Till Höschen

Mr. Till Höschen

Max Planck Institute for Plasma Physics, Garching bei München, Bavaria, Germany
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2017 in Nuclear Fusion
Verified
Journal Article
Open access
PDF file
SBSebastijan Brezinsek
Sebastijan Brezinsek
Jan CoenenJan Coenen
Jan Coenen
TST. Schwarz-Selinger
T. Schwarz-Selinger
KSK. Schmid
K. Schmid
AKA. Kirschner
A. Kirschner
WCWp Pfc Contributors
Wp Pfc Contributors

1 August 2019 in Fusion Engineering and Design
Verified
Journal Article
Closed access
YMYiran Mao
Yiran Mao
CCC. Chen
C. Chen
Jan CoenenJan Coenen
Jan Coenen
JRJohann Riesch
Johann Riesch
SSS. Sistla
S. Sistla
CBCh. Broeckmann
Ch. Broeckmann

1 December 2018 in Journal of Nuclear Materials
Verified
Journal Article
Closed access
MLMuyuan Li
Muyuan Li
DRD. Ruprecht
D. Ruprecht
GKG. Kracker
G. Kracker
THTill Höschen
Till Höschen
RNRudolf Neu
Rudolf Neu

31 August 2017 in Physica Scripta
Verified
Journal Article
Closed access
PDF file
YMYiran Mao
Yiran Mao
Jan CoenenJan Coenen
Jan Coenen
JRJohann Riesch
Johann Riesch
SSS Sistla
S Sistla
JAJ Almanstötter
J Almanstötter
CBC Broeckmann
C Broeckmann

19 October 2017 in Physica Scripta
Verified
Journal Article
Closed access
PDF file
JRJohann Riesch
Johann Riesch
AFA Feichtmayer
A Feichtmayer
MFM Fuhr
M Fuhr
JAJ Almanstötter
J Almanstötter
Jan CoenenJan Coenen
Jan Coenen
RNRudolf Neu
Rudolf Neu

20 August 2015 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
LSL. Schiesko
L. Schiesko
GCG. Cartry
G. Cartry
CHC. Hopf
C. Hopf
THTill Höschen
Till Höschen
GMG. Meisl
G. Meisl
UFU. Fantz
U. Fantz
A study was conducted on the properties of molybdenum implanted with caesium as an approach to reduce the Cs consumption of negative hydrogen ion sources based on evaporated Cs. The depth profiles of the implanted Cs were simulated by SDTrimSP and experimentally determined by X-ray photoelectron spectroscopy depth profiling. In particular, one year after implantation, the depth profiles showed no signs of Cs diffusion into the molybdenum, suggesting long term stability of the implanted Cs atoms. The H− surface generation mechanisms on the implanted samples in hydrogen plasma were investigated, and the stability of the H− yield during four hours low power hydrogen plasma discharges was demonstrated. An estimation of the work function reduction (−0.8 eV) by the Cs implantation was performed, and a comparison of the relative negative ion yields between the implanted samples and highly oriented pyrolitic graphite showed that the Cs doped Mo negative ion yield was larger.