The Latarjet procedure is a common bony augmentation procedure for anterior shoulder instability. Historically, screw fixation is used to secure the coracoid graft to the anterior glenoid surface; however, malpositioning of the graft leads to oblique screw insertion that contributes to complications. Suture buttons (SBs) are a more recent fixation technique that have not been studied alongside standard screw fixation in the context of biomechanical models of angulated fixation. This study aims to compare the biomechanical strength of single and double, screw and SB fixation at various levels of angulation. Testing was performed using polyurethane models from Sawbones. The graft piece was secured with screw fixation (Arthrex, Naples, FL, USA) or suspensory button (ABS Tightrope, Arthrex, Naples, FL, USA). Single or double constructs of screws and SBs were affixed at 0°, 15°, and 30° angles to the face of the glenoid component. An aluminum testing jig held the samples securely while a materials testing system applied loads. Five constructs were used for each condition and assessed load to failure testing. For single fixation constructs, suspensory buttons were 60% stronger than screws at 0° (P < .001), and 52% stronger at 15° (P = .004); however, at 30°, both were comparable (P = .180). Interestingly, single suspensory button at 15° was equivalent to a single screw at 0° (P = .310). For double fixation, suspensory buttons (DT) were 32% stronger than screws at 0° (P < .001) and 35% stronger than screws at 15° (P < .001). Both double fixation methods were comparable at 30° (P = .061). Suspensory buttons at 15° and 30° were equivalent to double screws at 0 (P = .280) and 15° (P = .772), respectively. These measurements indicate that the suspensory button has a significantly higher load to failure capacity over the screw fixation technique, perpendicularly and with up to 15° of angulation. These analyses also indicate that the suspensory button fixation offers superior strength even when positioned more obliquely than the screw fixation. Therefore, suspensory button fixation may confer more strength while offering greater margin for error when positioning the graft.
Introduction: Orthopaedic surgery is one of the most competitive and least diverse specialties in medicine. Affiliation of an orthopaedics with an allopathic medical school impacts research opportunities and early exposure to clinical orthopaedics. The purpose of this study is to examine the potential effect allopathic medical school affiliation has on orthopaedic surgery resident demographics and academic characteristics. Methods: All 202 Accreditation Council for Graduate Medical Education (ACGME)-accredited orthopaedics programs were divided into 2 groups: Group 1 consisted of residency programs without an affiliated allopathic medical school, and Group 2 consisted of programs with an affiliated allopathic medical school. Affiliations were determined by cross-referencing the ACGME residency program list with the medical school list published by Association of American Medical Colleges (AAMC). Program and resident characteristics were then compiled using AAMC’s Residency Explorer including region, program setting, number of residents, and osteopathic recognition. Resident characteristics included race, gender, experiences (work, volunteer, and research), peer-reviewed publications, and US Medical Licensing Examination Step 1 scores. Results: Of the 202 ACGME-accredited orthopaedics residencies, Group 1 had 61 (30.2%) programs, and Group 2 had 141 (69.8%) programs. Group 2 had larger programs (4.9 vs. 3.2 resident positions/year; p < 0.001) and 1.7 times the number of residency applicants (655.8 vs. 385.5; p < 0.001). Most Group 2 residents were allopathic medical school graduates, 95.5%, compared with 41.6% in Group 1. Group 1 had 57.0% osteopathic medical school graduates, compared with 2.9% in Group 2. There were 6.1% more White residents in Group 1 residencies (p = 0.025), and Group 2 residencies consisted of 3.5% more Black residents in relation to Group 1 (p = 0.03). Academic performance metrics were comparable between the 2 groups (p > 0.05). Conclusion: This study demonstrated that candidates who successfully match into an orthopaedic surgery residency program achieve high academic performance, regardless of whether the program was affiliated with an allopathic medical school. Differences may be influenced by increased representation of minority faculty, greater demand for allopathic residents, or stronger emphasis on promotion of diversity in those residency programs. Availability of Data and Material: Available on reasonable request. Level of Evidence: Level III. See Instructions for Authors for a complete description of levels of evidence.
