Ludvik Alkhoury

Mr. Ludvik Alkhoury

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JCJi-Won Choi
Ji-Won Choi
Ludvik AlkhouryLudvik Alkhoury
Ludvik Alkhoury
LULeonardo F. Urbano
Leonardo F. Urbano
PMPuneet Masson
Puneet Masson
MVMatthew VerMilyea
Matthew VerMilyea
MKMoshe Kam
Moshe Kam
Computer-Assisted Semen Analysis (CASA) enables reliable analysis of semen images, and is designed to process large number of images with high consistency, accuracy, and repeatability. Design and testing of CASA algorithms can be accelerated greatly if reliable simulations of semen images under a variety of conditions and sample quality modes are available. Using life-like simulation of semen images can quantify the performance of existing and proposed CASA algorithms, since the parameters of the simulated image are known and controllable. We present simulation models for sperm cell image and swimming modes observed in real 2D (top-down) images of sperm cells in laboratory specimen. The models simulate human sperm using four (4) types of swimming, namely linear mean, circular, hyperactive, and immotile (or dead). The simulation models are used in studying algorithms for segmentation, localization, and tracking of sperm cells. Several segmentation and localization algorithms were tested under varying levels of noise, and then compared using precision, recall, and the optimal subpattern assignment (OSPA) metric. Images of real human semen sample were used to validate the segmentation and localization observations obtained from simulations. An example is given of sperm cell tracking on simulated semen images of cells using the different tracking algorithms (nearest neighbor (NN), global nearest neighbor (GNN), probabilistic data association filter (PDAF), and joint probabilistic data association filter (JPDAF)). Tracking performance was evaluated through multi-object tracking precision (MOTP) and multi-object tracking accuracy (MOTA). Simulation models enable objective assessments of semen image processing algorithms. We demonstrate the use of a new simulation tool to assess and compare segmentation, localization, and tracking methods. The simulation software allows testing along a large spectrum of parameter values that control the appearance and behavior of simulated semen images. Users can generate scenarios of different characteristics and assess the effectiveness of different CASA algorithms in these environments. The simulation was used to assess and compare algorithms for segmentation and tracking of sperm cells in semen images.

17 June 2020 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Open access
PDF file
Ludvik AlkhouryLudvik Alkhoury
Ludvik Alkhoury
JCJi-Won Choi
Ji-Won Choi
CWChizhong Wang
Chizhong Wang
ARArjun Rajasekar
Arjun Rajasekar
SASayandeep Acharya
Sayandeep Acharya
MKMoshe Kam
Moshe Kam
Calculation of peripheral capillary oxygen saturation $${\text{(SpO}}_{{\text{2}}} {\text{)}}$$ (SpO 2 ) levels in humans is often made with a pulse oximeter, using photoplethysmography (PPG) waveforms. However, measurements of PPG waveforms are susceptible to motion noise due to subject and sensor movements. In this study, we compare two $${\text{SpO}}_{{\text{2}}}$$ SpO 2 -level calculation techniques, and measure the effect of pre-filtering by a heart-rate tuned comb peak filter on their performance. These techniques are: (1) “Red over Infrared,” calculating the ratios of AC and DC components of the red and infrared PPG signals, $$\frac{(AC/DC)_{red}}{(AC/DC)_{infrared}}$$ ( A C / D C ) red ( A C / D C ) infrared , followed by the use of a calibration curve to determine the $${\text{SpO}}_{{\text{2}}}$$ SpO 2 level Webster (in: Design of pulse oximeters, CRC Press, Boca Raton, 1997); and (2) a motion-resistant algorithm which uses the Discrete Saturation Transform (DST) (Goldman in J Clin Monit Comput 16:475–83, 2000). The DST algorithm isolates individual “saturation components” in the optical pathway, which allows separation of components corresponding to the $${\text{SpO}}_{{\text{2}}}$$ SpO 2 level from components corresponding to noise and interference, including motion artifacts. The comparison we provide here (employing the two techniques with and without pre-filtering) addresses two aspects: (1) accuracy of the $${\text{SpO}}_{{\text{2}}}$$ SpO 2 calculations; and (2) computational complexity. We used both synthetic data and experimental data collected from human subjects. The human subjects were tested at rest and while exercising; while exercising, their measurements were subject to the impacts of motion. Our main conclusion is that if an uninterrupted high-quality heart rate measurement is available, then the “Red over Infrared” approach preceded by a heart-rate tuned comb filter provides the preferred trade-off between $${\text{SpO}}_{{\text{2}}}$$ SpO 2 -level accuracy and computational complexity. A modest improvement in $${\text{SpO}}_{{\text{2}}}$$ SpO 2 estimate accuracy at very low SNR environments may be achieved by switching to the pre-filtered DST-based algorithm (up to 6% improvement in $${\text{SpO}}_{{\text{2}}}$$ SpO 2 level accuracy at −10 dB over unfiltered DST algorithm and the filtered “Red over Infrared” approach). However, this improvement comes at a significant computational cost.

