Mohd Mawardi Saari

Dr. Mohd Mawardi Saari

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2024 in Journal of Building Engineering
Verified
Journal Article
Closed access
Mohd Herwan SulaimanMohd Herwan Sulaiman
Mohd Herwan Sulaiman
ZMZuriani Mustaffa
Zuriani Mustaffa
MSMuhammad Salihin Saealal
Muhammad Salihin Saealal
MSMohd Mawardi Saari
Mohd Mawardi Saari
AAAbu Zaharin Ahmad
Abu Zaharin Ahmad

12 June 2023 in Energy
Verified
Journal Article
Closed access
Mohd Herwan SulaimanMohd Herwan Sulaiman
Mohd Herwan Sulaiman
ZMZuriani Mustaffa
Zuriani Mustaffa
NZNor Farizan Zakaria
Nor Farizan Zakaria
MSMohd Mawardi Saari
Mohd Mawardi Saari

27 October 2021 in IEEE Access
Verified
Journal Article
Open access
MZMohd Aufa Hadi Putera Zaini
Mohd Aufa Hadi Putera Zaini
MSMohd Mawardi Saari
Mohd Mawardi Saari
NNNurul A'IN Nadzri
Nurul A'IN Nadzri
ZAZulkifly Aziz
Zulkifly Aziz
NRNur Huda Ramlan
Nur Huda Ramlan
KTKeiji Tsukada
Keiji Tsukada
Magnetic Flux Leakage (MFL) and Eddy Current Testing (ECT) are commonly employed as the non-destructive evaluation (NDE) techniques used to detect defects within the steel. The MFL technique is advantageous in terms of deep defects detection, while the ECT technique excels in providing dense information regarding defects. In this work, artificial MFL and eddy current (EC) signals in ferromagnetic materials are studied, and an experimental magnetic probe that utilizes both techniques is developed for signal verification. The separation between MFL and EC signals is achieved by utilizing the phase-sensitive detection technique, implementing a dynamic referencing method as opposed to the conventional static phase referencing. A finite element method (FEM) based simulation is employed to study and verify the MFL and EC signals measured by the proposed magnetic probe. The proposed magnetic probe features highly sensitive anisotropic magneto-resistive sensors capable of measuring the MFL and EC signals induced by artificial slits of varying depths engraved onto a 2-mm carbon steel plate. Finite element simulations indicate different flux leakage patterns and eddy current signals detected in the vicinity of the back-side slits. A good agreement is observed between the simulated and the measured MFL and EC signals for the optimized frequency range of 110-210 Hz with the corresponding Lissajous curve for the detection of submillimeter back-side slits. The study has shown that the combination of MFL and EC signals can be successfully captured by an appropriate magnetic probe for an enhanced detection performance of back-side defects in ferromagnetic materials.

30 March 2025 in Energy
Verified
Journal Article
Closed access
Mohd Herwan SulaimanMohd Herwan Sulaiman
Mohd Herwan Sulaiman
ZMZuriani Mustaffa
Zuriani Mustaffa
MJMohd Shawal Jadin
Mohd Shawal Jadin
MSMohd Mawardi Saari
Mohd Mawardi Saari

3 May 2021 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
MSMohd Mawardi Saari
Mohd Mawardi Saari
NNNurul Ain Nadzri
Nurul Ain Nadzri
MZMohd Aufa Hadi Putera Zaini
Mohd Aufa Hadi Putera Zaini
NRNur Huda Ramlan
Nur Huda Ramlan
KTKeiji Tsukada
Keiji Tsukada
Detecting defects in high-permeability steel components can be challenging when using the eddy current technique. This is due to the strong magnetization signal that is simultaneously generated along with the eddy current signal. To minimize the regions of the induced eddy current and its detection, an eddy current probe based on an array of miniature fluxgate sensors (DRV425; Texas Instrument, USA) and axial inductors was proposed and fabricated in the study. The fluxgate sensors were arranged in two layers, and the sensors were sandwiched between two layers of inductors. The output signals from the fluxgate array were sampled to obtain a differential signal of the eddy current intensity and direction. A phase-sensitive detection technique was implemented to isolate the strong magnetization signal from the detected eddy current signal and utilized to characterize artificial slits with varying depths. The developed probe successfully characterized both the vertically and horizontally oriented slits with depths from 2 to 10 mm on a 12 mm-thick mild steel plate. A better sensitivity was notable in the evaluation of the vertical slits where the vertical slits would increase the eddy current intensity in contrast to the horizontal slits around the slits. It was shown that the eddy current’s distribution map obtained from the developed probe could be used to reveal the physical dimension of the slit.

18 February 2016 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
KTKeiji Tsukada
Keiji Tsukada
Koji MoritaKoji Morita
Koji Morita
YMYasuaki Matsunaga
Yasuaki Matsunaga
MSMohd Mawardi Saari
Mohd Mawardi Saari
KSKenji Sakai
Kenji Sakai
Toshihiko KiwaToshihiko Kiwa
Toshihiko Kiwa
Highly sensitive measurement of the very weak magnetic characteristics of magnetic particles in solution or of a solution itself is required for applications, such as biomedical examinations. In this paper, higher sensitivity and additional performance with relaxation measurement and harmonic signal detection were achieved by an improvement of the driving mechanism and the high-resolution electric magnet, and optimization of the superconducting quantum interference device (SQUID) detection unit. A servomotor was used for sample vibration and rotation with precise control and high speed. For detection of the M-H characteristics, the sample was vibrated under the magnetic field in the electromagnet. For measuring the relaxation of the magnetization, the sample was rotated. A first-order differential pickup coil with a normal conducting wire connected to the input coil of a high-temperature superconductor-SQUID was used to detect the magnetic signal from the sample. High-resolution measurement of the magnetic moment on the order of 10-11 A m2 was achieved with this system configuration. An ac magnetic field with a dc bias could then be applied to the sample for detection of the harmonic signal. The magnetic relaxation signal from the sample was measured by another of the same type of differential detection coil equipped outside of the electric magnet by rotating, instead of vibrating, the sample. The magnetization curve for a low concentration of iron nanoparticles with a superparamagnetic character in the solution was successfully measured using the developed magnetometer, and the relaxation phenomenon was also characterized.