Purpose: The purpose of this study is to quantify the difference in biomechanical stability of suture button (SB) and suture tape cerclage (STC) constructs with hand tensioning versus device tensioning of anterior glenoid augmentation bone grafts in an anterior glenoid bone loss model. Methods: Artificial bone blocks with a density of 15 lb/ft3 (240.3 kg/m3) were used as models for glenoid fixation with bone graft. The biomechanical stability of SB and STC tensioned by hand was compared to those tensioned by a device. Average displacement (mm) following application of various forces (50, 100, 150, and 200 N) during a 7-phase, 100-cycle, stairstep cyclic loading protocol was recorded. Results: Both SB and STC fixation displayed significantly lower construct displacement at all tested forces when tensioned with a device versus hand ( p < 0.001). Device-tensioned SB and STC were comparable in construct stability at forces below 100N. However, at forces above 100 N, device-tensioned SB exhibited significantly less displacement than device-tensioned STC. Discussion: Using a tensioning device for SB or STC fixation of a coracoid graft model results in less displacement and improved stability compared to hand tensioning. Biomechanically, a tensioning device enhances the stability of suture fixation in glenoid bone graft constructs.
Background: The risk of venous thromboembolic events (VTE) increases in patients undergoing total shoulder arthroplasty (TSA). However, there is no guidelines for prophylaxis. A decreased ratio of ADAMTS13 to VWF has been reported in patients with VTE. This study evaluates how TSA affects this ratio to better characterize timing of VTE risk and develop better guidelines for prophylactic treatment. Methods: Patients receiving TSA between 2016 and 2019 were recruited for this study following informed consent. Blood samples were collected at the clinic visit prior to surgery, postoperatively within one hour, at 24 h, 48 h, 2 and 6 weeks. Plasma levels of ADAMTS13 activity and VWF antigen were determined with a FRETS-VWF73 and an enzyme-linked immunoassay, respectively. Results: Of 22 patients included in the study, the mean age (± SD) was 68 ± 11 years. The most common diagnosis and surgery were osteoarthritis (68%) and reverse TSA (77%), respectively. Plasma ADAMTS13 activity was reduced immediately following surgery and remained lower than the baseline until postoperative day 2 (POD-2) (93.7 ± 28.5 IU/dL, p = 0.009). VWF antigen was the highest on POD-2 (253.2 ± 101.0%, p = 0.0034). The ADAMTS13/VWF ratio followed the same pattern, lowest on POD-2 (0.41 ± 0.20, p = 0.0016). All levels returned to baseline by two weeks. Conclusions: TSA resulted in low ADAMTS13 activity and high VWF acutely post-surgery day 2, suggesting that risk for VTE may be the highest during this period. ADAMTS13/VWF ratio is a useful marker to identify patients who may need proper anticoagulation after TSA.
1 July 2023 in Orthopaedic Journal of Sports Medicine
Objectives: The greater tuberosity notch (GTN) is an uncommonly reported radiographic finding which has been associated with articular sided partial rotator cuff tears (RCTs) in throwing athletes. This finding has yet to be evaluated in patients with degenerative tears. The purpose of this study is to assess the GTN measurement along with five other previously described radiographic indicators for degenerative RTCs. Methods: After obtaining IRB approval, we prospectively collected and compared 80 standard shoulder radiograph series with an additional “notch view”, a lateral oblique radiograph showing the greater tuberosity in profile. Thirty-four patients had confirmed rotator cuff tears confirmed via arthroscopy and 46 control patients did not have suspected rotator cuff pathology. Two musculoskeletal radiologists independently reviewed radiographs for GTN size and five previously described radiographic indicators of RCTs including: greater tuberosity cyst (GTC), acromiohumeral interval (AHI), critical shoulder angle (CSA), inferior acromial sclerosis (IAS), and lateral acromial spurring (LAS). A receiver operator characteristic (ROC) curve was performed to compare the individual performance of each of the six radiographic markers. Nearest neighbor analysis based on Euclidean distances followed by clustering described the pattern of radiographic variables occurring together in the setting of a RCT. Results: A total of 320 radiographs were reviewed and 1920 measurements were made. RCTs were independently associated with IAS, LAS, GTCs, decreased AHI and large GTNs (P < 0.01), but not the CSA or smaller notch sizes. Overall, the GTN size predicted a RCT with moderate accuracy (AUC=0.676). Cluster analysis suggested the AHI has the strongest correlation with RCTs and is the most closely related to the GTN size (P < 0.003) compared to other indicators based on Euclidean distances. Conclusions: The presence of a medium-sized greater tuberosity notch alone is moderately sensitive for detecting a degenerative RCT. Additionally, the presence of at least one other indicator on radiographs dramatically increases the likelihood of finding a RCT during surgery. The size and presence of these radiographic markers in combination may represent a continuum of increasing severity of cuff pathology.