Amelie Heesch

Ms. Amelie Heesch


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2020 in Cells
Verified
Journal Article
Open access
PDF file
AHAmelie Heesch
Amelie Heesch
Jochen MaurerJochen Maurer
Jochen Maurer
ESElmar Stickeler
Elmar Stickeler
MBMohsen Beheshti
Mohsen Beheshti
FMFelix M. Mottaghy
Felix M. Mottaghy
AMAgnieszka Morgenroth
Agnieszka Morgenroth
Molecular imaging plays an increasingly important role in the diagnosis and treatment of different malignancies. Radiolabeled probes enable the visualization of the primary tumor as well as the metastases and have been also employed in targeted therapy and theranostic approaches. With breast cancer being the most common malignancy in women worldwide it is of special interest to develop novel targeted treatments. However, tumor microenvironment and escape mechanisms often limit their therapeutic potential. Addressing tumor stroma associated targets provides a promising option to inhibit tumor growth and angiogenesis and to disrupt tumor tissue architecture. This review describes recent developments on radiolabeled probes used in diagnosis and treatment of breast cancer especially in triple negative type with the focus on potential targets offered by the tumor microenvironment, like tumor associated macrophages, cancer associated fibroblasts, and endothelial cells.

8 February 2023 in Cells
Verified
Journal Article
Open access
PDF file
AHAmelie Heesch
Amelie Heesch
LOLars Ortmanns
Lars Ortmanns
Jochen MaurerJochen Maurer
Jochen Maurer
ESElmar Stickeler
Elmar Stickeler
SSSabri E. M. Sahnoun
Sabri E. M. Sahnoun
AMAgnieszka Morgenroth
Agnieszka Morgenroth
Recent studies proving prostate-specific membrane antigen (PSMA) expression on triple-negative breast cancer (TNBC) cells and adjacent endothelial cells suggest PSMA as a promising target for therapy of until now not-targetable cancer entities. In this study, PSMA and its isoform expression were analyzed in different TNBC cells, breast cancer stem cells (BCSCs), and tumor-associated endothelial cells. PSMA expression was detected in 91% of the investigated TNBC cell lines. The PSMA splice isoforms were predominantly found in the BCSCs. Tumor-conditioned media from two TNBC cell lines, BT-20 (high full-length PSMA expression, PSMAΔ18 expression) and Hs578T (low full-length PSMA expression, no isoform expression), showed significant pro-angiogenic effect with induction of tube formation in endothelial cells. All TNBC cell lines induced PSMA expression in human umbilical vein endothelial cells (HUVEC). Significant uptake of radiolabeled ligand [68Ga]Ga-PSMA was detected in BCSC1 (4.2%), corresponding to the high PSMA expression. Moreover, hypoxic conditions increased the uptake of radiolabeled ligand [177Lu]Lu-PSMA in MDA-MB-231 (0.4% vs. 3.4%, under hypoxia and normoxia, respectively) and MCF-10A (0.3% vs. 3.0%, under normoxia and hypoxia, respectively) significantly (p < 0.001). [177Lu]Lu-PSMA-induced apoptosis rates were highest in BT-20 and MDA-MB-231 associated endothelial cells. Together, these findings demonstrate the potential of PSMA-targeted therapy in TNBC.

20 February 2024 in Breast Cancer Research
Verified
Journal Article
Open access
PDF file
AHAmelie Heesch
Amelie Heesch
AFAlexandru Florea
Alexandru Florea
JMJochen Maurer
Jochen Maurer
PHPardes Habib
Pardes Habib
LWLaura S. Werth
Laura S. Werth
AMAgnieszka Morgenroth
Agnieszka Morgenroth
Introduction: Overexpression of prostate-specific membrane antigen (PSMA) on the vasculature of triple-negative breast cancer (TNBC) presents a promising avenue for targeted endogenous radiotherapy with [177Lu]Lu-PSMA-I&T. This study aimed to assess and compare the therapeutic efficacy of a single dose with a fractionated dose of [177Lu]Lu-PSMA-I&T in an orthotopic model of TNBC. Methods: Rj:NMRI-Foxn1nu/nu mice were used as recipients of MDA-MB-231 xenografts. The single dose group was treated with 1 × 60 ± 5 MBq dose of [177Lu]Lu-PSMA-I&T, while the fractionated dose group received 4 × a 15 ± 2 MBq dose of [177Lu]Lu-PSMA-I&T at 7 day intervals. The control group received 0.9% NaCl. Tumor progression was monitored using [18F]FDG-PET/CT. Ex vivo analysis encompassed immunostaining, TUNEL staining, H&E staining, microautoradiography, and autoradiography. Results: Tumor volumes were significantly smaller in the single dose (p < 0.001) and fractionated dose (p < 0.001) groups. Tumor growth inhibition rates were 38% (single dose) and 30% (fractionated dose). Median survival was notably prolonged in the treated groups compared to the control groups (31d, 28d and 19d for single dose, fractionated dose and control, respectively). [177Lu]Lu-PSMA-I&T decreased the size of viable tumor areas. We further demonstrated, that [177Lu]Lu-PSMA-I&T binds specifically to the tumor-associated vasculature. Conclusion: This study highlights the potential of [177Lu]Lu-PSMA-I&T for endogenous radiotherapy of TNBC. Graphical

