Opitz Joerg

Dr. Opitz Joerg

Fraunhofer IKTS
+1
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2014 in Carbon
Verified
Journal Article
Closed access
KDKeivan Davami
Keivan Davami
MSMehrdad Shaygan
Mehrdad Shaygan
NKNazli Kheirabi
Nazli Kheirabi
JZJiong Zhao
Jiong Zhao
DKDaria A. Kovalenko
Daria A. Kovalenko
MMM. Meyyappan
M. Meyyappan

13 April 2020 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
Natalia BeshchasnaNatalia Beshchasna
Natalia Beshchasna
Muhammad SaqibMuhammad Saqib
Muhammad Saqib
HKHonorata Kraskiewicz
Honorata Kraskiewicz
ŁWŁukasz Wasyluk
Łukasz Wasyluk
OKOleg Kuzmin
Oleg Kuzmin
EAEcaterina Andronescu
Ecaterina Andronescu
Cardiovascular diseases are the most distributed cause of death worldwide. Stenting of arteries as a percutaneous transluminal angioplasty procedure became a promising minimally invasive therapy based on re-opening narrowed arteries by stent insertion. In order to improve and optimize this method, many research groups are focusing on designing new or improving existent stents. Since the beginning of the stent development in 1986, starting with bare-metal stents (BMS), these devices have been continuously enhanced by applying new materials, developing stent coatings based on inorganic and organic compounds including drugs, nanoparticles or biological components such as genes and cells, as well as adapting stent designs with different fabrication technologies. Drug eluting stents (DES) have been developed to overcome the main shortcomings of BMS or coated stents. Coatings are mainly applied to control biocompatibility, degradation rate, protein adsorption, and allow adequate endothelialization in order to ensure better clinical outcome of BMS, reducing restenosis and thrombosis. As coating materials (i) organic polymers: polyurethanes, poly(ε-caprolactone), styrene-b-isobutylene-b-styrene, polyhydroxybutyrates, poly(lactide-co-glycolide), and phosphoryl choline; (ii) biological components: vascular endothelial growth factor (VEGF) and anti-CD34 antibody and (iii) inorganic coatings: noble metals, wide class of oxides, nitrides, silicide and carbide, hydroxyapatite, diamond-like carbon, and others are used. DES were developed to reduce the tissue hyperplasia and in-stent restenosis utilizing antiproliferative substances like paclitaxel, limus (siro-, zotaro-, evero-, bio-, amphi-, tacro-limus), ABT-578, tyrphostin AGL-2043, genes, etc. The innovative solutions aim at overcoming the main limitations of the stent technology, such as in-stent restenosis and stent thrombosis, while maintaining the prime requirements on biocompatibility, biodegradability, and mechanical behavior. This paper provides an overview of the existing stent types, their functionality, materials, and manufacturing conditions demonstrating the still huge potential for the development of promising stent solutions.

23 September 2009 in Journal of Biophotonics
Verified
Journal Article
Closed access
PDF file
MMMsaukiranji Mkandawire
Msaukiranji Mkandawire
APAndrea Pohl
Andrea Pohl
TGTatiana Gubarevich
Tatiana Gubarevich
VLVictoria Lapina
Victoria Lapina
DADietmar Appelhans
Dietmar Appelhans
Opitz JoergOpitz Joerg
Opitz Joerg

28 July 2006 in Small
Verified
Journal Article
Closed access
PDF file
CDCerasela Zoica Dinu
Cerasela Zoica Dinu
Opitz JoergOpitz Joerg
Opitz Joerg
WPWolfgang Pompe
Wolfgang Pompe
JHJonathon Howard
Jonathon Howard
MMMichael Mertig
Michael Mertig
SDStefan Diez
Stefan Diez

10 May 2013 in Nano Research
Verified
Journal Article
Closed access
PDF file
SPSebastian Pregl
Sebastian Pregl
WWWalter M. Weber
Walter M. Weber
DNDaijiro Nozaki
Daijiro Nozaki
JKJens Kunstmann
Jens Kunstmann
Larysa BarabanLarysa Baraban
Larysa Baraban
Gianaurelio CunibertiGianaurelio Cuniberti
Gianaurelio Cuniberti
We present novel Schottky barrier field effect transistors consisting of a parallel array of bottom-up grown silicon nanowires that are able to deliver high current outputs. Axial silicidation of the nanowires is used to create defined Schottky junctions leading to on/off current ratios of up to 106. The device concept leverages the unique transport properties of nanoscale junctions to boost device performance for macroscopic applications. Using parallel arrays, on-currents of over 500 μA at a source-drain voltage of 0.5 V can be achieved. The transconductance is thus increased significantly while maintaining the transfer characteristics of single nanowire devices. By incorporating several hundred nanowires into the parallel array, the yield of functioning transistors is dramatically increased and deviceto-device variability is reduced compared to single devices. This new nanowirebased platform provides sufficient current output to be employed as a transducer for biosensors or a driving stage for organic light-emitting diodes (LEDs), while the bottom-up nature of the fabrication procedure means it can provide building blocks for novel printable electronic devices. Open image in new window

3 January 2014 in Nano Research
Verified
Journal Article
Closed access
PDF file
FZFelix M. Zörgiebel
Felix M. Zörgiebel
SPSebastian Pregl
Sebastian Pregl
LRLotta Römhildt
Lotta Römhildt
Opitz JoergOpitz Joerg
Opitz Joerg
WWW. Weber
W. Weber
Gianaurelio CunibertiGianaurelio Cuniberti
Gianaurelio Cuniberti
We demonstrate a pH sensor based on ultrasensitive nanosize Schottky junctions formed within bottom-up grown dopant-free arrays of assembled silicon nanowires. A new measurement concept relying on a continuous gate sweep is presented, which allows the straightforward determination of the point of maximum sensitivity of the device and allows sensing experiments to be performed in the optimum regime. Integration of devices into a portable fluidic system and an electrode isolation strategy affords a stable environment and enables long time robust FET sensing measurements in a liquid environment to be carried out. Investigations of the physical and chemical sensitivity of our devices at different pH values and a comparison with theoretical limits are also discussed. We believe that such a combination of nanofabrication and engineering advances make this Schottky barrier-powered silicon nanowire lab-on-a-chip platform suitable for efficient biodetection and even for more complex biochemical analysis.