Fangxiao Cui

Dr. Fangxiao Cui

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2020 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
DLDacheng Li
Dacheng Li
FCFangxiao Cui
Fangxiao Cui
AWAnjing Wang
Anjing Wang
YLYangyu Li
Yangyu Li
JWJun Wu
Jun Wu
YQYanli Qiao
Yanli Qiao
Longwave infrared (LWIR) spectroscopy is useful for detecting and identifying hazardous clouds by passive remote sensing technology. Gaseous constituents are usually assumed to be thin plumes in a three-layer model, from which the spectral signatures are linearly superimposed on the brightness temperature spectrum. However, the thin-plume model performs poorly in cases of thick clouds. A modification to this method is made using synthetic references as target spectra, which allow linear models to be used for thick clouds. The prior background, which is generally unknown in most applications, is reconstructed through a regression method using predefined references. However, large residuals caused by fitting errors may distort the extracted spectral signatures and identification results if the predefined references are not consistent with the real spectral shapes. A group of references are generated to represent the possible spectral shapes, and the least absolute shrinkage and selection operator (LASSO) method is used to select the most appropriate reference for spectral fitting. Small residuals and adaptive identification are achieved by automatically selecting the reference spectrum. Two experiments are performed to verify the algorithm proposed in this article. Ethylene is adaptively detected during an indoor release process, and the spectral shape varies with the amount released. In addition, ammonia is measured under different humidity conditions, and the background is adaptively removed using the LASSO method. Based on this research, LWIR remote sensing technology can be applied in various target-detection scenarios, and adaptive identification is achieved to promote hazardous cloud detection.

12 December 2022 in Optics
Verified
Journal Article
Open access
PDF file
FCFangxiao Cui
Fangxiao Cui
YZYue Zhao
Yue Zhao
AWAn-jing Wang
An-jing Wang
FMFeng-Xiang Ma
Feng-Xiang Ma
JWJun Wu
Jun Wu
WDWang-Chao Dong
Wang-Chao Dong
Gas remote detection is useful for early warning of gas leakage and toxic chemicals. Optical gas imaging (OGI) built with an uncooled infrared camera is superior to cooled detectors in terms of cost. Current mainstream OGI technologies fall short in their detection of gases at ambient temperature and their ability to classify multiple gases. A multi-spectral uncooled imager is developed to try to solve these problems, which is constructed from a commercial uncooled thermal camera and wide band filters. To solve filter self-radiation and unevenness, a correction method is devised, with an ambient temperature blackbody placed in front and subtracted from the measured image. Based on waveband cutoffs, filters are classified into target-sensitive filters and background filters. Multi-spectra are simulated according to wide band filter transmittance, which can be used in gas classification. A sulfur hexafluoride (SF6) experiment is conducted outdoors at a distance of 10 m. An SVM model is trained to classify gas release in real time. Detection with a cold sky background is improved with the aid of data cube differences in a time sequence. The SF6 outdoor experiment concluded with preliminary effective results of ambient temperature gas remote detection.

2 October 2025 in Optics Express
Verified
Journal Article
Closed access
WLWei Luo
Wei Luo
SYSong Ye
Song Ye
WXWei Xiong
Wei Xiong
ZZZiyang Zhang
Ziyang Zhang
BDBaijun Dong
Baijun Dong
FWFangyuan Wang
Fangyuan Wang
The spatial heterodyne spectrometer may be affected by noise during detection, causing target spectral features to be obscured and preventing the acquisition of required information. Therefore, effective methods are needed to reduce the impact of noise on spatial heterodyne interferograms. For spatial heterodyne interferograms with the same type of detection targets and highly similar interference information in each row, a denoising method based on a convolutional encoder-decoder and transformer is proposed, and the method is trained and tested using real data from the GF-5 satellite. Experimental results show that the method can effectively denoise the interferogram and then improve spectral data quality, while demonstrating superior denoising performance compared to other algorithms. Finally, the trained model is used to denoise interferograms with real noise from GF-5 data, showing good denoising effectiveness. This work has study significance and application value in reducing the impact of noise on spatial heterodyne spectral information and achieving high-precision remote sensing detection of targets.

5 January 2026 in Remote Sensing
Verified
Journal Article
Open access
PDF file
LYLi Yunze
Li Yunze
JWJun Wu
Jun Wu
Wei XiongWei Xiong
Wei Xiong
DLDacheng Li
Dacheng Li
YLYangyu Li
Yangyu Li
FCFangxiao Cui
Fangxiao Cui
Fourier transform infrared (FTIR) spectroscopy-based gas remote sensing has been widely applied for long-range atmospheric composition analysis. However, when deployed for longwave infrared methane detection, spectral features of methane are significantly interfered by water vapor variations at the edge of atmospheric window, which compromises detection performance. To address the spectral fitting degradation caused by relative changes between methane and water vapor signals, this study incorporates temperature, relative humidity, and sensing distance into the cost function, establishing a continuous optimization space with concentration path lengths (CLs) as variables, which are the product of the concentration and path length. A hybrid differential evolution and Levenberg–Marquardt (D-LM) algorithm is developed to enhance parameter estimation accuracy. Combined with a three-layer atmospheric model for real-time reference spectrum generation, the algorithm identifies the optimal spectral combination that provides the best match to the measured data. Algorithm performance is validated through two experimental configurations: Firstly, adaptive detection using synthetic spectra covering various humidity–methane concentration combinations is conducted; simulation results demonstrate that the proposed method significantly reduces the mean squared error (MSE) of fitting residuals by 95.8% compared to the traditional LASSO method, effectively enhancing methane spectral feature extraction under high-water-vapor conditions. Then, a continuous monitoring of controlled methane releases over a 500 m open path under high-outdoor-humidity conditions is carried out to validate outdoor performance of the proposed algorithm; field measurement analysis further confirms the method’s robustness, achieving a reduction in fitting residuals of approximately 57% and improving spectral structure fitting. The proposed approach provides a reliable technical pathway for adaptive gas cloud detection under complex atmospheric conditions.