HBR) undergoing percutaneous coronary intervention represent a challenging patient population. The use of drug-coated balloon (DCB) allows shorter duration of dual antiplatelet therapy compared with drug-eluting stents (DES) and reduces thrombotic risk due to the absence of a permanent implant. The present analysis aimed to investigate if the effect of DCB versus DES differed between patients with and without HBR treated with percutaneous coronary intervention in small coronary arteries. Methods: This prespecified subgroup analysis of a multicenter, randomized, noninferiority trial included 758 patients with de novo lesions in coronary vessels <3 mm and an indication for percutaneous coronary intervention, randomized to DCB (n=382) or second-generation DES (n=376). Patients were followed over 3 years for major adverse cardiac events. Results: Of the 758 patients randomized, 155 (20%) had HBR; these patients had higher mortality at 3 years (hazard ratio [95% CI], 3.09 [1.78–5.36]; P <0.001). Rates of major bleeding events were overall low but tended to be lower after DCB versus DES (1.6% versus 3.7%; P =0.064), were similar in patients with HBR (4.5% versus 3.4%) but less frequent in DCB-versus DES-treated patients without HBR (0.9% versus 3.8%). There was no difference in major adverse cardiac events between DCB and DES regardless of bleeding risk (HBR, hazard ratio: 1.16 [0.51–2.62]; P =0.719 versus non-HBR, 0.96 [0.62–1.49]; P =0.863). Conclusions: DCBs were similarly safe and effective as current-generation DES in the treatment of coronary arteries <3 mm, regardless of bleeding risk. In patients treated with DCB, there was a trend towards a reduction of severe bleeding events at 3 years. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01574534.