Established medical imaging technologies such as magnetic resonance imaging and computed tomography rely on well-validated tissue-simulating phantoms for standardized testing of device image quality. The availability of high-quality phantoms for optical-acoustic diagnostics such as photoacoustic tomography (PAT) will facilitate standardization and clinical translation of these emerging approaches. Materials used in prior PAT phantoms do not provide a suitable combination of long-term stability and realistic acoustic and optical properties. Therefore, we have investigated the use of custom polyvinyl chloride plastisol (PVCP) formulations for imaging phantoms and identified a dual-plasticizer approach that provides biologically relevant ranges of relevant properties. Speed of sound and acoustic attenuation were determined over a frequency range of 4 to 9 MHz and optical absorption and scattering over a wavelength range of 400 to 1100 nm. We present characterization of several PVCP formulations, including one designed to mimic breast tissue. This material is used to construct a phantom comprised of an array of cylindrical, hemoglobin-filled inclusions for evaluation of penetration depth. Measurements with a custom near-infrared PAT imager provide quantitative and qualitative comparisons of phantom and tissue images. Results indicate that our PVCP material is uniquely suitable for PAT system image quality evaluation and may provide a practical tool for device validation and intercomparison.

1 January 2006 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
AAAnant Agrawal
Anant Agrawal
SHStanley Huang
Stanley Huang
ALAlex Wei Haw Lin
Alex Wei Haw Lin
MLMin-Ho Lee
Min-Ho Lee
JBJennifer K. Barton
Jennifer K. Barton
JPJoshua Pfefer
Joshua Pfefer
Nanoshell-enhanced optical coherence tomography (OCT) is a novel technique with the potential for molecular imaging and improved disease detection. However, optimization of this approach will require a quantitative understanding of the influence of nanoshell parameters on detected OCT signals. In this study, OCT was performed at 1310nm in water and turbid tissue-simulating phantoms to which nanoshells were added. The effect of nanoshell concentration, core diameter, and shell thickness on signal enhancement was characterized. Experimental results indicated trends that were consistent with predicted optical properties—a monotonic increase in signal intensity and attenuation with increasing shell and core size. Threshold concentrations for a 2-dB OCT signal intensity gain were determined for several nanoshell geometries. For the most highly backscattering nanoshells tested—291-nm core diameter, 25-nm shell thickness—a concentration of 109 nanoshells/mL was needed to produce this signal increase. Based on these results, we discuss various practical considerations for optimizing nanoshell-enhanced OCT. Quantitative experimental data presented here will facilitate optimization of OCT-based diagnostics and may also be relevant to other reflectance-based approaches as well.

16 September 2013 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
JBJigesh Baxi
Jigesh Baxi
WCWilliam Calhoun
William Calhoun
YSYasir Jamal Sepah
Yasir Jamal Sepah
DHDaniel Xavier Hammer
Daniel Xavier Hammer
IIIlko Ilev
Ilko Ilev
AAAnant Agrawal
Anant Agrawal
Optical coherence tomography (OCT) is a rapidly growing imaging modality, particularly in the field of ophthalmology. Accurate early diagnosis of diseases requires consistent and validated imaging performance. In contrast to more well-established medical imaging modalities, no standardized test methods currently exist for OCT quality assurance. We developed a retinal phantom which mimics the thickness and near-infrared optical properties of each anatomical retinal layer as well as the surface topography of the foveal pit. The fabrication process involves layer-by-layer spin coating of nanoparticle-embedded silicone films followed by laser micro-etching to modify the surface topography. The thickness of each layer and dimensions of the foveal pit are measured with high precision. The phantom is embedded into a commercially available, water-filled model eye to simulate ocular dispersion and emmetropic refraction, and for ease of use with clinical OCT systems. The phantom was imaged with research and clinical OCT systems to assess image quality and software accuracy. Our results indicate that this phantom may serve as a useful tool to evaluate and standardize OCT performance.

