This paper describes a series of field studies and simulation analysis to improve the thermal performance of school buildings in the city of Tehran in Iran during warm season. The field studies used on-site measurement and questionnaire-based survey in the warm spring season in a typical female secondary school building. The on-site monitoring assessed the indoor air temperature and humidity levels of six classrooms while the occupants completed questionnaires covering their thermal sensations and thermal preferences. Moreover, thermal simulation analysis was also carried out to evaluate and improve the thermal performance of the classrooms based on the students’ thermal requirements and passive design strategies. In this study, the environmental design guidelines for female secondary school buildings were introduced for the hot and dry climate of Tehran, using passive design strategies. The study shows that the application of passive design strategies including south and south-east orientation, 10cm thermal insulation in wall and 5cm in the roof, and the combination of 30cm side fins and overhangs as a solar shading devices, as well as all-day ventilation strategy and the use of thermal mass materials with 25cm-30cm thickness, has considerable impact on indoor air temperatures in warm season in Tehran and keeps the indoor environment in an acceptable thermal condition. The results of the field studies also indicated that most of the occupants found their thermal environment not to be comfortable and the simulation results showed that passive design techniques had a significant influence on the indoor air temperature and can keep it in an acceptable range based on the female students’ thermal requirement. Therefore, in order to enhance the indoor environment and to increase the learning performance of the students, it is necessary to use the appropriate passive design strategies, which also reduce the need for mechanical systems and therefore reduce the energy loads of the building.
The UK government has announced its ten-point plan to annually install 600,000 low-carbon heat pumps by 2028. However, there is a lack of evidence showing potential overheating risk in dwellings retrofitted with heat pumps. This paper examines the prevalence and magnitude of summertime overheating across 24 naturally ventilated social housing dwellings retrofitted with ground source heat pumps (GSHPs). The dwellings are located in a socially deprived area in Oxford (UK). The empirical study included longitudinal monitoring of indoor temperatures in the living rooms and bedrooms during the non-heating seasons of 2021 and 2022 (May–September), which included a record-breaking heatwave in July 2022. Indoor temperature and CO2 levels in bedrooms were monitored across a subset of six dwellings alongside the monitoring of window opening state in three bedrooms to understand the effect of natural ventilation in removing excess heat. About 136 thermal comfort surveys were conducted to ascertain the subjective responses of residents. Overheating risk assessment was carried out using CIBSE static and adaptive methods, which revealed that summertime overheating was prevalent across half of the dwellings in the non-heating season of 2022, as compared to 17% overheated dwellings in 2021. Bungalows with upgraded cavity wall insulation and top floor flats facing south and south-west had a propensity to overheat. The variation in indoor temperature and CO2 levels across a small sample also indicated the relationship between overheating and residents’ behaviour. Given that the majority of the dwellings were occupied by retired elderly people with low incomes who are vulnerable to heat and cannot afford active forms of cooling, it is vital to deploy passive design measures, such as appropriate shading devices that are suitable for a heating-dominated climate and enhanced ventilation, as part of home energy retrofits. Implementing reversible heat pumps coupled with solar PVs can provide cooling during heatwaves while delivering low-carbon heat in the winter.
Passive building design can improve energy efficiency of buildings, while providing comfortable indoor environment for occupants with minimum mechanical energy use. The foundation of passive design depends on natural sources of energy, which uses building architecture and surrounding environment to minimise heating and cooling loads of buildings with minimum operating and maintenance costs. The correlation of local climate with shape and thermal performance of buildings is one of the main considerations of passive design approach to reduce energy use and increase thermal comfort of occupants. This paper focuses on a series of field studies and building simulation analysis to improve thermal performance of female secondary school buildings in the city of Tehran in Iran during winter season using passive design strategies. The field studies included measuring indoor air temperature, as well as a questionnaire-based survey in a cold winter season in a typical female secondary school building. The on-site monitoring assessed indoor air temperature of classrooms while the occupants completed questionnaires covering their thermal sensations and thermal preferences. Moreover, building thermal simulation analysis were carried out using DesignBuilder tool to evaluate and improve thermal performance of classrooms based on students' thermal requirements and passive design strategies. The simulation analysis started from the basic school building model, investigating various passive design strategies to predict the optimum design strategies for the case study. The simulation results determined how to provide classrooms that are more comfortable for students with minimum energy use. The results of the field studies indicated that indoor thermal environment were usually comfortable for female students based on 7-point ASHRAE scale. However, most of the occupants preferred their indoor thermal environment to be improved. Moreover, simulation results showed that building fabrics and thermal properties, as well as glazing and orientation had significant impacts on indoor air temperature and thermal comfort and using appropriate passive design strategies could improve energy efficiency of the building considerably. Therefore, in order to enhance indoor thermal environment and to increase learning performance of students, it is necessary to use appropriate low energy methods, which can reduce the needs for mechanical energy systems and hence save energy.
28 November 2019 in Building Services Engineering Research & Technology
This paper uses a case study-based approach to empirically investigate the relationship between indoor environment and workplace productivity in two contrasting office environments: one naturally ventilated, the other mechanically ventilated. Environmental parameters were continuously monitored over 19 months. Transverse and longitudinal surveys recorded occupants’ perception of their working environment and self-reported productivity, while performance tasks (numerical and proofreading) measured cognitive capability as proxy for measured productivity. Indoor temperatures and CO 2 concentrations were found to be higher and more variable in the naturally ventilated office. However, the correlation between occupant perception of their indoor environment and perceived productivity was stronger in the mechanically ventilated office. Occupants of the naturally ventilated office were found to be more tolerant of their environment than their counterparts in the mechanically ventilated office. Task performance was affected by indoor environmental conditions such as indoor temperature and CO 2 concentration. Interestingly in the naturally ventilated office, the median scores were up to 12% higher for tests conducted at CO 2 concentrations <1400 ppm, compared to those conducted above 1400 ppm, whereas in the mechanically ventilated office, this threshold was only 1000 ppm. The study showed that higher concentrations of CO 2 were associated with lower task scores and longer task durations, reinforcing the need for good levels of ventilation in workspaces. It was found that occupants in NV workspaces were able to adapt to a broader range of environmental conditions. Therefore, controlling the indoor environment within narrow ranges (expending significant amounts of energy in the process) may not always be necessary to improve comfort and productivity. On the other hand, controlling indoor environment within a narrow range – as is common in MV workspaces – may be counterproductive, creating occupants who are less tolerant of small changes in their environmental conditions. The study also demonstrates occupant surveys can provide useful feedback on perceived comfort and productivity at relatively low cost. Insights from such surveys can be used to improve indoor environment in workspaces.