Win Ken Beh

Mr. Win Ken Beh

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2021 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
WBWin Ken Beh
Win Ken Beh
YWYi-Hsuan Wu
Yi-Hsuan Wu
AWAn-Yeu (Andy) Wu
An-Yeu (Andy) Wu
Heart rate variability (HRV) has been used in assessing mental workload(MW) level. Compared with ECG, photoplethysmogram (PPG) provides convenient in assessing MW with wearable devices, which is more suitable for daily usage. However, PPG collected by smartwatches are prone to suffer from artifacts. Those signal corruptions cause invalid Inter-beat Intervals (IBI), making it challenging to evaluate the HRV feature. Hence, the PPG-based MW assessment system is difficult to obtain a sustainable and reliable assessment of MW. In this paper, we propose a pre- and post- processing technique, called outlier removal and uncertainty estimation, respectively, to reduce the negative influences of invalid IBIs. The proposed method helps to acquire accurate HRV features and evaluate the reliability of incoming IBIs, rejecting possibly misclassified data. We verified our approach in two open datasets, which are CLAS and MAUS. Experiment results show proposed method achieved higher accuracy (66.7% v.s. 74.2%) and lower variance (11.3% v.s. 10.8%) among users, which has comparable performance to an ECG-based MW system.

29 June 2022 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
YCYi-Ta Chen
Yi-Ta Chen
HLHsing-Hao Lee
Hsing-Hao Lee
CSChing-Yen Shih
Ching-Yen Shih
ZCZih-Ling Chen
Zih-Ling Chen
WBWin Ken Beh
Win Ken Beh
AWAn-Yeu (Andy) Wu
An-Yeu (Andy) Wu
Mind-wandering (MW), which is usually defined as a lapse of attention has negative effects on our daily life. Therefore, detecting when MW occurs can prevent us from those negative outcomes resulting from MW. In this work, we first collected a multi-modal Sustained Attention to Response Task (MM-SART) database for MW detection. Eighty-two participants’ data were collected in our dataset. For each participant, we collected measures of 32-channels electroencephalogram (EEG) signals, photoplethysmography (PPG) signals, galvanic skin response (GSR) signals, eye tracker signals, and several questionnaires for detailed analyses. Then, we propose an effective MW detection system based on the collected EEG signals. To explore the non-linear characteristics of the EEG signals, we utilize entropy-based features. The experimental results show that we can reach 0.712 AUC score by using the random forest (RF) classifier with the leave-one-subject-out cross-validation. Moreover, to lower the overall computational complexity of the MW detection system, we propose correlation importance feature elimination (CIFE) along with AUC-based channel selection. By using two most significant EEG channels, we can reduce the training time of the classifier by 44.16%. By applying CIFE on the feature set, we can further improve the AUC score to 0.725 but with only 14.6% of the selection time compared with the recursive feature elimination (RFE). Finally, we can apply the current work to educational scenarios nowadays, especially in remote learning systems.

18 April 2023 in ACM Transactions on Computing for Healthcare
Verified
Journal Article
Open access
WBWin Ken Beh
Win Ken Beh
YYYu-Chia Yang
Yu-Chia Yang
YLYi-Cheng Lo
Yi-Cheng Lo
YLYun-Chieh Lee
Yun-Chieh Lee
AWAn-Yeu (Andy) Wu
An-Yeu (Andy) Wu
Photoplethysmography (PPG) is a non-invasive technique for recording human vital signs. PPG is normally recorded by wearable devices that are prone to artifacts. This results in signal corruption that decreases measurement accuracy. Thus, a signal quality assessment (SQA) system is essential in obtaining reliable measurements. Conventionally, SQA is mainly driven by human-knowledge and supervised through experts’ annotations. However, they are not tailored for the particularities of the domain applications. Hence, we propose a machine-aided SQA framework that generates respective quality criteria for applications. By using the proposed approach, quality criteria can be easily trained for different applications. Then, quality assessment can be applied to several PPG-based physiological signals telemonitoring. Compared with conventional approaches, the proposed system has a higher rejection rate for high-error signals and a lower mean absolute error is achieved when estimating heart rate (-3.06 BPM), determining respiration rate (–1.36 BPM), and predicting hypertension (+24%). The proposed method enhances accuracy in monitoring physiological signals and thus is suitable for healthcare applications.

