22 April 2020 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
LVLiesbeth Vancoillie
Liesbeth Vancoillie
NMNicholas W. Marshall
Nicholas W. Marshall
LCLesley Cockmartin
Lesley Cockmartin
JVJanne Vignero
Janne Vignero
GZGuozhi Zhang
Guozhi Zhang
HBHilde Bosmans
Hilde Bosmans
<!-- *** Custom HTML *** --> Purpose: The impact of system parameters on signal detectability can be studied with simulation platforms. We describe the steps taken to verify and confirm the accuracy of a local platform developed for the use in virtual clinical trials. Approach: The platform simulates specific targets into existing two-dimensional full-field digital mammography and digital breast tomosynthesis images acquired on a Siemens Inspiration system. There are three steps: (1) creation of voxel models or analytical objects; (2) generation of a realistic object template with accurate resolution, scatter, and noise properties; and (3) insertion and reconstruction. Four objects were simulated: a 0.5-mm aluminium (Al) sphere and a 0.2-mm-thick Al sheet in a PMMA stack, a 0.8-mm steel edge and a three-dimensional mass model in a structured background phantom. Simulated results were compared to acquired data. Results: Peak contrast and signal difference-to-noise ratio (SDNR) were in close agreement (<5 % error) for both sphere and sheet. The similarity of pixel value profiles for sphere and sheet in the xy direction and the artifact spread function for real and simulated spheres confirmed accurate geometric modeling. Absolute and relative average deviation between modulation transfer function measured from a real and simulated edges showed accurate sharpness modelling for spatial frequencies up to the Nyquist frequency. Real and simulated objects could not be differentiated visually. Conclusions: The results indicate that this simulation framework is a strong candidate for use in virtual clinical studies.

12 January 2024 in European Journal of Radiology
Verified
Journal Article
Closed access
JLJiao Li
Jiao Li
JZJunying Zhu
Junying Zhu
YZYixuan Zou
Yixuan Zou
GZGuozhi Zhang
Guozhi Zhang
PZPan Zhu
Pan Zhu
PXPeiyi Xie
Peiyi Xie

11 March 2023 in European Radiology
Verified
Journal Article
Closed access
PDF file
RGRui Guo
Rui Guo
JDJiao Deng
Jiao Deng
PRPengfei Rong
Pengfei Rong
WZWanhui Zhou
Wanhui Zhou
GZGuozhi Zhang
Guozhi Zhang
PHPengzhi Hu
Pengzhi Hu

23 March 2019 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
DPDimitar Petrov
Dimitar Petrov
NMNicholas Marshall
Nicholas Marshall
KYKenneth Young
Kenneth Young
GZGuozhi Zhang
Guozhi Zhang
HBHilde Bosmans
Hilde Bosmans
We compare the reproducibility of the human observers and a channelized Hotelling observer (CHO), when reading digital breast tomosynthesis (DBT) images of a physical phantom containing a breast simulating structured background and calcification clusters at three dose levels. The phantom is scanned 217 times on a Siemens Inspiration DBT system. Volumes of interest, with and without the calcification targets, are extracted and the human observers’ percentage of correct (PC) scores is evaluated using a four-alternative forced choice method. A two-layer CHO is developed using the human observer results. The first layer consists of a localizing CHO that identifies the most conspicuous calcifications using two Laguerre–Gauss channels. Then a CHO with eight Gabor channels estimates the PC score for the calcification cluster. Observer reproducibility is estimated by bootstrapping, and the standard deviation (SD) is used as a figure of merit. The CHO closely approximated the human observer results for all the three dose levels with a correlation of >0.97. For the larger calcification cluster sizes, both observers have similar reproducibility, whereas the CHO is more reproducible for the smaller calcifications, with a maximum of 5.5 SD against 13.1 SD for the human observers. The developed CHO is a good candidate for automated reading of the calcification clusters of the structured phantom, with better reproducibility than the human readers for small calcifications.

3 October 2023 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
RGRui Guo
Rui Guo
YZYixuan Zou
Yixuan Zou
SZShuai Zhang
Shuai Zhang
JAJiajia An
Jiajia An
GZGuozhi Zhang
Guozhi Zhang
JMJing Ma
Jing Ma
Purpose: To validate a novel deep learning‐based metal artifact correction (MAC) algorithm for CT, namely, AI‐MAC, in preclinical setting with comparison to conventional MAC and virtual monochromatic imaging (VMI) technique.Materials and methods: An experimental phantom was designed by consecutively inserting two sets of pedicle screws (size Φ 6.5 × 30‐mm and Φ 7.5 × 40‐mm) into a vertebral specimen to simulate the clinical scenario of metal implantation. The resulting MAC, VMI, and AI‐MAC images were compared with respect to the metal‐free reference image by subjective scoring, as well as by CT attenuation, image noise, signal‐to‐noise ratio (SNR), contrast‐to‐noise ratio (CNR), and correction accuracy via adaptive segmentation of the paraspinal muscle and vertebral body.Results: The AI‐MAC and VMI images showed significantly higher subjective scores than the MAC image (all p < 0.05). The SNRs and CNRs on the AI‐MAC image were comparable to the reference (all p > 0.05), whereas those on the VMI were significantly lower (all p < 0.05). The paraspinal muscle segmented on the AI‐MAC image was 4.6% and 5.1% more complete to the VMI and MAC images for the Φ 6.5 × 30‐mm screws, and 5.0% and 5.1% for the Φ 7.5 × 40‐mm screws, respectively. The vertebral body segmented on the VMI was closest to the reference, with only 3.2% and 7.4% overestimation for Φ 6.5 × 30‐mm and Φ 7.5 × 40‐mm screws, respectively.Conclusions: Using metal‐free reference as the ground truth for comparison, the AI‐MAC outperforms VMI in characterizing soft tissue, while VMI is useful in skeletal depiction.

1 October 2017 in British Journal of Radiology
Verified
Journal Article
Closed access
SAStratis Andreas
Stratis Andreas
TNTouyz Nathan
Touyz Nathan
GZGuozhi Zhang
Guozhi Zhang
RJReinhilde Jacobs
Reinhilde Jacobs
BRBogaerts Ria
Bogaerts Ria
DPDimitra Project Partners
Dimitra Project Partners
Objective:To develop a database of paediatric head voxel models intended for Monte Carlo (MC) dosimetric applications.Methods:Seventeen head and neck CT image data sets were retrieved from the picture archiving and communicating system of our hospital and were reformed into voxel models. 22 organs were segmented at each data set. The segmented organ masses were compared to the respective age- and gender-specific ICRP reference mass value. Adjustments were made such that segmented and reference mass values coincide within a tolerance of 10%. A dental cone beam CT cleft palate simulation study was set up to demonstrate the applicability of our database to MC frameworks and to investigate the need for age- and gender-specific paediatric models.Results:The designed database covers the age range from 2 months to 14 years old. Each model represents a reference head voxel phantom for its corresponding age and gender category. The simulation study revealed absorbed organ dose differences larger than 50% among the...