In this review paper, we first give a short overview of radiological image guidance in photon radiotherapy, placing emphasis on the fact that linac based radiotherapy has outpaced particle therapy in the adoption of volumetric image guidance. While cone beam computed tomography (CBCT) has been an established technique in linac treatment rooms for almost two decades, the widespread adoption of volumetric image guidance in particle therapy, whether by means of CBCT or in‐room CT imaging, is recent. This lag may be attributable to the bespoke nature and lower number of particle therapy installations, as well as the differences in geometry between those installations and linac treatment rooms. In addition, for particle therapy the so called shift invariance of the dose distribution rarely applies. An overview of the different volumetric image guidance solutions found at modern particle therapy facilities is provided, covering gantry, nozzle, C‐arm, and couch‐mounted CBCT as well different in‐room CT configurations. A summary of the use of in‐room volumetric imaging data beyond anatomy‐based positioning is also presented as well as the necessary corrections to CBCT images for accurate water equivalent thickness calculation. Finally, the use of non‐ionizing imaging modalities is discussed.
The survival of patients with acute lymphoblastic leukemia (ALL) has improved significantly with the use of intensive multimodality treatment regimens including chemotherapy, high‐dose chemotherapy and stem cell rescue, and radiation therapy when indicated. This report summarizes the treatment strategies, especially radiation therapy in the Children's Oncology Group for children with ALL. Currently, radiation therapy is only indicated for children with high‐risk CNS involvement at diagnosis or relapse, testicular relapse and as part of the conditioning regimen for hematopoietic stem cell transplantation. Future research strategies regarding the indications for and dosages of radiation therapy and novel radiation techniques are discussed.
Objective: A ceiling-mounted robotic C-arm cone beam CT (CBCT) system was developed for use with a 190° proton gantry system and a 6-degree-of-freedom robotic patient positioner. We report on the mechanical design, system accuracy, image quality, image guidance accuracy, imaging dose, workflow, safety and collision-avoidance. Methods: The robotic CBCT system couples a rotating C-ring to the C-arm concentrically with a kV X-ray tube and a flat-panel imager mounted to the C-ring. CBCT images are acquired with flex correction and maximally 360° rotation for a 53 cm field of view. The system was designed for clinical use with three imaging locations. Anthropomorphic phantoms were imaged to evaluate the image guidance accuracy. Results: The position accuracy and repeatability of the robotic C-arm was high (<0.5 mm), as measured with a high-accuracy laser tracker. The isocentric accuracy of the C-ring rotation was within 0.7 mm. The coincidence of CBCT imaging and radiation isocentre was better than 1 mm. The average image guidance accuracy was within 1 mm and 1° for the anthropomorphic phantoms tested. Daily volumetric imaging for proton patient positioning was specified for routine clinical practice. Conclusion: Our novel gantry-independent robotic CBCT system provides high-accuracy volumetric image guidance for proton therapy. Advances in knowledge: Ceiling-mounted robotic CBCT provides a viable option than CT on-rails for partial gantry and fixed-beam proton systems with the added advantage of acquiring images at the treatment isocentre.
Objective: To estimate the potential dose reduction in iodinated contrast when interpreting monoenergetic images from spectral CT. Methods: 51 paediatric patients received contrast-enhanced CT simulation for radiation therapy using a single-source, dual-layer detector spectral CT. The contrast-to-noise ratios (CNRs) of blood vessels were measured relative to surrounding soft tissue. CNRs on monoenergetic 40–70 keV images were compared with polychromatic 120 kVp images. To compare with in vivo results, a phantom with iodine inserts (2–20 mg ml–1 concentration) was scanned and CNRs were calculated relative to water background. Results: Monoenergetic keV and body site had significant effects on CNR ratio (p < 0.0001). Across all body sites, the mean CNR ratio (monoenergetic/polychromatic CNR) was 3.3 (20th percentile [%20] 2.6), 2.4 (%20 2.1), 1.7 (%20 1.5), 1.2 (%20 1.0) for 40, 50, 60 and 70 keV images, respectively. Image noise was highest at 40 keV and lowest at 70 keV. Phantom measurements indicated that the same CNR as 120 kVp images can be achieved with a 4.0-fold lower iodine concentration on 40 keV images and 2.5-fold lower on 50 keV images. Conclusion: 50 keV monoenergetic images provided the best balance of improved CNR on all studies (mean 2.4-fold increase in vivo) for enhancing vessels vs image noise. A 50% reduction in contrast dose on a 50 keV image should maintain comparable or better CNR as compared with polychromatic CT in over 80% of CT studies. Advances in knowledge: Use of a novel, single-source, dual-layer detector spectral CT scanner to improve visualization of contrast-enhanced blood vessels will reduce the amount of iodinated contrast required for radiation oncology treatment planning.
7 January 2010 in International Journal of Radiation Oncology, Biology, Physics