16 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
WBWin Ken Beh
Win Ken Beh
YYYu-Chia Yang
Yu-Chia Yang
AWAn-Yeu (Andy) Wu
An-Yeu (Andy) Wu
Photoplethysmography (PPG) is widely utilized in wearable healthcare devices due to its convenient measurement capabilities. However, the unrestricted behavior of users often introduces artifacts into the PPG signal. As a result, signal processing and quality assessment play a crucial role in ensuring that the information contained in the signal can be effectively acquired and analyzed. Traditionally, researchers have discussed signal quality and processing algorithms separately, with individual algorithms developed to address specific artifacts. In this paper, we propose a quality-aware signal processing mechanism that evaluates incoming PPG signals using the signal quality index (SQI) and selects the appropriate processing method based on the SQI. Unlike conventional processing approaches, our proposed mechanism recommends processing algorithms based on the quality of each signal, offering an alternative option for designing signal processing flows. Furthermore, our mechanism achieves a favorable trade-off between accuracy and energy consumption, which are the key considerations in long-term heart rate monitoring.

17 April 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
WBWin Ken Beh
Win Ken Beh
YYYu-Chia Yang
Yu-Chia Yang
AWAn-Yeu (Andy) Wu
An-Yeu (Andy) Wu
Photoplethysmography (PPG) is widely utilized in wearable healthcare devices due to its convenient measurement capabilities. However, the unrestricted behavior of users often introduces artifacts into the PPG signal. As a result, signal processing and quality assessment play a crucial role in ensuring that the information contained in the signal can be effectively acquired and analyzed. Traditionally, researchers have discussed signal quality and processing algorithms separately, with individual algorithms developed to address specific artifacts. In this paper, we propose a quality-aware signal processing mechanism that evaluates incoming PPG signals using signal quality index (SQI) and selects the appropriate processing method based on the SQI. Unlike conventional processing approaches, our proposed mechanism recommends processing algorithms based on the quality of each signal, offering an alternative option for designing signal processing flows. Furthermore, our mechanism achieves a favorable trade-off between accuracy and energy consumption, which are the key considerations in long-term heart rate monitoring.

18 August 2022 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
YLYi-Cheng Lo
Yi-Cheng Lo
WBWin Ken Beh
Win Ken Beh
CHChiao-Chun Huang
Chiao-Chun Huang
AWAn-Yeu (Andy) Wu
An-Yeu (Andy) Wu
Compressed sensing (CS) has drawn much attention in electrocardiography (ECG) signal monitoring for its effectiveness in reducing the transmission power of wireless sensor systems. Compressed analysis (CA) is an improved methodology to further elevate the system's efficiency by directly performing classification on the compressed data at the back-end of the monitoring system. However, conventional CA lacks of considering the effect of noise, which is an essential issue in practical applications. In this work, we observe that noise causes an accuracy drop in the previous CA framework, thus discovering that different signal-to-noise ratios (SNRs) require different sizes of CA models. We propose a two-stage noise-level aware compressed analysis framework. First, we apply the singular value decomposition to estimate the noise level in the compressed domain by projecting the received signal into the null space of the compressed ECG signal. A transfer-learning-aided algorithm is proposed to reduce the long-training-time drawback. Second, we select the optimal CA model dynamically based on the estimated SNR. The CA model will use a predictive dictionary to extract features from the ECG signal, and then imposes a linear classifier for classification. A weight-sharing training mechanism is proposed to enable parameter sharing among the pre-trained models, thus significantly reducing storage overhead. Lastly, we validate our framework on the atrial fibrillation ECG signal detection on the NTUH and MIT-BIH datasets. We show improvement in the accuracy of 6.4% and 7.7% in the low SNR condition over the state-of-the-art CA framework.