Alexey A Morozov

Dr. Alexey A Morozov

orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2004 in Applied Physics A
Verified
Journal Article
Closed access
PDF file
Alexey A MorozovAlexey A Morozov
Alexey A Morozov

2 February 2015 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
Alexey A MorozovAlexey A Morozov
Alexey A Morozov
AEA. B. Evtushenko
A. B. Evtushenko
ABAlexander Bulgakov
Alexander Bulgakov
The expansion of a plume produced by low-fluence laser ablation of graphite in vacuum is investigated experimentally and by direct Monte Carlo simulations in an attempt to explain hyperthermal particle energies for thermally vaporized materials. We demonstrate that the translation energy of neutral particles, ∼2 times higher than classical expectations, is due to two effects, hydrodynamic plume acceleration into the forward direction and kinetic selection of fast particles in the on-axis region. Both effects depend on the collision number within the plume and on the particles internal degrees of freedom. The simulations allow ablation properties to be evaluated, such as ablation rate and surface temperature, based on time-of-flight measurements. Available experimental data on kinetic energies of various laser-produced particles are well described by the presented model.

12 February 2021 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
Alexey A MorozovAlexey A Morozov
Alexey A Morozov
SSSergey Viktorovich Starinskiy
Sergey Viktorovich Starinskiy
ABAlexander Bulgakov
Alexander Bulgakov
Pulsed laser ablation of compound materials often occurs with delayed evaporation of a less volatile component; however, the effect of the delay on ablation plume expansion remains virtually unexplored. Here, we have performed an experimental and theoretical study of the delayed evaporation effect using an example of a plume produced by nanosecond laser ablation of a gold–silver alloy in a vacuum and comparing it with ablation of pure gold and silver targets. The plume expansion dynamics are investigated by time-of-flight (TOF) mass spectrometry and direct simulation Monte Carlo (DSMC), while the laser-induced target evaporation is analyzed using a thermal model. A dramatic effect of the delay time on the average kinetic energy of the plume particles, especially for the less volatile gold, is demonstrated and the main collisional processes governing the two-component plume expansion under the conditions of delayed evaporation are revealed. Based on comparison of experimental and DSMC data, the delay of the gold evaporation onset is estimated as approximately 0.6 ns. The delayed evaporation is therefore an important factor for correct interpretation of TOF measurements in ablation plumes with components of different volatilities.

20 March 2015 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
Alexey A MorozovAlexey A Morozov
Alexey A Morozov
A theoretical study of the time-of-flight (TOF) distributions of neutral species produced by low-fluence pulsed laser evaporation in a vacuum has been performed. A database of TOF distributions has been calculated by the direct simulation Monte Carlo method. The calculated TOF signals have been fitted by a modification of the shifted Maxwell–Boltzmann distribution function with the only parameter being the shift velocity. The dependence of the shift velocity on the number of evaporated monolayers has been described by an analytical expression, derived based on the gas-dynamic analysis of pulsed gas expansion into a vacuum. This expression allows the derivation of a new formula for TOF distributions for neutral particles with the only parameter being the surface temperature. This new formula has been used for the analysis of experimental data on pulsed laser ablation of niobium, copper, graphite and gold. The evaluated surface temperature agrees well with the results of the thermal model calculations and available experimental data with an error of 10% instead of 50–150% for commonly used formulas.


1 November 2020 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
Alexey A MorozovAlexey A Morozov
Alexey A Morozov
AFA. A. Frolova
A. A. Frolova
Vladimir TitarevVladimir Titarev
Vladimir Titarev
The numerical study of one-dimensional gas expansion under pulsed evaporation into vacuum is carried out on the basis of the direct simulation Monte Carlo method, the exact Boltzmann kinetic equation, and the S-model kinetic equation. The results are presented for various levels of evaporation intensity, defined by the amount of evaporated material. Special attention has been paid to the calculation of the average axial energy of particles, the velocity vector of which deviates from the axis by no more than a small prescribed angle α. This characteristic of the flow is important for analysis of time-of-flight distributions in pulsed laser ablation. It is found that for intense evaporation, the average axial energy has a maximum as a function of time. The presented results allow us to establish the relative accuracy of the considered kinetic approaches for various flow regimes.