Gas–Liquid two-phase flows are a common flow in industrial production processes. Since these flows inherently consist of discrete phases, it is challenging to accurately measure the flow parameters. In this context, a novel approach is proposed that combines the pyramidal Lucas-Kanade (L–K) optical flow method with the Split Comparison (SC) model measurement method. In the proposed approach, videos of gas–liquid two-phase flows are captured using a camera, and optical flow data are acquired from the flow videos using the pyramid L–K optical flow detection method. To address the issue of data clutter in optical flow extraction, a dynamic median value screening method is introduced to optimize the corner point for optical flow calculations. Machine learning algorithms are employed for the prediction model, yielding high flow prediction accuracy in experimental tests. Results demonstrate that the gradient boosted regression (GBR) model is the most effective among the five preset models, and the optimized SC model significantly improves measurement accuracy compared to the GBR model, achieving an R2 value of 0.97, RMSE of 0.74 m3/h, MAE of 0.52 m3/h, and MAPE of 8.0%. This method offers a new approach for monitoring flows in industrial production processes such as oil and gas.
9 November 2024 in Flow Measurement and Instrumentation
Flow-induced oscillations widely exist in pipelines, fluid machinery, aerospace, and large-span flexible engineering structures. An inherent energy conversion mechanism can be developed for fluid kinetic energy utilization or acoustic energy harvesting. Fluid-resonant acoustic oscillation is featured by stability, easy operation, and a simple mechanical structure. Acoustic oscillation has high intensity and a mono-frequency, which is beneficial for energy harvesting. A simple cavity with appropriate structural dimensions that can induce fluid-resonant oscillations is set and combined with piezoelectric technology to generate electric power. The energy conversion mechanism is studied numerically and experimentally. The effects of flow velocity on the acoustic frequency, the pressure amplitude, and the output voltage of piezoelectric transducer are analyzed. A stable standing wave acoustic field can be generated in the cavity in a certain range of flow velocity. The results show that the higher intensity acoustic field occurs in the first acoustic mode and the first hydraulic mode and can be obtained in the range of flow velocity 27.1–51.1 m/s when the cavity length is 190 mm. A standing wave acoustic field occurs with a frequency of 490 Hz and a maximum pressure amplitude of 15.34 kPa. The open circuit output voltage can reach 0.286 V using a preliminary transducer. The device designed based on this method has a simple structure and no moving parts. It can harvest the fluid kinetic energy that widely exists in pipelines, engineering facilities, air flow forming around transportation tools, and the natural environment. Its energy output can be provided for the self-powered supply system of low-power sensor nodes in wireless sensor networks.
Accurate micro gas flow measurement is critical for medical ventilator calibration, environmental gas monitoring, and semiconductor manufacturing. Laminar flowmeters are widely employed in micro gas flow measurement applications owing to their inherent advantages of high linearity, the absence of moving components, and a broad measurement range. Nevertheless, due to the low measurement accuracy under micro gas flow caused by nonlinear errors and a relatively complex structure, traditional laminar flow measurement devices exhibit limitations in micro gas flow measurement scenarios. This study proposes a novel micro gas flow measurement method based on a single capillary laminar flow element, which simplifies the structure and enhances applicability in the field of micro gas flow. Through structural optimization with precise control of the capillary length–diameter ratios and theoretical error correction based on computational analysis, nonlinear errors were effectively reduced while improving the measurement accuracy in the field of micro gas flow. The proposed methodology was systematically validated through computational fluid dynamics simulations (ANSYS Fluent 2021 R1) and experimental investigations using a dedicated test platform. The experimental results show that the relative error of the measurement system within the full measurement range is less than ±0.6% (1–10 cm3/min; cm3/min means cubic centimeter per minute), and its accuracy is superior to 1% of reading (1% Rd) or 1.5% of reading (1.5% Rd) of conventional laminar flowmeters. The fitting curve of the flow rate versus the pressure difference derived from the measurement results maintains an excellent linear correlation (R2 > 0.99), thus confirming that this method has practical application value in the field of micro gas flow measurement.
The laminar flow meter (LFM) boasts several advantages such as no moving parts, a wide range ratio, high measurement accuracy, quick dynamic response, etc., and is a promising technology for micro gas flow measurement. In order to explore the influence of different curvature radii on curved surface gap LFM, three curved structures with different curvature radii were designed. The computational fluid dynamics method is applied to simulate the flow feature of three structures. The simulated velocity cloud and pressure distribution show that the larger the curvature radius, the more stable the flow of gas medium. The relationship between differential pressure and volume flow was obtained through the test within a flow range of 0~540 sccm. Regression analysis revealed that the volume flow measured by the curved surface LFM had a high linear relationship with the differential pressure. Experimental findings indicate that differential pressure of the structure with a curvature radius of 2 mm was greater than that of other two structures (curvature radius of 6 mm and 3 mm) at the same point. This indicates that adding the number of surfaces can effectively increase the pressure loss, so as to obtain a larger range ratio, but will increase the measurement error.
Traditional cryogenic air separation units are unsuitable for distributed, small-scale liquid oxygen production. Cryocooler-based liquefaction technology offers an alternative solution, featuring a large cooling capacity, high efficiency, a compact structure, and rapid start–stop capability. In this paper, an oxygen liquefaction system based on a high-capacity Stirling cryocooler was developed. Because the heat transfer performance of cryocoolers varies significantly across different temperature ranges, heat exchanger designs must be tailored to specific operating conditions. However, research on cold-end heat exchangers for large-capacity cryocoolers used in liquefaction systems remains limited. In the liquid oxygen temperature range, factors such as liquid film formation and incomplete condensation severely affect heat transfer performance and must be considered. In this paper, numerical simulations were performed to analyze the condensation behavior of oxygen, with particular attention paid to the matching between the heat exchange structure and the cooling capacity. Subsequently, a small-scale experimental system was constructed and tested. The successful operation of the experimental system validated the feasibility of the proposed heat exchanger design. Under the conditions of 300 K and an oxygen inlet gauge pressure of 0.45 MPa, the system achieved a liquefaction capacity of 7.4 L/h, corresponding to a cooling capacity of 787 W. The specific power consumption was 0.89 kW·h/kg, with a coefficient of performance (COP) of 0.116. This performance is competitive among small-scale cryocooler-based oxygen liquefaction systems. This study provides both theoretical and experimental support for further performance optimization and engineering application of such cryocoolers in liquid oxygen production.