1 June 2025 in Journal of Neural Engineering
Verified
Journal Article
Open access
Ludvik AlkhouryLudvik Alkhoury
Ludvik Alkhoury
GSG Scanavini
G Scanavini
SLS Louviot
S Louviot
ARA Radanovic
A Radanovic
SSS A Shah
S A Shah
NHN J Hill
N J Hill
Objective . We present a novel and lightweight method that removes ocular artifacts from electroencephalography (EEG) recordings while demanding minimal training data. Approach . A robust, cross-validated thresholding procedure automatically detects the times at which eye blinks occur, then a linear scalp projection is estimated by regressing a simplified time-locked reference signal against the multi-channel EEG. Main results . Performance was compared against four commonly-used and readily available blink removal methods: signal subspace projection and forward regression (Reg) from the MNE toolbox, EEGLab’s independent component analysis (ICA) combined with ICLabel for automated component identification, and Artifact Subspace Reconstruction (ASR) Python implementation compatible with MNE. On semi-synthetic blink-contaminated EEG data, our method exhibited better reconstruction of the ground truth than the two MNE native methods, and comparable (or better in some scenarios) performance to ASR algorithm and ICA+IClabel. We also examined a real EEG dataset from 16 human participants, where the ground truth was unknown. Our method affected contaminated channels in blink intervals more than the two MNE native methods and ASR, while having a smaller impact on non-blink intervals, uncontaminated channels, and higher-frequency amplitudes, than the two MNE methods; its performance was again similar to ICA+ICLabel. On a second real dataset from 42 human participants, we showed that ARMBR removed the unwanted blink artifacts while successfully preserving the desired event-related-potential signals. Significance . The proposed algorithm exhibited comparable, and in some scenarios better performance relative to readily-available implementations of other widely-used methods. Another feature of our method is its potential as method for online applications. Therefore, it stands to make valuable contributions towards the automation of neural-engineering technologies and their translation from laboratory to clinical and other real-world usage.

17 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Ludvik AlkhouryLudvik Alkhoury
Ludvik Alkhoury
JCJi-won Choi
Ji-won Choi
VCVishnu D. Chandran
Vishnu D. Chandran
GCGabriela B. De Carvalho
Gabriela B. De Carvalho
SPSaikat Pal
Saikat Pal
MKMoshe Kam
Moshe Kam
The quality of heart rate (HR) measurements extracted from human photoplethysmography (PPG) signals are known to deteriorate under appreciable human motion. Auxiliary signals, such as accelerometer readings, are usually employed to detect and suppress motion artifacts. A 2019 study by Yifan Zhang and his coinvestigatorsused the noise components extracted from an infrared PPG signal to denoise a green PPG signal from which HR was extracted. Until now, this approach was only tested on “micro-motion” such as finger tapping. In this study, we extend this technique to allow accurate calculation of HR under high-intensity full-body repetitive “macro-motion”. Our Dual Wavelength (DWL) framework was tested on PPG data collected from 14 human participants while running on a treadmill. The DWL method showed the following attributes: (1) it performed well under high-intensity full-body repetitive “macro-motion”, exhibiting high accuracy in the presence of motion artifacts (as compared to the leading accelerometer-dependent HR calculation techniques TROIKA and JOSS); (2) it used only PPG signals; auxiliary signals such as accelerometer signals were not needed; and (3) it was computationally efficient, hence implementable in wearable devices. DWL yielded a Mean Absolute Error (MAE) of 1.22|0.57 BPM, Mean Absolute Error Percentage (MAEP) of 0.95|0.38%, and performance index (PI) (which is the frequency, in percent, of obtaining an HR estimate that is within ±5 BPM of the HR ground truth) of 95.88|4.9%. Moreover, DWL yielded a short computation period of 3.0|0.3 s to process a 360-second-long run.

