Tobias Over

Tobias Over


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2022 in Physical Review A
Verified
Journal Article
Open access
PDF file
BZBinghui Zhu
Binghui Zhu
AGAlexandre Gumberidze
Alexandre Gumberidze
TOTobias Over
Tobias Over
GWG. Weber
G. Weber
ZAZ. Andelkovic
Z. Andelkovic
TSThomas Stöhlker
Thomas Stöhlker
For decelerated bare lead ions at a low beam energy of 10 MeV/u, the x-ray emission associated with radiative recombination (RR) at threshold energies has been studied at the electron cooler of CRYRING@ESR at GSI, Darmstadt. In our experiment, we observed the full x-ray emission pattern by utilizing dedicated x-ray detection chambers installed at 0∘ and 180∘ observation geometry. Most remarkably, no line distortion effects due to delayed emission are present in the well-defined x-ray spectra, spanning a wide range of x-ray energies (from about 5 to 100 keV), which enables us to identify fine-structure resolved Lyman, Balmer, and Paschen x-ray lines along with the RR transitions into the K, L, and M shells of the ions. For comparison with theory, an elaborate theoretical model is established taking into account the initial population distribution via RR for all atomic levels up to Rydberg states with principal quantum number n=165 in combination with time-dependent feeding transitions. Within the statistical accuracy, the experimental data are in very good agreement with the results of rigorous relativistic predictions. Most notably, this comparison sheds light on the contribution of prompt and delayed x-ray emission (up to 70 ns) to the observed x-ray spectra, originating in particular from yrast transitions into inner shells.

14 April 2025 in Physical Review Letters
Verified
Journal Article
Open access
PPPhilip Pfäfflein
Philip Pfäfflein
GWGünter Weber
Günter Weber
SAS. Allgeier
S. Allgeier
ZAZ. Andelkovic
Z. Andelkovic
SBSonja Bernitt
Sonja Bernitt
TSThomas Stöhlker
Thomas Stöhlker
Using novel metallic magnetic calorimeter detectors at the CRYRING@ESR, we recorded x-ray spectra of stored and electron cooled heliumlike uranium ( U 90 + ) with an unmatched spectral resolution of close to 90 eV. This allowed for an accurate determination of the energies of all four components of the K α transitions in U 90 + . We find good agreement with state-of-the-art bound-state QED calculations for the strong-field regime. Our results do not support any systematic deviation between experiment and theory in heliumlike systems, the presence of which was subject of intense debates in recent years.

14 October 2022 in Physica Scripta
Verified
Journal Article
Open access
PDF file
PPPhilip Pfäfflein
Philip Pfäfflein
SAS Allgeier
S Allgeier
SBSonja Bernitt
Sonja Bernitt
AFAndreas Fleischmann
Andreas Fleischmann
MFM Friedrich
M Friedrich
TSThomas Stöhlker
Thomas Stöhlker
We report on the first integration of novel magnetic microcalorimeter detectors (MMCs), developed within SPARC (Stored Particles Atomic Physics Research Collaboration), into the experimental environment of storage rings at GSI 6 6 GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstraße 1, 64 291 Darmstadt. , Darmstadt, namely at the electron cooler of CRYRING@ESR. Two of these detector systems were positioned at the 0° and 180° view ports of the cooler section to obtain high-resolution x-ray spectra originating from a stored beam of hydrogen-like uranium interacting with the cooler electrons. While previous test measurements with microcalorimeters at the accelerator facility of GSI were conducted in the mode of well-established stand-alone operation, for the present experiment we implemented several notable modifications to exploit the full potential of this type of detector for precision x-ray spectroscopy of stored heavy ions. Among these are a new readout system compatible with the multi branch system data acquisition platform of GSI, the synchronization of a quasi-continuous energy calibration with the operation cycle of the accelerator facility, as well as the first exploitation of the maXs detectors’ time resolution to apply coincidence conditions for the detection of photons and charge-changed ions.

28 January 2023 in Atoms
Verified
Journal Article
Open access
PDF file
FKFelix Martin Kröger
Felix Martin Kröger
GWGünter Weber
Günter Weber
SASteffen Allgeier
Steffen Allgeier
ZAZoran Andelkovic
Zoran Andelkovic
SBSonja Bernitt
Sonja Bernitt
TSThomas Stöhlker
Thomas Stöhlker
We report on a new experimental approach for the Doppler correction of X-rays emitted by heavy ions, using novel metallic magnetic calorimeter detectors which uniquely combine a high spectral resolution with a broad bandwidth acceptance. The measurement was carried out at the electron cooler of CRYRING@ESR at GSI, Darmstadt, Germany. The X-ray emission associated with the radiative recombination of cooler electrons and stored hydrogen-like uranium ions was investigated using two novel microcalorimeter detectors positioned under 0∘ and 180∘ with respect to the ion beam axis. This new experimental setup allowed the investigation of the region of the N, M → L transitions in helium-like uranium with a spectral resolution unmatched by previous studies using conventional semiconductor X-ray detectors. When assuming that the rest-frame energy of at least a few of the recorded transitions is well-known from theory or experiments, a precise measurement of the Doppler shifted line positions in the laboratory system can be used to determine the ion beam velocity using only spectral information. The spectral resolution achievable with microcalorimeter detectors should, for the first time, allow intrinsic Doppler correction to be performed for the precision X-ray spectroscopy of stored heavy ions. A comparison with data from a previous experiment at the ESR electron cooler, as well as the conventional method of conducting Doppler correction using electron cooler parameters, will be discussed.

4 July 2025 in Atoms
Verified
Journal Article
Open access
PDF file
TOTobias Over
Tobias Over
WMWilko Middents
Wilko Middents
GWGünter Weber
Günter Weber
TSThomas Stöhlker
Thomas Stöhlker
State-of-the-art 2D sensitive semiconductor detectors developed within the SPARC collaboration can be utilized as dedicated Compton polarimeters in the hard X-ray regime. We report on the technique of Compton polarimetry utilizing such a detector and present a method to determine the linear polarization of an analyzed hard X-ray beam by means of Monte-Carlo-simulated data sets.