The general assumption of a rigid base at the bottom of building structures during analysis and design underestimates the seismic response. Building structures resting on loose sand and soft clayey soil are vulnerable to earthquake forces. The amplification of ground motion occurs due to the presence of this loose and soft soil deposit. Moreover, the spacing and slenderness ratio of piles play a vital role in altering the behavior of the overall soil-foundation-superstructure system. This study aimed at investigating the effect of soil-pile-structure interaction using 1-g shake-table testing. Free and forced vibration tests were performed on scaled building frames with either a rigid base or a flexible base, supported on sandy soil with 50% relative density. A laminar shear box container is used for an experimental study of soil-pile-structure interaction. The design parameters, such as the spacing (S = 3D, 5D, 7D, and 9D) and slenderness ratio (L/D = 15, 30, 45, and 60) of the piles, where S, D and L are spacing, diameter and length of the piles respectively, are considered in the analysis. The results, in terms of natural frequency, damping, pile-bending moment, story lateral displacement, and inter-story drift are estimated. From the findings, it is clear that the effects due to pile spacing are more considerable than the effects due to the slenderness ratio of the piles. The bending moment in the piles spaced at 3D is increased by 102% compared to the large-spacing (S = 9D) piles. This subsequently amplifies the story lateral displacement by 180% and amplifies the inter-story drift by 167%.
1 November 2017 in IOP Conference Series: Materials Science and Engineering
The horizontal in-plane shear interaction between the profiled cold-formed steel decking and concrete over is the prime factor that determines the strength of a composite concrete-steel deck slab. The control of slippage between concrete and steel is the most vital part to curb the central deflection. The means to reduce the slippage thereby to improve the shear interaction includes the provision of shear studs, ribs, embossments and other means. In this paper, the study on presence of embossments in steel sheeting and the effect of various parameters such as size, shape such as rectangular, square and circular, and the alignment of embossments, in the shear capacity and ultimate strength of the composite slab using three-dimensional computational finite element modeling is presented. It is found that change in shape, size and alignment of embossments is affected in the shear resistance of the composite slab.
13 September 2024 in Geomatics, Natural Hazards and Risk
The response reduction factor or response modification factor (R) plays an important role in the non-linear response of the moment resisting reinforced concrete (RC) frames. Implementing this factor in the design, accounts for the non-linear response of a structure. The study emphasizes on evaluating the actual values of the response reduction factor for moment resisting RC frames. The estimation of this factor is carried out by performing a detailed non-linear static pushover analysis of 2D framed structures of both ductile and ordinary moment resisting frames.Different parameters considered for the study includes variation of height of the structure, the zone factor and considering the effect of geometric non-linearity of the structure in the analysis. The results indicate that the values of R as given by the codes are of higher degree. From the analysis, arelationship between R-T-Z has been studied. It is found that the values of over-strength, ductility and response reduction factors are highly affected by seismic zones and time period of the structure.
22 June 2024 in Geomatics, Natural Hazards and Risk