CHIEH HSIN TANG

Prof. CHIEH HSIN TANG

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2009 in Applied Ergonomics
Verified
Journal Article
Closed access
CTCHIEH HSIN TANG
CHIEH HSIN TANG
WWWu-Tai Wu
Wu-Tai Wu
CLChing-Yuan Lin
Ching-Yuan Lin

1 March 2008 in Applied Ergonomics
Verified
Journal Article
Closed access
CTCHIEH HSIN TANG
CHIEH HSIN TANG
CLChing-Yuan Lin
Ching-Yuan Lin
YHYu-Min Hsu
Yu-Min Hsu

22 March 2015 in Fire Technology
Verified
Journal Article
Closed access
PDF file
Gary Li-Kai HsiaoGary Li-Kai Hsiao
Gary Li-Kai Hsiao
CTCHIEH HSIN TANG
CHIEH HSIN TANG
THTe-Chin Huang
Te-Chin Huang
CLChing-Yuan Lin
Ching-Yuan Lin

24 September 2009 in Journal of Coatings Technology and Research
Verified
Journal Article
Closed access
PDF file
YCYing-Ji Chuang
Ying-Ji Chuang
CTCHIEH HSIN TANG
CHIEH HSIN TANG
PCPo-Hung Chen
Po-Hung Chen
YCYing-Hung Chuang
Ying-Hung Chuang
CLChing-Yuan Lin
Ching-Yuan Lin

16 August 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
WCWen Yao Chang
Wen Yao Chang
CTCHIEH HSIN TANG
CHIEH HSIN TANG
CLChing-Yuan Lin
Ching-Yuan Lin
Historical buildings often fail to meet today’s building and fire protection regulations due to their structure and space restrictions. For this reason, if such buildings encounter fire, serious damage will be resulted. The fire of the Notre-Dame Cathedral in Paris (Notre-Dame de Paris) in April 2019 highlights the seriousness of this problem. In this study, the historical building of “Tamsui Church” was selected as an example. The Fire Dynamics Simulator (FDS) was adopted to analyze the scale of damage and possible hazards when the wooden seats in the church are on fire, and improvement measures were proposed to ensure that such buildings can be used under safer conditions. It was found that the existing seat arrangement will cause the spreading of fire, and the maximum heat release rate is 2609.88 kW. The wooden roof frame above the fire source will also start to burn at 402.88 s (6.6 min) after the fire, which will lead to a full-scale fire. To maintain the safety of the historical building, it is necessary to add active firefighting equipment (smoke detector and water mist system).

1 August 2005 in Journal of Applied Fire Science
Verified
Journal Article
Closed access
YCYing-Ji Chuang
Ying-Ji Chuang
CTCHIEH HSIN TANG
CHIEH HSIN TANG
PCPo-Hung Chen
Po-Hung Chen
CLChing-Yuan Lin
Ching-Yuan Lin
Metapress is a fast growing digital platform that helps visitors to answer questions, solve problems, learn new skills, find inspiration and provide the latest Technology news.