Jenan Abuqadourah

Dr. Jenan Abuqadourah

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

5 March 2022 in City, Territory and Architecture
Verified
Journal Article
Open access
PDF file
JAJenan Abuqadourah
Jenan Abuqadourah
AAAla’a M. Al-Falahat
Ala’a M. Al-Falahat
SASaad S. Alrwashdeh
Saad S. Alrwashdeh
CNChristoph Nytsch‐Geusen
Christoph Nytsch‐Geusen
In this paper, the possibility of reducing the energy demand of the typical multi-family buildings in Amman, Jordan utilizing passive design strategies are investigated through a parametric simulation study. Firstly, the energy demand of the multi-family buildings under the typical practice is evaluated, after that several design strategies are proposed such as wall and roof insulation, shading device, ventilation, etc. The effect of each strategy on the multi-family buildings’ energy demands is assessed alone and then in combination with the other strategies, to find the optimum solution to reduce the energy demand. This is beneficial for architects, engineers, and decisions makers involved in the design of energy-efficient multifamily buildings. The result proves that it’s possible to reduce the annual energy demand by 53, 71, and 78% of the cooling, heating, and lighting, respectively, by introducing passive design strategies. Around 45% savings of the heating demand are achieved due to adding wall insulation. Regarding the cooling demand about 17%, and 14% are saved due to applying a ventilated blind shading device and using a nighttime ventilation strategy.


2 June 2022 in Cogent Engineering
Verified
Journal Article
Open access
JAJenan Abuqadourah
Jenan Abuqadourah
AAAla’A M. Al-Falahat
Ala’A M. Al-Falahat
SASaad S. Alrwashdeh
Saad S. Alrwashdeh
Photovoltaic energy-generating has attracted widespread attention, because of its efficiency and environmental benefits. As the number of buildings floors increases, the area of the façade grows substantially larger than the roof, which led to increasing the potential for a solar system installed on the vertical walls, although they receive less solar radiation than roof surfaces. As a result, it has become critical to assess the solar installation possibilities on buildings’ roofs as well as facades in the early design stage. Accordingly, the aim of this paper is to present a method to evaluate the suitable area on the building surfaces for photovoltaic installation, taking Apartment buildings in Amman, Jordan as a case study. The methodology is based on the assessment of the incident solar radiation on different surfaces, considering the shading effect from surrounding buildings in the most common residential urban zone in Jordan, and architectural suitable areas for PV installation. Different simulation software was used, Autodesk Ecotect simulation software was used to calculate the incident solar radiation on the building surfaces and IDA ICE 4.8 simulation software to predict the overshadowing area. The main findings of this study show that conducting a solar potential in the early design stage is critical to defining the most suitable surfaces for PV installation. Moreover, the highest potential envelope part of installing the solar photovoltaic technologies is the roof because it is unshaded and received the highest solar radiation, followed by the south façade with about 40% less received solar radiation. This study can contribute to supporting energy and urban planners in determining the best locations for solar photovoltaic installations on building surfaces.

1 January 2022 in Journal of Applied Engineering Science
Verified
Journal Article
Open access
PDF file
JAJenan Abuqadourah
Jenan Abuqadourah
AAAla'A Al-Falahat
Ala'A Al-Falahat
SASaad Alrwashdeh
Saad Alrwashdeh
This paper evaluates and compares the embodied energy and embodied carbon using a Life Cycle Assessment (LCA) approach for three different intermediate floor structures, all of which use prefabricated materials-cross-laminated timber (CLT), precast hollow-core concrete, and solid concrete-to decide which floor construction materials have less environmental impact for use in the construction of a semi-detached house in the UK. The Inventory of Carbon & Energy (ICE) and the Carbon Calculator tool were used to calculate the carbon footprint from "cradle to grave" to determine whether the use of a CLT solution provides improved environmental performance over the traditional concrete solutions. The carbon footprint results indicate that the use of a hollow-core precast concrete floor system emits less carbon than the other two systems, although the concrete requires more fossil fuel input than the timber during the manufacturing process, so based on this, the footprint from cradle to gate for the timber was expected to be the less than that of the concrete. However, the results show the opposite; this is because of the differences in the material quantities needed in each system.

3 June 2024 in Architectural Engineering and Design Management
Verified
Journal Article
Closed access
SASaba Alnusairat
Saba Alnusairat
JAJenan Abuqadourah
Jenan Abuqadourah