Background:Synthetic bioceramic repair materials have a broad application prospect in bone defect repair because of their excellent bone conductivity and bone induction.Znic Phosphate ceramic particles are commonly used as bone repair material, but there are still problems such as insufficient osteogenesis and potential biological toxicity.Strontium (Sr) has the function of enhancing bone strength. Even in a wide range of ions concentration, they still have a positive impact on osteogenic differentiation.we made a novel type of Sr doped Znic Phosphate ceramic nanoparticles to explore its role in bone regeneration. Methods:Bioactive nanoparticles with Zn and Sr and phosphate (Zn2Sr(PO4)2) were prepared through high temperature solid state method. The characterization analysis for Zn2Sr(PO4)2 nanoparticles was confirmedby TEM observation, EDS mapping ,FTIR, XRD, and XPS .The concentration of released Zn2+,Sr2+ and PO43- was measured by ICP. In vitro,the toxic effect and osteogenic capacity of Zn2Sr(PO4)2 to MC3T3-E1 cells was measured.In vivo ,the ability to promote new bone formation of nanoparticles was tested in rat criticalsized supracondylar femur defect models. Results: In vitro degradation result revealed that the bioactive Zn2+,Sr2+ and PO43- ions were released from nanoparticles in a sustained and stable manner in PBS at 25 oC up to 4 weeks. In vitro osteogenic promotive result showed that the 1/8-1/2 Zn2Sr(PO4)2 nanoparticles cell culture medium extraction,which was at a relatively low concentration, showed superior ability in promoting MC3T3-E1 cell proliferation, osteogenic differentiation, and biomineralization compared to other diluted extract groups and control groups. Finally, 2mg-8mg Zn2Sr(PO4)2 nanoparticles promoted more new bone formation when implanted in the critical sized femoral bone defect (3 mm in diameter) in the rat. Conclusion:The data suggest that the fabricated Zn2Sr(PO4)2 nanoparticles could act as an attractive candidate for bone regeneration.Zn and Sr play a synergistic role in this process,which avoids potential toxic reactions.
Purpose The aim of this study was to determine whether ultrasound guidance can reduce the duration, blood loss volume and invasiveness of surgery for internal fixator removal. Methods The clinical data from 35 adults patients who underwent ultrasound-guided surgical removal of internal fixators after complete healing of limb fractures between June 2019 and April 2023 were retrospectively analysed and compared with those from 34 controls who underwent the procedure without ultrasound guidance. Data concerning the patients' demographic and clinical characteristics and surgical sites were collected. Differences in the patients' demographic and clinical characteristics were compared between the two groups. Results Sixty-nine patients were enrolled in the study. Thirty-five patients underwent surgical removal of internal fixators with ultrasound guidance, and the average intraoperative blood loss volume was 15.17 +/- 18.54 ml, average difference between the incision length and scar length was 4.24 +/- 1.38 cm, average operation time was 60.66 +/- 24.30 min, and average ultrasound assessment time was 10.00 +/- 3.90 min. Thirty-four patients underwent surgical removal of internal fixators without ultrasound guidance, and the average blood loss volume was 46.76 +/- 90.74 ml, average difference between the incision length and scar length was 2.68 +/- 1.04 cm, and average operation time was 80.15 +/- 58.84 min. The difference between the incision length and scar length was significant (P < 0.01), as was the difference in the intraoperative blood loss volume (P < 0.05) between the two groups. Conclusion Ultrasound is a convenient, noninvasive, radiation-free technique that allows dynamic scanning of multiple sections regardless of patient position. Ultrasound-assisted removal of internal fixators might reduce bleeding and therefore the invasiveness of the procedure. Physicians can use ultrasound for preoperative patient positioning, intraoperative monitoring, and postoperative confirmation of complete removal of internal fixators if necessary.