Mehdi Öztürk

Dr. Mehdi Öztürk

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2022 in Buildings
Verified
Journal Article
Open access
PDF file
MÖMehdi Öztürk
Mehdi Öztürk
GAGuray Arslan
Guray Arslan
Active research is ongoing regarding the mechanical behavior of structural members manufactured from geopolymer concrete (GC), as it lacks standardized/codified manufacturing and design procedures. This study aims to address the shear behavior of GC beams. First, a consistent trial–error-based approach was used to develop the optimal mixture ratio (102.38/234.0 for NaOH/Na2SiO3) in terms of workability and consistency for the production of six (6) test specimens with span-to-depth ratios of (a/d) of 2.5, 3.5, and 4.5 and transverse reinforcement intervals of 10, 15, and 20 cm. Then, shear failure tests using a three-point bending setup were conducted and analyzed statistically. As a first attempt in the literature, an empirical expression for shear capacity prediction that was specifically tuned for GC beams was given. This expression, along with seven other similar expressions for ordinary concrete beams from the literature, and various practice codes were tested against a pool of experimental shear failure results given by four (4) different researchers. As a measure of the predictive capability, coefficient of variation (COV = standard deviation/average) values were obtained, and the lowest COV value of 0.305 suggested that the expression obtained the highest predictive capability, whereas more common practice codes such as ACI318, EN1992, and ENV1992 produced COV values of 0.435, 0.374, and 0.627, respectively. Finally, this study provides a working expression for the shear capacity estimation of GC beams and a mixture ratio for the practical manufacturing conditions of workability and consistency, with a slump value of 270 mm and a 90 min setting time.

17 September 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MÖMehdi Öztürk
Mehdi Öztürk
MKMehmet Ali KARAN
Mehmet Ali KARAN
This study investigates the seismic performance of existing reinforced concrete (RC) buildings, focusing on the influence of near-fault ground motions caused by proximity to fault lines. Compared to ordinary or far-fault earthquakes, near-fault earthquakes may have diverse effects on the response of buildings resulting from directivity and intense velocity pulses, which significantly amplify seismic demands. For this purpose, nonlinear time history analyses were carried out on a seven-story RC residential building that was subjected to near-fault effects and sustained heavy damage during the Kahramanmaraş earthquakes on 6 February 2023. The analyses used both near-fault and far-fault ground motion records, and four structural models were developed by gradually reducing the number of shear wall elements to assess the impact of diminishing lateral-load-resisting capacity. The results revealed that near-fault ground motions led to significant increases in base shear, inter-story drift ratios, and structural damage levels. Furthermore, a reduction in shear wall content resulted in a noticeable decline in seismic performance. These findings underscore the necessity of accounting for near-fault effects in seismic design and the critical role of lateral stiffness. The study emphasizes that considering near-fault characteristics is essential for ensuring the seismic resilience of RC buildings located in active seismic zones.

5 January 2023 in Buildings
Verified
Journal Article
Open access
PDF file
MÖMehdi Öztürk
Mehdi Öztürk
GAGuray Arslan
Guray Arslan
Geopolymer concrete (GC) is an emerging alternative construction material due to it being eco-friendly in production with considerably low carbon emissions. Despite being an alternative material, the structural behavior of GC is a rarely studied subject in the literature. The studies concerning the mechanical behavior of structural members made from GC have established the foundations of its practical usability. The current structural codes are exclusively for ordinary Portland cement concrete (OPCC), and the utilization of these for GC constitutes an open question. In this study, 12 GC beams with different shear span-to-effective depth ratios of 2.5, 3.5 and 4.5 were manufactured and tested in a three-point bending test setup. The effect of the shear reinforcement ratio was also taken into account (0, 0.34, 0.45 and 0.67%). The results were compared with the predictive capabilities of four structural codes and two equations in the literature (all for OPCC). In addition, comparisons were made with a very limited number of studies, which included predictive tools for the strength of GC. All specimens’ cracking moments were calculated with flexural tensile strength predictions and compared with experimental cracking moments. Moreover, particularly for the beams that failed in flexure, the ultimate bending moments were compared with the predictions of two structural codes for OPCC. It was observed that the best predictions of the cracking moment could be made by the equation of Diaz-Loya et al. (2011), which resulted in the lowest coefficient of variation (COV) and consistently predicted on the safe side, whereas, even with a lower COV, EC2 consistently overestimated the cracking moment. For the ultimate moment capacity, it was observed that both ACI318 (2019) and TS500 (2000) delivered relatively good predictions and could be employed confidently.