4 October 2024 in Journal of Visualized Experiments
Verified
Journal Article
Closed access
PDF file
BABetül Altunay
Betül Altunay
MBMatthias Bauwens
Matthias Bauwens
LSLaura Schäfer
Laura Schäfer
AHAmelie Heesch
Amelie Heesch
AMAgnieszka Morgenroth
Agnieszka Morgenroth
Alexandru FloreaAlexandru Florea
Alexandru Florea
Small animal Positron Emission Tomography (PET) and Single Photon Emission Computed Tomography (SPECT) imaging techniques are crucial in preclinical cancer research, necessitating meticulous attention to radiotracer synthesis, quality assurance, and in vivo injection protocols. This study presents a comprehensive workflow tailored to enhance the robustness and reproducibility of small animal PET experiments. The synthesis process in the radiochemistry laboratory using 68Ga is detailed, highlighting stringent quality control and assurance protocols for each radiotracer production. Parameters such as concentration, molar activity, pH, and purity are rigorously monitored, aligning with standards applicable to human studies. This methodology introduces streamlined syringe preparation and a custom-designed 30G cannula for precise intravenous injections into mice. Monitoring of animal health during scanning, including temperature and heart rate, ensures their well-being throughout the procedure. Dosages for PET and SPECT scans are predetermined to balance data acquisition with minimizing radiation exposure to animals and researchers. Similarly, CT scans employ pre-programmed settings to limit radiation exposure, especially pertinent in long-term studies assessing treatment effects. By optimizing these steps, the workflow aims to standardize procedures, reduce variability, and enhance the quality of small animal PET/SPECT/CT imaging. This resource provides valuable insights for researchers seeking to improve the accuracy and reliability of preclinical investigations in molecular imaging, ultimately advancing the field.

23 June 2025 in Cancers
Verified
Journal Article
Open access
PDF file
LSLaura Schäfer
Laura Schäfer
BABetül Altunay
Betül Altunay
AHAmelie Heesch
Amelie Heesch
TNThiemo van Nijnatten
Thiemo van Nijnatten
SVSofia Carrilho Vaz
Sofia Carrilho Vaz
FMFelix M. Mottaghy
Felix M. Mottaghy
In this narrative review, we aim to summarize recent advancements in nuclear molecular imaging techniques and their applications in BCa management. The main focus of this review is on the most relevant clinical investigations from the past 2–3 years that highlight the enhanced diagnostic and therapeutic value of these imaging modalities. A variety of radiolabeled probes introduced in molecular imaging is explored, detailing their roles in the accurate diagnosis and characterization of BCa, as well as their integration into radioligand therapy and theragnostic strategies.

5 October 2024
Verified
Dataset
Closed access
PDF file
BABetül Altunay
Betül Altunay
MBMatthias Bauwens
Matthias Bauwens
LSLaura Schäfer
Laura Schäfer
AHAmelie Heesch
Amelie Heesch
AMAgnieszka Morgenroth
Agnieszka Morgenroth
Alexandru FloreaAlexandru Florea
Alexandru Florea
Small animal Positron Emission Tomography (PET) and Single Photon Emission Computed Tomography (SPECT) imaging techniques are crucial in preclinical cancer research, necessitating meticulous attention to radiotracer synthesis, quality assurance, and in vivo injection protocols. This study presents a comprehensive workflow tailored to enhance the robustness and reproducibility of small animal PET experiments. The synthesis process in the radiochemistry laboratory using 68Ga is detailed, highlighting stringent quality control and assurance protocols for each radiotracer production. Parameters such as concentration, molar activity, pH, and purity are rigorously monitored, aligning with standards applicable to human studies. This methodology introduces streamlined syringe preparation and a custom-designed 30G cannula for precise intravenous injections into mice. Monitoring of animal health during scanning, including temperature and heart rate, ensures their well-being throughout the procedure. Dosages for PET and SPECT scans are predetermined to balance data acquisition with minimizing radiation exposure to animals and researchers. Similarly, CT scans employ pre-programmed settings to limit radiation exposure, especially pertinent in long-term studies assessing treatment effects. By optimizing these steps, the workflow aims to standardize procedures, reduce variability, and enhance the quality of small animal PET/SPECT/CT imaging. This resource provides valuable insights for researchers seeking to improve the accuracy and reliability of preclinical investigations in molecular imaging, ultimately advancing the field.