Joan Antoni Gómez-Hospital

Dr. Joan Antoni Gómez-Hospital

1. Interventional Cardiology Department, Hospital Universitari de Bellvitge, 08907 L'Hospitalet de Llobregat, Barcelona, Spain
+1
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
GRGerard Roura
Gerard Roura
AAAlbert Ariza-Solé
Albert Ariza-Solé
IRIda Fabiola Rodriguez-Caballero
Ida Fabiola Rodriguez-Caballero
JGJosep Gomez-Lara
Josep Gomez-Lara
JFJose Luis Ferreiro
Jose Luis Ferreiro
ACAngel Cequier
Angel Cequier

30 March 2024 in European Heart Journal
Verified
Journal Article
Open access
PDF file
DFDerk Frank
Derk Frank
EDEric Durand
Eric Durand
SLSandra Lauck
Sandra Lauck
DMDouglas F Muir
Douglas F Muir
MSMark Spence
Mark Spence
GMGemma McCalmont
Gemma McCalmont
There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety. BENCHMARK: streamlined transcatheter aortic valve implantation (TAVI) pathway with retained safety. CCU, coronary care unit; ICU, intensive care unit; GW, general ward; IMC, intermediate care; PPM, permanent pacemaker. *Includes patients with available data on LoS only.

10 December 2021 in European Heart Journal
Verified
Journal Article
Open access
PDF file
RRRafael Romaguera
Rafael Romaguera
PSPablo Salinas
Pablo Salinas
JGJosep Gomez-Lara
Josep Gomez-Lara
SBSalvatore Brugaletta
Salvatore Brugaletta
AGAntonio Gómez-Menchero
Antonio Gómez-Menchero
ACAngel Cequier
Angel Cequier
Patients with diabetes mellitus are at high risk of adverse events after percutaneous revascularization, with no differences in outcomes between most contemporary drug-eluting stents. The Cre8 EVO stent releases a formulation of sirolimus with an amphiphilic carrier from laser-dug wells, and has shown clinical benefits in diabetes. We aimed to compare Cre8 EVO stents to Resolute Onyx stents (a contemporary polymer-based zotarolimus-eluting stent) in patients with diabetes. We did an investigator-initiated, randomized, controlled, assessor-blinded trial at 23 sites in Spain. Eligible patients had diabetes and required percutaneous coronary intervention. A total of 1175 patients were randomly assigned (1:1) to receive Cre8 EVO or Resolute Onyx stents. The primary endpoint was target-lesion failure, defined as a composite of cardiac death, target-vessel myocardial infarction, and clinically indicated target-lesion revascularization at 1-year follow-up. The trial had a non-inferiority design with a 4% margin for the primary endpoint. A superiority analysis was planned if non-inferiority was confirmed. There were 106 primary events, 42 (7.2%) in the Cre8 EVO group and 64 (10.9%) in the Resolute Onyx group [hazard ratio (HR): 0.65, 95% confidence interval (CI): 0.44–0.96; P non-inferiority < 0.001; P superiority = 0.030]. Among the secondary endpoints, Cre8 EVO stents had significantly lower rate than Resolute Onyx stents of target-vessel failure (7.5% vs. 11.1%, HR: 0.67, 95% CI: 0.46–0.99; P = 0.042). Probable or definite stent thrombosis and all-cause death were not significantly different between groups. In patients with diabetes, Cre8 EVO stents were non-inferior to Resolute Onyx stents with regard to target-lesion failure composite outcome. An exploratory analysis for superiority at 1 year suggests that the Cre8 EVO stents might be superior to Resolute Onyx stents with regard to the same outcome. ClinicalTrials.gov: NCT03321032. In the SUGAR trial, 1175 patients with diabetes mellitus and coronary artery disease were randomly assigned to receive Cre8 EVO or Resolute Onyx stents. Patients allocated to Cre8 EVO stents had a reduced risk of target lesion failure at 1-year follow-up.

1 February 2014 in EuroIntervention
Verified
Journal Article
Closed access
JGJosep Gomez-Lara
Josep Gomez-Lara
LTLuis Teruel
Luis Teruel
SHSilvia Homs
Silvia Homs
JFJose Luis Ferreiro
Jose Luis Ferreiro
RRRafael Romaguera
Rafael Romaguera
ACAngel Cequier
Angel Cequier
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)

4 July 2017 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
AMAndrea Di Marco
Andrea Di Marco
IAIgnasi Anguera
Ignasi Anguera
LTLuis Teruel
Luis Teruel
GMGuillem Muntane
Guillem Muntane
NCNiall G. Campbell
Niall G. Campbell
ACAngel Cequier
Angel Cequier