22 June 2025 in Buildings
Verified
Journal Article
Open access
PDF file
CMCagri Mollamahmutoglu
Cagri Mollamahmutoglu
MÖMehdi Öztürk
Mehdi Öztürk
MYMehmet Ozan Yılmaz
Mehmet Ozan Yılmaz
This study investigates the in-plane shear behavior of solid brick masonry walls, both unreinforced and retrofitted using Reinforced Khorasan Jacketing (RHJ), a traditional pozzolanic mortar technique rooted in Iranian and Ottoman architecture. Six one-block-thick English bond masonry walls were tested in three configurations: unreinforced with Horasan plaster (Group I), reinforced with steel mesh aligned to wall edges (Group II), and reinforced with mesh aligned diagonally (Group III). All the walls were plastered with 3.5 cm of Horasan mortar and tested after 18 months using diagonal compression, with load-displacement data recorded. A detailed 3D micro-modeling approach was employed in finite element simulations, with bricks and mortar modeled separately. The Horasan mortar was represented using an elastoplastic Mohr-Coulomb model with a custom softening law (parabolic-to-exponential), calibrated via inverse parameter fitting using the Nelder-Mead algorithm. The numerical predictions closely matched the experimental data. Reinforcement improved the shear strength significantly: Group II showed a 1.8 times increase, and Group III up to 2.7 times. Ductility, measured as post-peak deformation capacity, increased by factors of two (parallel) and three (diagonal). These enhancements transformed the brittle failure mode into a more ductile, energy-absorbing behavior. RHJ is shown to be a compatible, effective retrofit solution for historic masonry structures.

1 June 2025 in Gazi University Journal of Science
Verified
Journal Article
Open access
PDF file
GAGüray Arslan
Güray Arslan
MÖMehdi Öztürk
Mehdi Öztürk
KSKadir Sengun
Kadir Sengun
In this study, beams produced by geopolymer concrete (GC) with different properties such as compressive strengths, stirrups ratios, and shear-span to effective depth ratio (a/d) were tested up to the failure to attain the load-deflection behaviors. Then, tested damaged beams were retrofitted using Carbon Fiber Reinforced Polymer (CFRP) in both shear and flexure to examine the CFRP strengthening efficiency. A three-point flexural test was conducted on both reference and retrofitted GC beams. According to this study, applying the CFRP strengthening to damaged GC beams increased the load-carrying capacity between 4% - 72%, depending on the compressive strength, stirrups spacing, and a/d with reference to the reference GC beams. The area calculated under the load-deflection graph of the retrofitted GC beams was lower than the reference beams in all tested series. The initial stiffness in the tested retrofitted beams was generally obtained lower compared to the reference GC beams. The deflection capability of the retrofitted beams in the tested series was between 18% -80% lower than the reference beams.

19 December 2025 in Bulletin of Earthquake Engineering
Verified
Journal Article
Closed access
PDF file
CMCagri Mollamahmutoglu
Cagri Mollamahmutoglu
MÖMehdi Öztürk
Mehdi Öztürk
Ceyhun AksoyluCeyhun Aksoylu
Ceyhun Aksoylu
EMEmrah Madenci
Emrah Madenci
Yasin OzkilicYasin Ozkilic
Yasin Ozkilic