Hangyu Zhang

Prof. Hangyu Zhang

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
YYYuan Ying Ying
Yuan Ying Ying
BLBo Liu
Bo Liu
HLHui Li
Hui Li
MLMo Li
Mo Li
YSYingqiu Song
Yingqiu Song
Hangyu ZhangHangyu Zhang
Hangyu Zhang
The popularity of health concepts and the wave of digitalization have driven the innovation of sensors in the medical field. Such continual development has made sensors progress in the direction of safety, flexibility, and intelligence for continuous monitoring of vital signs, which holds considerable promise for changing the way humans live and even treat diseases. To this end, flexible wearable devices with high performance, such as high sensitivity, high stability, and excellent biodegradability, have attracted strong interest from scientists. Herein, a review of flexible wearable sensors for temperature, heart rate, human motion, respiratory rate, glucose, and pH is highlighted. In addition, engineering issues are also presented, focusing on material selection, sensor fabrication, and power supply. Finally, potential challenges facing current technology and future directions of wearable sensors are also discussed.

7 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YZYuhang Zhang
Yuhang Zhang
NLNa Li
Na Li
BLBo Liu
Bo Liu
Hangyu ZhangHangyu Zhang
Hangyu Zhang
In this work, silver nanoparticles (AgNPs)/reduced graphene oxide (rGO) nanocomposites were electrodeposited on glassy carbon electrodes (GCE) to construct electrochemical sensors for the detection of hydrogen peroxide (H2O2) and dopamine (DA). The AgNPs were synthesized on graphene oxide (GO) by the hydrothermal method, followed by the reduction of the GO during the electrodeposition process, resulting in the formation of the nanocomposites on the surface of the electrodes. The generation of AgNPs on the graphene sheets was verified by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). The AgNPs/rGO/GCE showed a linear response to H2O2 in the range of 5 μM to 620 μM, with a sensitivity of 49 μA mM−1cm−2 and a limit of detection (LOD) of 3.19 μA. The linear response of the AgNPs/rGO/GCE to DA ranged from 1 μM to 276 μM, the sensitivity was 7.86 μA mM−1cm−2, and the LOD was 0.18 μM. Furthermore, DA and H2O2 were detected simultaneously in the same solution without interferences, and the sensors displayed good stability over time. The preparation method for the sensors is relatively eco-friendly, convenient, and efficient, exhibiting great potential for sensitive detection of DA and H2O2.

13 October 2021 in Frontiers in Immunology
Verified
Journal Article
Open access
DWDanyang Wang
Danyang Wang
Hangyu ZhangHangyu Zhang
Hangyu Zhang
TXTao Xiang
Tao Xiang
GWGang Wang
Gang Wang
Colorectal cancer (CRC) is one of the most common cancers worldwide. However, the treatment outcomes of immunotherapy in microsatellite-stable (MSS) CRC remain unsatisfactory. As the majority of CRC cases display a molecular MSS/mismatch repair-proficient (pMMR) profile, it is particularly meaningful to explore the clinical applications of adaptive immune therapy in MSS CRC patients. In this review, we summarized the therapeutic approaches of adoptive immune therapies, including cytokines, therapeutic cancer vaccines, adoptive T-cell therapy, and immune checkpoint inhibitors, in the treatment of MSS CRCs.

Verified
Journal Article
Open access
PDF file
CWCunli Wang
Cunli Wang
SSShuai Shao
Shuai Shao
NLNa Li
Na Li
ZZZhengyao Zhang
Zhengyao Zhang
Hangyu ZhangHangyu Zhang
Hangyu Zhang
BLBo Liu
Bo Liu
Alzheimer’s disease (AD) urgently needs innovative treatments due to the increasing aging population and lack of effective drugs and therapies. The amyloid fibrosis of AD-associated β-amyloid (Aβ) that could induce a series of cascades, such as oxidative stress and inflammation, is a critical factor in the progression of AD. Recently, peptide-based therapies for AD are expected to be great potential strategies for the high specificity to the targets, low toxicity, fast blood clearance, rapid cell and tissue permeability, and superior biochemical characteristics. Specifically, various chiral amino acids or peptide-modified interfaces draw much attention as effective manners to inhibit Aβ fibrillation. On the other hand, peptide-based inhibitors could be obtained through affinity screening such as phage display or by rational design based on the core sequence of Aβ fibrosis or by computer aided drug design based on the structure of Aβ. These peptide-based therapies can inhibit Aβ fibrillation and reduce cytotoxicity induced by Aβ aggregation and some have been shown to relieve cognition in AD model mice and reduce Aβ plaques in mice brains. This review summarizes the design method and characteristics of peptide inhibitors and their effect on the amyloid fibrosis of Aβ. We further describe some analysis methods for evaluating the inhibitory effect and point out the challenges in these areas, and possible directions for the design of AD drugs based on peptides, which lay the foundation for the development of new effective drugs in the future.

