This randomized clinical trial compares the effects of use vs nonuse of a cerebral embolic protection device during transcatheter aortic valve implantation (TAV
Aortic stenosis is a frequent valvular disease especially in elderly patients. Catheter-based valve implantation has emerged as a valuable treatment approach for these patients being either at very high risk for conventional surgery or even deemed inoperable. The German Aortic Valve Registry (GARY) provides data on conventional and catheter-based aortic procedures on an all-comers basis. A total of 13 860 consecutive patients undergoing repair for aortic valve disease [conventional surgery and transvascular (TV) or transapical (TA) catheter-based techniques] have been enrolled in this registry during 2011 and baseline, procedural, and outcome data have been acquired. The registry summarizes the results of 6523 conventional aortic valve replacements without (AVR) and 3464 with concomitant coronary bypass surgery (AVR + CABG) as well as 2695 TV AVI and 1181 TA interventions (TA AVI). Patients undergoing catheter-based techniques were significantly older and had higher risk profiles. The stroke rate was low in all groups with 1.3% (AVR), 1.9% (AVR + CABG), 1.7% (TV AVI), and 2.3% (TA AVI). The in-hospital mortality was 2.1% (AVR) and 4.5% (AVR + CABG) for patients undergoing conventional surgery, and 5.1% (TV AVI) and AVI 7.7% (TA AVI). The in-hospital outcome results of this registry show that conventional surgery yields excellent results in all risk groups and that catheter-based aortic valve replacements is an alternative to conventional surgery in high risk and elderly patients.
Background—: Learning curves are vigorously discussed and viewed as a negative aspect of adopting new procedures. However, very few publications have methodically examined learning curves in cardiac surgery, which could lead to a better understanding and a more meaningful discussion of their consequences. The purpose of this study was to assess the learning process involved in the performance of minimally invasive surgery of the mitral valve using data from a large, single-center experience. Methods and Results—: All mitral (including tricuspid, or atrial fibrillation ablation) operations performed over a 17-year period through a right lateral mini-thoracotomy with peripheral cannulation for cardiopulmonary bypass (n=3907) were analyzed. Data were obtained from a prospective database. Individual learning curves for operation time and complication rates (using sequential probability cumulative sum failure analysis) and average results were calculated. A total of 3895 operations by 17 surgeons performing their first minimally invasive surgery of the mitral valve operation at our institution could be evaluated. The typical number of operations to overcome the learning curve was between 75 and 125. Furthermore, >1 such operation per week was necessary to maintain good results. Individual learning curves varied markedly, proving the need for good monitoring or mentoring in the initial phase. Conclusions—: A true learning curve exists for minimally invasive surgery of the mitral valve. Although the number of operations required to overcome the learning curve is substantial, marked variation exists between individual surgeons. Such information could be very helpful in structuring future training and maintenance of competence programs for this kind of surgery.
The German Aortic Valve Registry (GARY) seeks to provide information on a real-world, all-comers basis for patients undergoing aortic valve interventions. This registry comprises patients undergoing the complete spectrum of transcutaneous and conventional surgical aortic valve interventions. The aim of this study was to use the GARY registry to evaluate conventional and catheter-based aortic valve interventions in several risk groups. A total of 13 860 consecutive patients undergoing intervention for aortic valve disease [conventional aortic valve replacement (AVR) or transvascular/transapical TAVR (TV-/TA-TAVR)] were enrolled in 78 German centres in 2011. Baseline, procedural and outcome data, including quality of life, were acquired up to 1 year post-intervention. Vital status at 1 year was known for 98.1% of patients. The 1-year mortality rate was 6.7% for conventional AVR patients (n = 6523) and 11.0% for patients who underwent AVR with coronary artery bypass grafting (n = 3464). The 1-year mortality rate was 20.7 and 28.0% in TV- and TA-TAVR patients, respectively (n = 2695 and 1181). However, if patients were stratified into four risk groups by means of the EuroSCORE and the German AV Score, the highest risk cohorts showed the same mortality at 1 year with either therapy. More than 80% of patients in all groups were in the same or better state of health at 1 year post-intervention and were satisfied with the procedural outcome. Conventional AVR surgery yields excellent results after 1 year in lower-risk patients. Catheter-based AVR is a good alternative in high-risk and elderly patients.