Jun-Seop Lee

Prof. Jun-Seop Lee

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2025 in Journal of Building Engineering
Verified
Journal Article
Closed access
DSDonghyeon Seol
Donghyeon Seol
HKHongjin Kim
Hongjin Kim
SPSunghyun Park
Sunghyun Park
JLJun-Seop Lee
Jun-Seop Lee

7 July 2023 in Structures
Verified
Journal Article
Closed access
JLJun-Seop Lee
Jun-Seop Lee
MHMuhammad Haroon
Muhammad Haroon
SKSeong-Hun Kang
Seong-Hun Kang
KSKyung-Jae Shin
Kyung-Jae Shin
HLHee-Du Lee
Hee-Du Lee

9 November 2020 in International Journal of Steel Structures
Verified
Journal Article
Closed access
PDF file
JLJun-Seop Lee
Jun-Seop Lee
KSKyung-Jae Shin
Kyung-Jae Shin
HLHee-Du Lee
Hee-Du Lee
JWJong-Hun Woo
Jong-Hun Woo

10 June 2021 in International Journal of Steel Structures
Verified
Journal Article
Closed access
PDF file
JLJun-Seop Lee
Jun-Seop Lee
HLHee-Du Lee
Hee-Du Lee
KSKyung-Jae Shin
Kyung-Jae Shin
HKHongjin Kim
Hongjin Kim
KLKang-Min Lee
Kang-Min Lee

30 December 2023 in Results in Engineering
Verified
Journal Article
Open access
JLJun-Seop Lee
Jun-Seop Lee
MHMuhammad Haroon
Muhammad Haroon
KSKyung-Jae Shin
Kyung-Jae Shin
JWJong-Hun Woo
Jong-Hun Woo
HLHee-Du Lee
Hee-Du Lee

27 January 2024 in Heliyon
Verified
Journal Article
Open access
MHMuhammad Haroon
Muhammad Haroon
HLHee-Du Lee
Hee-Du Lee
KSKyung-Jae Shin
Kyung-Jae Shin
JWJong-Hun Woo
Jong-Hun Woo
JLJun-Seop Lee
Jun-Seop Lee
The current design codes i.e. AISC 360-16, CSA-S16-19, EC-04 etc. provide empirical relationships to estimate the capacity of shear connectors which were developed based on pushout tests of headed studs and channels connectors in exposed type sections. Therefore, these equations may result inaccurate predictions for strength of connectors in infilled-type sections. This study presents a detailed experimental study investigating the performance of angle connectors in composite sections. The testing program consisted two series of pushout tests. A total of 36 specimens were tested, considering the influence of several important parameters i.e. the length (Lc), height (hc), and web-thickness (tw) of angle connector, length of the weld (w) and the direction of shear connector (forward/backward) etc. The tests results demonstrated that with increasing connector height hs, and thickness, the maximum load Pmax and slip δu were increased. The connector direction didn't change much the load-slip behavior. The prediction accuracy of the existing shear capacity models was evaluated by comparing the predictions with experimental results. The current equations were noticed to be highly inconsistent in predicting the shear capacity of angle connectors, especially in case of infilled type sections. When the entire length of connector was taken as the effective length, the models overestimated the shear capacity. While in case when the welding length was taken as effective length in calculations, the models underestimated the shear strength of angle connectors.