Markus Kiffer

Markus Kiffer


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2025 in Physical Review Letters
Verified
Journal Article
Open access
PPPhilip Pfäfflein
Philip Pfäfflein
GWGünter Weber
Günter Weber
SAS. Allgeier
S. Allgeier
ZAZ. Andelkovic
Z. Andelkovic
SBSonja Bernitt
Sonja Bernitt
TSThomas Stöhlker
Thomas Stöhlker
Using novel metallic magnetic calorimeter detectors at the CRYRING@ESR, we recorded x-ray spectra of stored and electron cooled heliumlike uranium ( U 90 + ) with an unmatched spectral resolution of close to 90 eV. This allowed for an accurate determination of the energies of all four components of the K α transitions in U 90 + . We find good agreement with state-of-the-art bound-state QED calculations for the strong-field regime. Our results do not support any systematic deviation between experiment and theory in heliumlike systems, the presence of which was subject of intense debates in recent years.

4 July 2022 in Physica Scripta
Verified
Journal Article
Open access
SRStefan Ringleb
Stefan Ringleb
MKMarkus Kiffer
Markus Kiffer
NSN Stallkamp
N Stallkamp
SKS Kumar
S Kumar
JHJiri Hofbrucker
Jiri Hofbrucker
GPG G Paulus
G G Paulus
We have conceived and built the HILITE (High-Intensity Laser-Ion Trap Experiment) Penning-trap setup for the production, confinement and preparation of pure ensembles of highly charged ions in a defined quantum state as a target for various high-intensity lasers. This enables a broad suite of laser-ion interaction studies at high photon energies and/or intensities, such as non-linear photo-ionisation studies. The setup has now been used to perform experiments at one such laser facility, namely the FLASH Free-Electron Laser at DESY in Hamburg, Germany. We describe the experimental possibilities of the apparatus, the results of the first measurements and future experiments at other laser facilities.

4 March 2024 in Physical Review A
Verified
Journal Article
Open access
PDF file
MKMarkus Kiffer
Markus Kiffer
SRStefan Ringleb
Stefan Ringleb
TSThomas Stöhlker
Thomas Stöhlker
MVManuel Vogel
Manuel Vogel
We have performed systematic measurements of the resistive cooling behavior of bunches of highly charged ions in a Penning trap after injection from an external source. In particular, we have been able to measure the exponential cooling rate of the axial center-of-mass motion and experimentally show its linear dependence on the ion number within the bunch, as expected from theory. The common center-of-mass energy of the ions is reduced by more than four orders of magnitude on the time scale of milliseconds while the single-ion cooling occurs on the scale of seconds, representing a highly effective way to remove the dominating part of the ion kinetic energy. Published by the American Physical Society 2024

1 November 2019 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
MKMarkus Kiffer
Markus Kiffer
SRStefan Ringleb
Stefan Ringleb
NSNils Stallkamp
Nils Stallkamp
BABéla Arndt
Béla Arndt
IBIlya Blinov
Ilya Blinov
MVManuel Vogel
Manuel Vogel
We have devised an experimental method and apparatus for the simultaneous nondestructive determination of the absolute ion number, ion kinetic energy, and length of bunches of charged particles. We have built and operated a corresponding electronic detector that is based on induced charges and their subsequent low-noise amplification at cryogenic temperatures. We have performed measurements with bunches of low-energy highly charged ions from an electron-beam ion source that show the capability of the methods and their implementation. We discuss requirements for, and applications of, such detectors with a particular view on the obtainable information and their sensitivity.

10 May 2024 in The European Physical Journal Plus
Verified
Journal Article
Open access
PDF file
SRStefan Ringleb
Stefan Ringleb
MKMarkus Kiffer
Markus Kiffer
MVManuel Vogel
Manuel Vogel
TSThomas Stöhlker
Thomas Stöhlker
We present a non-destructive electronic detector for stored charged particles in a Penning trap that uses a symmetric electrode arrangement for signal pickup and a resonator without tap. This system has advantageous off-resonance features which are demonstrated by means of detection and cooling measurements with highly charged ions in a cryogenic Penning trap. In particular, it allows for particle detection across a wide range of frequencies that is not concomitant with cooling and offers a novel way to tune a trap with the help of non-destructive measurements on large particle ensembles.

28 January 2023 in Atoms
Verified
Journal Article
Open access
PDF file
FKFelix Martin Kröger
Felix Martin Kröger
GWGünter Weber
Günter Weber
SASteffen Allgeier
Steffen Allgeier
ZAZoran Andelkovic
Zoran Andelkovic
SBSonja Bernitt
Sonja Bernitt
TSThomas Stöhlker
Thomas Stöhlker
We report on a new experimental approach for the Doppler correction of X-rays emitted by heavy ions, using novel metallic magnetic calorimeter detectors which uniquely combine a high spectral resolution with a broad bandwidth acceptance. The measurement was carried out at the electron cooler of CRYRING@ESR at GSI, Darmstadt, Germany. The X-ray emission associated with the radiative recombination of cooler electrons and stored hydrogen-like uranium ions was investigated using two novel microcalorimeter detectors positioned under 0∘ and 180∘ with respect to the ion beam axis. This new experimental setup allowed the investigation of the region of the N, M → L transitions in helium-like uranium with a spectral resolution unmatched by previous studies using conventional semiconductor X-ray detectors. When assuming that the rest-frame energy of at least a few of the recorded transitions is well-known from theory or experiments, a precise measurement of the Doppler shifted line positions in the laboratory system can be used to determine the ion beam velocity using only spectral information. The spectral resolution achievable with microcalorimeter detectors should, for the first time, allow intrinsic Doppler correction to be performed for the precision X-ray spectroscopy of stored heavy ions. A comparison with data from a previous experiment at the ESR electron cooler, as well as the conventional method of conducting Doppler correction using electron cooler parameters, will be discussed.