Che-Wei Hu

Che-Wei Hu

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
ABArnold Baca
Arnold Baca
Peter DabnichkiPeter Dabnichki
Peter Dabnichki
CHChe-Wei Hu
Che-Wei Hu
PKPhilipp Kornfeind
Philipp Kornfeind
Juliana ExelJuliana Exel
Juliana Exel
The use of small, interconnected and intelligent tools within the broad framework of pervasive computing for analysis and assessments in sport and physical activity is not a trend in itself but defines a way for information to be handled, processed and utilised: everywhere, at any time. The demand for objective data to support decision making prompted the adoption of wearables that evolve to fulfil the aims of assessing athletes and practitioners as closely as possible with their performance environments. In the present paper, we mention and discuss the advancements in ubiquitous computing in sports and physical activity in the past 5 years. Thus, recent developments in wearable sensors, cloud computing and artificial intelligence tools have been the pillars for a major change in the ways sport-related analyses are performed. The focus of our analysis is wearable technology, computer vision solutions for markerless tracking and their major contribution to the process of acquiring more representative data from uninhibited actions in realistic ecological conditions. We selected relevant literature on the applications of such approaches in various areas of sports and physical activity while outlining some limitations of the present-day data acquisition and data processing practices and the resulting sensors’ functionalities, as well as the limitations to the data-driven informed decision making in the current technological and scientific framework. Finally, we hypothesise that a continuous merger of measurement, processing and analysis will lead to the development of more reliable models utilising the advantages of open computing and unrestricted data access and allow for the development of personalised-medicine-type approaches to sport training and performance.

6 July 2022 in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
Verified
Journal Article
Closed access
CHChe-Wei Hu
Che-Wei Hu
CNCanh Toan Nguyen
Canh Toan Nguyen
Dominik Peter HoelblingDominik Peter Hoelbling
Dominik Peter Hoelbling
TPToh Yen Pang
Toh Yen Pang
ABArnold Baca
Arnold Baca
PDPeter Dabnichki
Peter Dabnichki
Conventional corrective insoles for flatfoot individuals traditionally utilise solid arch support to prevent the collapse of medial longitudinal arch. Such design restricts the foot arch compression and recoil in stance phase and increases the expanded energy during gait. In this study, a novel customised design insole was designed and manufactured using person's 3D foot scans. A novel elastic mesh pad was implemented in the mid-insole to replace the conventional solid arch support. The new insoles were tested in standard straight gait laboratory trials. The kinematic analysis showed that the novel insoles improved foot arch compression and recoil in stance phase with flatfooted individuals. Finally, the new insoles were provided to the participants to be habitually worn during a prolonged period of daily usage. The obtained gait analysis results and user feedback indicate strongly that the novel insoles provide improved comfort, static and dynamic balance, and arch support in stance phase. In summary, the new insoles show substantive potential in addressing the shortcomings of the widely used passive support ones while providing less restrictive and effective dynamic support.

9 July 2021 in Medical Engineering & Physics
Verified
Journal Article
Closed access
CHChe-Wei Hu
Che-Wei Hu
Peter DabnichkiPeter Dabnichki
Peter Dabnichki
ABArnold Baca
Arnold Baca
CNCanh Toan Nguyen
Canh Toan Nguyen
Toh Yen PangToh Yen Pang
Toh Yen Pang
A non-invasive, no radiation, out-of-hospital automated system is proposed to identify low arch integrated in the design and manufacturing of personalized orthoses using parametric modelling. The aim of the design process is to integrate assistive technology with assessment and prevent low arch progressing to a more serious case - flatfoot. In the automated procedure, we developed an assessment method including reliable thresholds of foot type classification and test protocol to reduce interferences due to preceding activities, an automation to translate scanned data into parametric design for orthotic customization, finite element model evaluating effectiveness of the personalized design, and a personalized comparative test to evaluate the long-term improvement of foot arch shape. Our low arch threshold established by subject-specific 3D models reduced the misclassification rate from 55%, as previously reported to 6.9%. Individuals who engaged in sedentary activity (i.e. sitting) had the greater change in arch height compared to active activity (i.e. standing and walking), which is more likely to affect the obtained measure. Therefore, a test protocol now states that participants are not allowed to sit over 100 min prior the measurement to reduce such interference. We have proposed and tested an automated algorithm to translate scanned data including seven foot's parameters into customised parametric design of the insert. The method decreases the required time of orthotic computer-aided design from over 3 h to less than 2 min. A finite element analysis procedure was additionally developed to assess the performance of geometries and material of designed orthotic based on the distribution of plantar pressure and internal stress. The personalized comparative assessment based on midfoot contact area was carried out periodically for follow-up and the orthotic could be re-designed if necessary. The proposed automated procedure develops a pre-screening system to distinguish low arch and provide preventatives before it becomes symptomatic. Furthermore, non-symptom flatfoot can be detected at early stages and referred to medics for further diagnosis or treatment.