24 December 2024 in HardwareX
Verified
Journal Article
Open access
Ludvik AlkhouryLudvik Alkhoury
Ludvik Alkhoury
GSGiacomo Scanavini
Giacomo Scanavini
PSPetras Swissler
Petras Swissler
SSSudhin A. Shah
Sudhin A. Shah
DGDisha Gupta
Disha Gupta
NHN. Jeremy Hill
N. Jeremy Hill
In neuroscience, accurately correlating brain activity with stimuli and other events requires precise synchronization between neural data and event timing. To achieve this, purpose-built synchronization devices are often used to detect events. This paper introduces SyncGenie, a programmable synchronization device designed for a range of uses in neuroscience research—primarily as a “trigger box” to align neurophysiological data with physical stimulus events, among other possibilities. It can support both hardware-triggered and software-triggered pulse synchronization and can even serve as a cost-effective digitizer for real-time analysis of analog signals. We provide the complete circuit-board designs, 3D models, and Arduino code necessary to build and use SyncGenie. The board is designed for easy manufacturing and assembly, with components that can be seamlessly soldered. It includes a range of connector types required for common applications, such as 3.5 mm TRS, D-sub25, BNC, and JST-XH. Additionally, SyncGenie features a user-friendly interface that allows for experiment-specific adjustments without requiring coding expertise. Its programmability, supported by our public-domain Arduino library, provides the flexibility to adapt SyncGenie to diverse experimental protocols. Overall, SyncGenie offers enhanced functionality at a lower cost relative to commercially available trigger boxes.

12 May 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
Ludvik AlkhouryLudvik Alkhoury
Ludvik Alkhoury
TMTony Moore
Tony Moore
PSPetras Swissler
Petras Swissler
JHJeremy Hill
Jeremy Hill
SSSudhin A. Shah
Sudhin A. Shah
MKMoshe Kam
Moshe Kam
Microcontrollers have become central to wearable technologies. As these systems continue to evolve, both form factor and functional integration have become critical design considerations. In this study, we present TinZr, a compact, wireless, and open-source controller based on the ESP32-C3 microcontroller. The TinZr integrates an inertial measurement unit (IMU), an onboard battery management circuit, Wi-Fi and Bluetooth Low Energy, a microSD card reader, and multiple GPIOs supporting digital, analog, I2C, SPI, and UART interfaces. The complete system measures only 25 mm × 25 mm, making it well-suited for wearable applications. All production files, including PCB design, firmware, and a 3D model of a wearable enclosure, are publicly available. Two primary use cases for TinZr are demonstrated: (a) multi-device communication and coordination, and (b) wireless IMU data acquisition. The TinZr supports both real-time data streaming via Wi-Fi/BLE and local logging to a microSD card. Local streaming makes the TinZr suitable for extended research experiments and field studies where continuous wireless connectivity may not be available. An accompanying Arduino library, TinZrConnect, is provided to facilitate programming and integration with existing systems. Overall, the combination of compact design, wireless flexibility, and open-source accessibility, makes TinZr a versatile solution for various sensing applications.