14 May 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
TZTiancong Zhao
Tiancong Zhao
HZHuichao Zhu
Huichao Zhu
Hangyu ZhangHangyu Zhang
Hangyu Zhang
Flexible pressure sensors are widely applied in tactile perception, fingerprint recognition, medical monitoring, human–machine interfaces, and the Internet of Things. Among them, flexible capacitive pressure sensors have the advantages of low energy consumption, slight signal drift, and high response repeatability. However, current research on flexible capacitive pressure sensors focuses on optimizing the dielectric layer for improved sensitivity and pressure response range. Moreover, complicated and time-consuming fabrication methods are commonly applied to generate microstructure dielectric layers. Here, we propose a rapid and straightforward fabrication approach to prototyping flexible capacitive pressure sensors based on porous electrodes. Laser-induced graphene (LIG) is produced on both sides of the polyimide paper, resulting in paired compressible electrodes with 3D porous structures. When the elastic LIG electrodes are compressed, the effective electrode area, the relative distance between electrodes, and the dielectric property vary accordingly, thereby generating a sensitive pressure sensor in a relatively large working range (0–9.6 kPa). The sensitivity of the sensor is up to 7.71%/kPa−1, and it can detect pressure as small as 10 Pa. The simple and robust structure allows the sensor to produce quick and repeatable responses. Our pressure sensor exhibits broad potential in practical applications in health monitoring, given its outstanding comprehensive performance combined with its simple and quick fabrication method.

10 January 2018 in Journal of Biomedical Materials Research Part A
Verified
Journal Article
Open access
PDF file
SCShijie Cao
Shijie Cao
YJYonghou Jiang
Yonghou Jiang
CLClaire Levy
Claire Levy
SHSean M. Hughes
Sean M. Hughes
Hangyu ZhangHangyu Zhang
Hangyu Zhang
KWKim A. Woodrow
Kim A. Woodrow
Monoclonal antibodies and peptides are conjugated to the surface of nanocarriers (NCs) for targeting purposes in numerous applications. However, targeting efficacy may vary with their specificity, affinity, or avidity when linked to NCs. The physicochemical properties of NCs may also affect targeting. We compared the targeting efficacy of the CD4 binding peptide BP4 and an anti‐CD4 monoclonal antibody (CD4 mAb) and its fragments, when conjugated to lipid‐coated poly(lactic‐co‐glycolic) acid nanoparticles (LCNPs). Negatively charged LCNPs with cholesteryl butyrate in the lipid layer (cbLCNPs) dramatically reduced nonspecific binding, leading to higher targeting specificity, compared to neutral or positively charged LCNPs with DOTAP (dtLCNP). cbLCNPs surface conjugated with a CD4 antibody (CD4‐cbLCNPs) or its fragments (fCD4‐cbLCNPs), but not BP4, showed high binding in vitro to the human T cell line 174xCEM, and preferential binding to CD3+ CD14‐CD8‐ cells from pigtail macaque peripheral blood mononuclear cells. CD4‐cbLCNPs showed 10‐fold higher binding specificity for CD4+ than CD8+ T cells, while fCD4‐cbLCNPs demonstrated the highest binding level overall, but only three‐fold higher binding specificity. This study demonstrates the importance of ζ‐potential on NC targeting and indicates that CD4 mAb and its fragments are the best candidates for delivery of therapeutic agents to CD4+ T cells. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1177–1188, 2018.