Background: Neonatal screening programs for congenital adrenal hyperplasia (21-CAH) using an immunoassay for 17α-hydroxyprogesterone (17-OHP) generate a high rate of positive results attributable to physiological reasons and to cross-reactions with steroids other than 17α-OHP, especially in preterm neonates and in critically ill newborns. Methods: To increase the specificity of the screening process, we applied a liquid chromatography-tandem mass spectrometry method quantifying 17α-OHP, 11-deoxycortisol, 21-deoxycortisol, cortisol, and androstenedione. The steroids were eluted in aqueous solution containing d8-17α-OHP and d2-cortisol and quantified in multiple reaction mode. Results: Detection limit was below 1 nmol/liter, and recovery ranged from 64% (androstenedione) to 83% (cortisol). Linearity was proven within a range of 5–100 nmol/liter (cortisol, 12.5–200 nmol/liter), and total run time was 6 min. Retrospective analysis of 6151 blood samples and 50 blood samples from newborns with clinically confirmed 21-CAH, as well as prospective analysis of 1609 samples of a total of 242,500 testing positive in our routine 17-OHP immunoassay, allowed clear distinction of affected and nonaffected newborns. High levels of 21-deoxycortisol were only found in children with 21-hydroxylase deficiency. Calculating the ratio of 17α-OHP to 21-deoxycortisol divided by cortisol further increased the sensitivity of the method. Conclusion: Our liquid chromatography-tandem mass spectrometry procedure as a second-tier test can be used to reduce false-positive results of standard 21-CAH screening. The short total run time of 6 min allows for immediate reanalysis of all immunoassay results above the cutoff.
Newborn screening (NBS) programs for treatable metabolic disorders have been enormously successful, but molecular-based screening has not been broadly implemented so far. This prospective pilot study was performed within the German NBS framework. DNA, extracted from dried blood cards was collected as part of the regular NBS program. As cystinosis has a prevalence of only 1:100,000-1:200,000, a molecular genetic assay for detection of the SMN1 gene mutation with a higher prevalence was also included in the screening process, a genetic defect that leads to spinal muscular atrophy (SMA). First tier multiplex PCR was employed for both diseases. The cystinosis screening employed assays for the three most common CTNS mutations covering 75% of German patients; in case of heterozygosity for one of these mutations, samples were screened by next generation sequencing (NGS) of the CTNS exons for 101 CTNS mutations. A detection rate of 98.5% is predicted using this approach. Between January 15, 2018 and May 31, 2019, 257,734 newborns were screened in Germany for cystinosis. One neonate was diagnosed with cystinosis, consistent with the known incidence of the disease. No false positive or false negatives were detected so far. Screening, communication of findings to parents, and confirmation of diagnosis were accomplished in a multi-disciplinary setting. This program was accomplished with the cooperation of hospitals, physicians, and parents. In the neonate diagnosed with cystinosis, oral cysteamine treatment began on day 18. After 16 months of treatment the child has no clinical signs of renal tubular Fanconi syndrome. This pilot study demonstrates the efficacy of a molecular-based neonatal screening program for cystinosis using an existing national screening framework.