Methane, a major contributor to climate change, is emitted by a variety of natural and anthropogenic sources. Commercially available lab-grade instruments for sensing trace methane are expensive, and previous efforts to develop inexpensive, field-deployable trace methane sensors have had mixed results. Industrial and commercial metal oxide (MOx) methane sensors, which are intended for leak detection and safety monitoring, can potentially be repurposed and adapted for low-concentration sensing. As an initial step towards developing a low-cost sensing system, we characterize the performance of five off-the-shelf MOx sensors for 2–10 ppm methane detection in a laboratory setting (Figaro Engineering TGS2600, TGS2602, TGS2611-C00, TGS2611-E00, and Henan Hanwei Electronics MQ4). We identify TGS2611-C00, TGS2611-E00, and MQ4 as promising for trace methane sensing but show that variations in ambient humidity and temperature pose a challenge for the sensors in this application.
Rationale To investigate whether the mutational landscape of circulating cell-free DNA (cfDNA) could predict and dynamically monitor the response to first-line platinum-based chemotherapy in patients with advanced non-small-cell lung cancer (NSCLC).
Indoor air quality is critical to human health, as individuals spend an average of 90% of their time indoors. However, indoor particulate matter (PM) sensor networks are not deployed as often as outdoor sensor networks. In this study, indoor PM2.5 exposure is investigated via 2 low-cost sensor networks in Pittsburgh. The concentrations reported by the networks were fed into a Monte Carlo simulation to predict daily PM2.5 exposure for 4 demographics (indoor workers, outdoor workers, schoolchildren, and retirees). Additionally, this study compares the effects of 4 different correction factors on reported concentrations from the PurpleAir sensors, including both empirical and physics-based corrections. The results of the Monte Carlo simulation show that mean PM2.5 exposure varied by 1.5 μg/m3 or less when indoor and outdoor concentrations were similar. When indoor PM concentrations were lower than outdoor, increasing the time spent outdoors on the simulation increased exposure by up to 3 μg/m3. These differences in exposure highlight the importance of carefully selecting sites for sensor deployment and show the value of having a robust low-cost sensor network with both indoor and outdoor sensor placement.
13 September 2024 in Science of The Total Environment
We developed a low-cost methane sensing node incorporating two metal oxide (MOx) sensors (Figaro Engineering TGS2611-E00 and TGS2600), humidity and temperature sensing, data storage, and telemetry. We deployed the prototype sensor alongside a reference methane analyzer at two sites: one outdoors and one indoors. We collected data at each site for several months across a range of environmental conditions (particularly temperature and humidity) and methane levels. We explored calibration models to investigate the performance of our system and its suitability for methane background monitoring and enhancement detection, first selecting a linear regression to fit a sensor baseline response and then fitting methane response by the sensor deviation from baseline. We achieved moderate accuracy in a 2 to 10 ppm methane range compared to data from the reference analyzer (RMSE < 0.6 ppm), but we found that the sensor response varied over time, possibly as a result of changes in non-targeted gas concentrations. We suggest that this cross sensitivity may be responsible for mixed results in previous studies. We discuss the implications of our results for the use of these and similar inexpensive MOx sensors for methane monitoring in the 2 to 10 ppm range.