1 January 2003 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
JPJoshua Pfefer
Joshua Pfefer
LML. Stephanie Matchette
L. Stephanie Matchette
CBCarrie L. Bennett
Carrie L. Bennett
JGJessica A. Gall
Jessica A. Gall
JWJoy N. Wilke
Joy N. Wilke
MEMarwood N. Ediger
Marwood N. Ediger
Accurate data on in vivo tissue optical properties in the ultraviolet A (UVA) to visible (VIS) range are needed to elucidate light propagation effects and to aid in identifying safe exposure limits for biomedical optical spectroscopy. We have performed a preliminary study toward the development of a diffuse reflectance system with maximum fiber separation distance of less than 2.5 mm. The ultimate objective is to perform endoscopic measurement of optical properties in the UVA to VIS. Optical property sets with uniformly and randomly distributed values were developed within the range of interest: absorption coefficients from 1 to 25 cm−1 and reduced scattering coefficients from 5 to 25 cm−1. Reflectance datasets were generated by direct measurement of Intralipid-dye tissue phantoms at λ=675 nm and Monte Carlo simulation of light propagation. Multivariate calibration models were generated using feed-forward artificial neural network or partial least squares algorithms. Models were calibrated and evaluated using simulated or measured reflectance datasets. The most accurate models developed—those based on a neural network and uniform optical property intervals—were able to determine absorption and reduced scattering coefficients with root mean square errors of ±2 and ±3 cm−1, respectively. Measurements of ex vivo bovine liver at 543 and 633 nm were within 5 to 30% of values reported in the literature. While our technique for determination of optical properties appears feasible and moderately accurate, enhanced accuracy may be achieved through modification of the experimental system and processing algorithms. © 2003 Society of Photo-Optical Instrumentation Engineers.

11 July 2024 in Communications Medicine
Verified
Journal Article
Open access
PDF file
SVSandhya Vasudevan
Sandhya Vasudevan
WVWilliam C. Vogt
William C. Vogt
SWSandy Weininger
Sandy Weininger
JPJoshua Pfefer
Joshua Pfefer
Pulse oximetry enables real-time, noninvasive monitoring of arterial blood oxygen levels. However, results can vary with skin color, thus detecting disparities during clinical validation studies requires an accurate measure of skin pigmentation. Recent clinical studies have used subjective methods such as self-reported color, race/ethnicity to categorize skin. Melanometers based on optical reflectance may offer a more effective, objective approach to assess pigmentation. Here, we review melanometry approaches and assess evidence supporting their use as clinical research tools. We compare performance data, including repeatability, robustness to confounders, and compare devices to each other, to subjective methods, and high-quality references. Finally, we propose best practices for evaluating melanometers and discuss alternate optical approaches that may improve accuracy. Whilst evidence indicates that melanometers can provide superior performance to subjective approaches, we encourage additional research and standardization efforts, as these are needed to ensure consistent and reliable results in clinical studies.

21 May 2020 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
ARAlberto J. Ruiz
Alberto J. Ruiz
MWMindy Wu
Mindy Wu
ELEthan Philip M. LaRochelle
Ethan Philip M. LaRochelle
DGDimitris Gorpas
Dimitris Gorpas
VNVasilis Ntziachristos
Vasilis Ntziachristos
BPBrian W. Pogue
Brian W. Pogue
Fluorescence imaging in surgery allows for visualization of biologically relevant markers that are indicated to guide rapid decision-making during the procedure.1 – 3 The use of fluorescence-guided surgery (FGS) has been growing at a steady pace over the past 70 years, with rapid expansion over the last decade as the imaging technologies have matured to enable seamless integration into the clinical workflow.2 Indocyanine green (ICG) is by far the most widely used tissue perfusion agent and cardiac flow indicator within FGS.4 The success of ICG within fluorescence imaging can be attributed to its absorption and emission in the near-infrared (NIR) range, its low toxicity, and its history of use within medicine for over half a century.2,4 – 6 As the field of FGS expands, there is a wider range of imaging systems that are indicated for the same uses, such that there is a compelling need for standards that enable system characterization, performance monitoring, and intersystem comparisons or calibration.7 – 10 The performance of imaging systems can affect surgical decision making,7 so knowledge of their performance capabilities is especially relevant given the real-time decisions that are made with these systems during surgical procedures.