Kung-Bin Sung

Prof. Kung-Bin Sung

Auto-generated profile, based on publicly available information

Prof. Kung-Bin Sung


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2014 in Optics Letters
Verified
Journal Article
Closed access
PDF file
WHWei-Chen Hsu
Wei-Chen Hsu
JSJing-Wei Su
Jing-Wei Su
TTTe-Yu Tseng
Te-Yu Tseng
KSKung-Bin Sung
Kung-Bin Sung
We demonstrate a common-path tomographic diffractive microscopy technique for three-dimensional (3D) refractive-index (RI) imaging of unstained living cells. A diffraction grating is utilized to generate a reference beam that traverses a blank region of the sample in a common-path off-axis interferometry setup. Single-shot phase images captured at multiple illumination angles are used for 3D RI reconstruction based on optical diffraction tomography. The common-path configuration shows lower temporal phase fluctuations and better RI resolution than a Mach–Zehnder configuration. 3D subcellular RI distributions of live HeLa cells are quantified.

24 August 2012 in Journal of Biophotonics
Verified
Journal Article
Closed access
PDF file
JSJing‐Wei Su
Jing‐Wei Su
WHWei‐Chen Hsu
Wei‐Chen Hsu
CCCheng-Ying Chou
Cheng-Ying Chou
CCChen‐Hao Chang
Chen‐Hao Chang
KSKung‐Bin Sung
Kung‐Bin Sung

21 April 2022 in Biomedical Optics Express
Verified
Journal Article
Closed access
AAAli Afshari
Ali Afshari
RSRolf B. Saager
Rolf B. Saager
DBDavid Burgos
David Burgos
WVWilliam C. Vogt
William C. Vogt
JWJianting Wang
Jianting Wang
JPJoshua Pfefer
Joshua Pfefer
Clinical studies have demonstrated that epidermal pigmentation level can affect cerebral oximetry measurements. To evaluate the robustness of these devices, we have developed a phantom-based test method that includes an epidermis-simulating layer with several melanin concentrations and a 3D-printed cerebrovascular module. Measurements were performed with neonatal, pediatric and adult sensors from two commercial oximeters, where neonatal probes had shorter source-detector separation distances. Referenced blood oxygenation levels ranged from 30 to 90%. Cerebral oximeter outputs exhibited a consistent decrease in saturation level with simulated melanin content; this effect was greatest at low saturation levels, producing a change of up to 15%. Dependence on pigmentation was strongest in a neonatal sensor, possibly due to its high reflectivity. Overall, our findings indicate that a modular channel-array phantom approach can provide a practical tool for assessing the impact of skin pigmentation on cerebral oximeter performance and that modifications to algorithms and/or instrumentation may be needed to mitigate pigmentation bias.

16 March 2011 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
TTTe-Yu Tseng
Te-Yu Tseng
CCChun-Yu Chen
Chun-Yu Chen
YLYi-Shan Li
Yi-Shan Li
KSKung-Bin Sung
Kung-Bin Sung
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

7 March 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
STSheng-Yang Tsui
Sheng-Yang Tsui
CWChiao-Yi Wang
Chiao-Yi Wang
THTsan-Hsueh Huang
Tsan-Hsueh Huang
KSKung-Bin Sung
Kung-Bin Sung
A robust modelling method was proposed to extract chromophore information in multi-layered skin tissue with spatially-resolved diffuse reflectance spectroscopy. Artificial neural network models trained with a pre-simulated database were first built to map geometric and optical parameters into diffuse reflectance spectra. Nine fitting parameters including chromophore concentrations and oxygen saturation were then determined by solving the inverse problem of fitting spectral measurements from three different parts of the skin. Compared to the Monte Carlo simulation accelerated by a graphics processing unit, the proposed modelling method not only reduced the computation time, but also achieved a better fitting performance.

13 November 2020 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
YLYang-Hsien Lin
Yang-Hsien Lin
KLKen Y.-K. Liao
Ken Y.-K. Liao
KSKung-Bin Sung
Kung-Bin Sung
Information about red blood cell (RBC) morphology is crucial to reach a diagnosis of blood disorders because RBC morphologies often change due to altered membrane lipid composition, iron deficiency, or metabolic abnormalities.1,2 The current diagnostic procedure for many blood-related diseases is the blood smear test in which the morphology of stained RBCs is examined under a light microscope. Staining of the blood film is usually required to achieve adequate image contrast for proper microscopic examination. However, the staining process is time-consuming and may cause variations in the resulting contrast, both of which impede the blood smear test to be used as an automatic and high-throughput procedure.3