Reconstruction of irregular oral-maxillofacial bone defects with an inflammatory microenvironment remains a challenge, as chronic local inflammation can largely impair bone healing. Here, we used magnesium silicate nanospheres (MSNs) to load microRNA-146a-5p (miR-146a) to fabricate a nanobiomaterial, MSN+miR-146a, which showed synergistic promoting effects on the osteogenic differentiation of human dental pulp stem cells (hDPSCs). In addition, miR-146a exhibited an anti-inflammatory effect on mouse bone marrow-derived macrophages (BMMs) under lipopolysaccharide (LPS) stimulation by inhibiting the NF-κB pathway via targeting tumor necrosis factor receptor-associated factor 6 (TRAF6), and MSNs could simultaneously promote M2 polarization of BMMs. MiR-146a was also found to inhibit osteoclast formation. Finally, the dual osteogenic-promoting and immunoregulatory effects of MSN+miR-146a were further validated in a stimulated infected mouse mandibular bone defect model via delivery by a photocuring hydrogel. Collectively, the MSN+miR-146a complex revealed good potential in treating inflammatory irregular oral-maxillofacial bone defects.
(1) Objectives: This study evaluated the clinical outcomes of dental implants placed in previously failed sites and discussed the risk factors that mattered in reimplantation. (2) Methods: All the cases by one specific implantologist during his first five years of clinical practice were screened, with a focus on those who received reimplantation. The clinical outcomes were assessed, including the implant survival, peri-implant health, and patients’ satisfaction. (3) Results: 28 patients (31 implants) were recorded as failures from 847 patients (1269 implants), with a 2.4% overall failure rate at the implant level, of whom 19 patients (21 implants) received reimplantation treatment. After a mean follow-up of 33.7 ± 10.1 months (95% CI 29.1–38.3 months), 20 implants remained functional, but 1 implant revealed a secondary early failure, indicating a 95.2% overall survival rate. The mean probing depth (PD), modified sulcus bleeding index (mSBI), and marginal bone loss (MBL) of the surviving reinserted implants were 2.7 ± 0.6 mm (95% CI 2.5–3.0 mm), 0.7 ± 0.5 (95% CI 0.5–1.0), and 0.5 ± 0.6 mm (95% CI 0.3–0.8 mm), respectively. Embedded healing occurred more frequently in the reinserted implants than in the primary implants (p = 0.052). The patients’ satisfaction suffered from implant failure, but a successful reimplantation could reverse it with close doctor–patient communication. (4) Conclusions: Reimplantation treatment was recommended, based on a thorough evaluation and consideration of the risk factors combined with effective communication with the patients.
10 October 2023 in Clinical Oral Implants Research
This retrospective study was intended to evaluate the clinical accuracy of partially guided template in guiding implant placement in edentulous patients. A total of 120 implants were placed in 24 patients with at least one completely edentulous arch with a partially guided system. Based on CBCT data, a repeatable method was used to measure linear and angular deviations of implants at 3D level in Mimics medical software. The influence of supporting tissue and implant region on the accuracy was assessed, followed by the evaluation of direction of linear deviations in biologically vital areas. Linear deviations of all implants were 1.91 ± 0.68 mm, 1.47 ± 0.68 mm, and 1.02 ± 0.69 mm at apical, apical lateral, and apical vertical levels. When at the cervical, cervical lateral, and cervical vertical levels, the linear deviations were 1.53 ± 0.65 mm, 0.98 ± 0.53 mm, and 1.01 ± 0.69 mm, respectively. Angular deviation of all implants was 7.14 ± 3.41°. Implants guided by mucosa + tooth-supported templates showed higher linear deviations at apical vertical level (1.21 ± 0.72 mm vs. 0.86 ± 0.63 mm, p < .05) and cervical vertical level (1.18 ± 0.72 mm vs. 0.87 ± 0.63 mm, p < .05) than mucosa-supported templates, and implants in maxilla were found higher angular deviation than mandible (7.89 ± 3.61° vs. 6.29 ± 2.97°, p < .05). The partially guided template served as clinically viable surgical assistance in implant placement in edentulous patients. When using mucosa + tooth-supported template or placing implants in maxilla, more caution was required, especially in biologically vital areas.
21 April 2026 in Clinical Implant Dentistry and Related Research