Matthias Lenzner

Dr. Matthias Lenzner

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2016 in Optics Express
Verified
Journal Article
Open access
PDF file
MLMatthias Lenzner
Matthias Lenzner
JDJean-Claude Diels
Jean-Claude Diels
A modified Spatial Heterodyne Spectrometer (SHS) is used for measuring atomic emission spectra with high resolution. This device is basically a Fourier Transform Spectrometer, but the Fourier transform is taken in the directions perpendicular to the optical propagation and heterodyned around one preset wavelength. In recent descriptions of this device, one specific phenomenon - the tilt of the energy front of wave packets when diffracted from a grating - was neglected. This led to an overestimate of the resolving power of this spectrograph, especially in situations when the coherence length of the radiation under test is in the order of the effective aperture of the device. The limits of usability are shown here together with some measurements of known spectral lines.

22 December 2016 in Optics Express
Verified
Journal Article
Open access
PDF file
JHJames Hendrie
James Hendrie
MLMatthias Lenzner
Matthias Lenzner
HAHanieh Afkhamiardakani
Hanieh Afkhamiardakani
Jean-Claude DielsJean-Claude Diels
Jean-Claude Diels
LALadan Arissian
Ladan Arissian
Intracavity phase interferometry is a phase sensing technique using mode-locked lasers in which two intracavity pulses circulate. The beat frequency between the two output frequency combs is proportional to a phase shift to be measured. A laser gyro is a particular implementation of this device. The demonstrated sensitivity of 10−8 of these devices could be manipulated by applying a giant dispersion to each tooth of the comb. It is shown that the resonant dispersion of a Fabry-Perot inserted in the cavity couples to the modes of the frequency comb, resulting in a large change in phase response.

17 April 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
MLMatthias Lenzner
Matthias Lenzner
JDJean-Claude Diels
Jean-Claude Diels
A spectrometer based on a Sagnac interferometer, where one of the mirrors is replaced by a transmission grating, is introduced. Since the action of a transmission grating is reversible, both directions experience the same diffraction at a given wavelength. At the output, the crossed wavefronts are imaged onto a camera, where their Fizeau fringe pattern is recorded. Each spectral element produces a unique spatial frequency, hence the Fourier transform of the recorded interferogram contains the spectrum. Since the grating is tuned to place zero spatial frequency at a selected wavelength, the adjoining spectrum is heterodyned with respect to this wavelength. This spectrum can then be discriminated at a high spectral resolution from relatively low spatial frequencies. The spectrometer can be designed without moving parts for a relatively narrow spectral range or with a rotatable grating. The latter version bears the potential to be calibrated without a calibrated light source.

1 January 2018
Verified
Conference Paper
Closed access
PDF file
ARAli Rastegari
Ali Rastegari
MLMatthias Lenzner
Matthias Lenzner
LALadan Arissian
Ladan Arissian
JDJean-Claude Diels
Jean-Claude Diels
KPKristen Peterson
Kristen Peterson
The shock wave created by a high energy UV filament is sufficient to create a low density region in the ablation plume enabling higher resolution in laser induced breakdown spectroscopy. Isotopic selectivity is demonstrated.

28 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
XZXiaobing Zhu
Xiaobing Zhu
MLMatthias Lenzner
Matthias Lenzner
Jean-Claude DielsJean-Claude Diels
Jean-Claude Diels
This study addresses any sensor based on measuring a physical quantity through the phase of a probing beam. This includes sensing of rotation, acceleration, index change, displacement, fields… While most phase measurements are made by detecting an amplitude change in interfering beams, we detect instead a phase change through a relative frequency shift of two correlated frequency combs. This paper explores the limit sensitivity that this method can achieve, when the combs are generated in an Optical Parametric Oscillator (OPO), pumped synchronously by a train of femtosecond pulses separated by half the OPO cavity round-trip time. It is shown that a phase difference as small as 0.4 nanoradians can be resolved between the two pulses circulating in the cavity. This phase difference is one order of magnitude better than the previous record. The root-mean-square deviation of the measured phase over measuring time is close to the standard quantum limit (phase-photon number uncertainty product of 0.66). Innovations that made such improved performances possible include a more stable OPO cavity design; a stabilization system with a novel purely electronic locking of the OPO cavity length relative to that of the pump laser; a shorter pump laser cavity; and a square pulse generator for driving a 0.5 mm pathlength lithium niobate phase modulator. Future data acquisition improvements are suggested that will bring the phase sensitivity exactly to the standard quantum limit, and beyond the quantum limit by squeezing.

23 April 2022 in Optical Engineering
Verified
Journal Article
Open access
PDF file
AOAmir Khabazzi Oskouei
Amir Khabazzi Oskouei
MLMatthias Lenzner
Matthias Lenzner
LELuke A. Emmert
Luke A. Emmert
MJMarco Jupé
Marco Jupé
TWThomas Willemsen
Thomas Willemsen
WRWolfgang Rudolph
Wolfgang Rudolph
We propose a figure of merit that characterizes the femtosecond laser damage behavior of optical coatings. This figure of merit, based on the complete spatiotemporal evolution of the field in a multilayer system, can be included in optics design. The monochromatic intensity enhancement widely used in “electric field-engineering” is sufficient only in certain structures such as high-reflectivity quarter-wave mirrors. In more complex systems, for example, in group delay dispersion mirrors and frequency tripling mirrors, one should consider the actual (typically smaller) intensity enhancement produced by short pulses and the change (typically increase) of pulse duration within the stack.