The aim of this paper is to investigate control strategies for functional electrical simulation (FES) cycling, with particular focus on the generation of stimulation intensities for multiple muscles, without any predetermined stimulation pattern. The control system is developed by imitating the biological neuronal control system. Specifically, the control signal on the level of joint torque (quasi-joint torque) is generated from the feedback information of lower extremities. The quasi-joint torque is then distributed to each muscle and the muscle delay is compensated, and finally, the stimulation intensity is determined. Parameters of the control system are optimized by the genetic algorithm with cost function of energy consumption and cadence error. The proposed control system is evaluated by computer simulation. The controller generates efficient stimulation even during the muscle fatigue process and successfully continues cycling without any predetermined stimulation pattern. Moreover, the controller is robust to the parameter error in the muscle delay compensator and also to the disturbances. It is expected that the proposed method would improve the FES cycling performance and relieve patients by eliminating the experimental determination of the stimulation patterns.
8 December 2008 in IEEE Transactions on Nuclear Science
In this study, we fabricated a fiber-optic radiation sensor with an organic scintillator to measure the high-energy photon beam from a clinical linear accelerator, and a two-dimensional fiber-optic sensor array to measure high-resolution and real-time dose distributions for small field radiotherapy dosimetry. The scintillating lights generated from each organic sensor probe embedded and arrayed in a water phantom are guided by 10 m plastic optical fibers to the light-measuring device. Two-dimensional photon beam distributions in a water phantom were measured for photon beams with different energies and field sizes. Also, percent depth dose curves for 6 and 15 MV photon beams were obtained.
This study aimed to determine the effects of the binaural beat (BB) on brainwave induction using an inaudible baseline frequency outside the audible frequency range. Experiments were conducted on 18 subjects (11 males [mean age: 25.7 ± 1.6 years] and 7 females [mean age: 24.0 ± 0.6 years]). A BB stimulation of 10 Hz was exerted by presenting frequencies of 18,000 Hz and 18,010 Hz to the left and right ears, respectively. A power spectrum analysis was performed to estimate the mean of the absolute power of the alpha frequency range (8–13 Hz). The variation in the mean alpha power during the rest and stimulation phases in each brain area was compared using the Wilcoxon signed-rank test. Compared to the rest phase, the stimulation phase with BB showed an increasing trend in the mean alpha power across all 5 brain areas. Notably, a significant increase was found in the frontal, central, and temporal areas. This is a significant study in that it determines the effects of only BB without the influence of auditory perception, which has been overlooked in previous studies.
15 November 2007 in Journal of the Korean Physical Society