The presence of blood–brain barrier (BBB) and/or blood–brain–tumor barriers (BBTB) is one of the main obstacles to effectively deliver therapeutics to our central nervous system (CNS); hence, the outcomes following treatment of malignant brain tumors remain unsatisfactory. Although some approaches regarding BBB disruption or drug modifications have been explored, none of them reach the criteria of success. Convention-enhanced delivery (CED) directly infuses drugs to the brain tumor and surrounding tumor infiltrating area over a long period of time using special catheters. Focused ultrasound (FUS) now provides a non-invasive method to achieve this goal via combining with systemically circulating microbubbles to locally enhance the vascular permeability. In this review, different approaches of delivering therapeutic agents to the brain tumors will be discussed as well as the characterization of BBB and BBTB. We also highlight the mechanism of FUS-induced BBB modulation and the current progress of this technology in both pre-clinical and clinical studies.
Magnetic resonance-guided focused ultrasound (MRgFUS), in conjunction with circulating microbubbles, is an emerging technology that can transiently enhance the permeability of the blood-brain barrier (BBB) locally and non-invasively to facilitate targeted drug delivery to the brain. In this clinical trial, the feasibility and safety of BBB modulation in the putamen were evaluated for biweekly therapeutic agent delivery in patients with Parkinson’s disease. The performance of the clinical MRgFUS system’s cavitation feedback controller for active power modulation throughout the exposures was examined. The putamen was targeted unilaterally by an ExAblate Neuro MRgFUS system operating at 220 kHz. Definity microbubbles were infused via a saline bag gravity drip at a rate of 4 µL/kg per 5 min. A cavitation emissions-based feedback controller was employed to modulate the acoustic power automatically according to prescribed target cavitation dose levels. BBB opening was measured by Gadolinium (Gd)-enhanced T1-weighted MR imaging, and the presence of potential micro-hemorrhages induced by the exposures was assessed via T2*-weighted MR imaging. A total of 12 treatment sessions were carried out across four patients, with target cavitation dose levels ranging from 0.20–0.40. BBB permeability in the targeted putamen was elevated successfully in all treatments, with a 14% ± 6% mean increase in Gd-enhanced T1-weighted MRI signal intensity relative to the untreated contralateral side. No indications of red blood cell extravasations were observed on MR imaging scans acquired one day following each treatment session. The cavitation emissions-based feedback controller was effective in modulating acoustic power levels to ensure BBB permeability enhancement while avoiding micro-hemorrhages, however, further technical advancements are warranted to improve its performance for use across a wide variety of brain diseases.
This review discusses the current progress in the clinical use of magnetic resonance-guided focused ultrasound (MRgFUS) and other ultrasound platforms to transiently permeabilize the blood-brain barrier (BBB) for drug delivery in neurological disorders and neuro-oncology. Safety trials in humans have followed on from extensive pre-clinical studies, demonstrating a reassuring safety profile and paving the way for numerous translational clinical trials in Alzheimer’s disease, Parkinson’s disease, and primary and metastatic brain tumors. Future directions include improving ultrasound delivery devices, exploring alternative delivery approaches such as nanodroplets, and expanding the application to other neurological conditions.
29 August 2023 in IEEE Transactions on Biomedical Engineering
Recently, MRI-guided focused ultrasound (FUS) has shown great promise in treating various conditions non-invasively. Objective: The focus of this article is to introduce an MRI-guided FUS device, which can provide full electronic steering range without mechanical movement and with low near-field heating. A pilot study was conducted in order to investigate the feasibility, and safety of the device in a large animal model and a pilot clinical trial. Methods: A flat, fully steerable FUS phased array with 4096 elements was designed and manufactured to be compatible with an MR scanner. Pre-clinical experiments were carried out for testing the accuracy of the focus at different steering angles as well as evaluating the ablation efficiency using MR thermometry. Eleven patients with uterine fibroids were treated in the pilot clinical trial. Results: P re-clinical results showed successful ablation at various steering angles with reasonable targeting accuracy and no off-target heating. During the pilot clinical study, effective fibroid ablation was achieved with significant symptom reduction observed over time. In general, the treatment results showed the system to be effective in ablating deep tissue volumes. The device was successful at efficiently ablating large volumes with minimal near-field heating and eliminating the need for mechanical translation. Conclusions: Being capable of providing high acoustic power, full electronic steering range in 3D for large volume ablations, this device can provide a safe and efficient treatment option as an outpatient procedure for uterine fibroids and other pelvic and abdominal tumors.
2 December 2025 in IEEE Reviews in Biomedical Engineering
Focused ultrasound combined with intravenously infused microbubbles has been shown to effectively enhance the permeability of the blood-brain barrier, facilitating drug delivery to the brain. A wide range of technical parameters has been evaluated through preclinical studies and clinical trials. Generally, a low frequency between 200 and 300 kHz is preferred for the transcranial approach, while 1 MHz is used in implantable devices. Standard parameters include a burst length of 5 to 10 ms, a pulse repetition frequency of 0.2 to 10 Hz, and sonication durations of 90 to 180 seconds. A pressure magnitude around 0.46 mechanical index appears to be near the threshold for BBB permeability enhancement at standard microbubble dosage without causing hemorrhage. Various microbubble and nanobubble types have been tested at different doses, which in principle can be normalized by gas volume. Control methods that use harmonic emmisions for power feedback have been proposed to enhance consistency and account for patient variability, and these methods are currently being tested in several clinical trials.