The validity of the frequency selection method (FSM) in shallow (<150 m) groundwater exploration was illustrated by practical applications, and the relationship between potential electrode spacing MN and groundwater depth in FSM sounding method was analyzed and preliminary theoretical research was carried out by a simple geologic-geophysical model of sphere. Firstly, under the combined action of horizontal alternating electric field and alternating magnetic field, a simplified geophysical model of low resistivity conductive sphere in homogeneous half space was established, and the forward calculation was performed on the FSM sounding curve. Then, the water yield of 131 wells in the application of FSM in the Rural Drinking Water Safety Project of 12th Five-Year Plan in Guangxi Province was counted. In addition, detailed tabular statistical analysis was carried out on the drilling results of 98 drilling wells, and the relationship between potential electrode spacing MN at abnormal sounding curve and actual drilling water depth was compared and studied. Theoretical analysis and practical application show that FSM has obvious effectiveness in shallow groundwater exploration, and it is an effective method to determine shallow groundwater well locations in the future. The cause of FSM anomaly is the comprehensive effect of the natural 3D alternating electromagnetic signal underground. At the same time, the practical statistics show that there is 1:1 approximation between the size of potential electrode spacing MN at the anomaly curve of the frequency selection method and the actual drilling water depth, which verifies the correctness of the theoretical simulation results. FSM could be widely used in the shallow groundwater exploration in the future, and it is an effective, non-destructive, fast, and low-cost geophysical method.
Geosynthetic clay liners (GCLs) are often used as anti-seepage systems in landfills and at the bottom of tailing ponds. The anti-seepage performance of GCL will change under different temperatures. In this study, bentonite was mixed with test solutions at different temperatures to measure the basic performance indexes of bentonite components and analyze the permeability. The composition and micro-structure of bentonite at different temperatures were analyzed by X-ray diffraction, X-ray fluorescence spectrum, and SEM, and the change rule of permeability property with the mine leachates at different temperatures was understood by combining the macro-measured parameters with the microscopic analysis results. The research results indicate that the fluid loss of two bentonites increased with the increasing temperature due to the inhibition of ion exchange between bentonite and mixture by the increased temperature. The swelling index of the bentonite increased at high temperatures. The micro-structure analysis showed the increase of the pore size attributed to high temperature, and the uneven distribution of the pore size resulted in the increase of the intrinsic permeability. The study would provide the reference for the application of GCL in mining.
Leakage in the impervious layer of a domestic waste landfill seriously pollutes the soil and groundwater. Therefore, it is necessary to carry out rapid nondestructive leakage location detection. In this research, the electrical resistivity tomography (ERT) method and the opposing-coils transient electromagnetic method (OCTEM) were used to detect the leakage location. The inversion sections of both methods showed a clear low–middle–high resistivity spectrum in the longitudinal direction that could be used to speculate the distribution pattern of the upper waste body layer, the bottom impermeable layer, and the lower limestone layer. The leakage area was identified in Zone B of the landfill on the basis of inversion results and drilling verification results. The results indicate that OCTEM and ERT were both sensitive to leakage detection. However, OCTEM had higher longitudinal resolution and more refined inversion results, resulting in more effective delineation for the location of the damage and leakage of the impervious landfill layer, thereby providing a new technical basis for landfill leakage detection.
Natural electric field frequency selection method was proposed by Chinese scholars in the 1980s on the basis of imitating the field observation method of the magnetotelluric method (MT). It can only measure the magnetotelluric field components of one or several frequencies on the surface to determine the existence of underground geological bodies. This method has played an important role in shallow groundwater exploration. This paper mainly discusses the application of frequency selection method in the exploration of underground hot water in the Maoyanhe Scenic spot, Zhangjiajie City, Hunan Province, in order to illustrate the effectiveness of the frequency selection method in water exploration. According to the situation of the construction site, nearly 20 geophysical prospecting survey lines of varying lengths were laid flexibly within the red line of the Maoyan River Scenic Spot. Firstly, three-frequency (170 Hz, 67 Hz and 25 Hz) measurements were carried out on each survey line to preliminarily determine the possible horizontal location of underground hot water. Secondly, in the vicinity of the low potential anomaly of the three-frequency curve, the fine measurement by using multi-frequency bipolar profile method was further carried out. The specific distribution of underground hot water was determined based on the principle of frequency domain sounding and the static effect characteristics of the electromagnetic method so as to provide a scientific basis for the drilling layout. Finally, the reliability of the frequency selection method is verified by two verification boreholes. The results indicate that the frequency selection method is one of the effective geophysical exploration methods in groundwater exploration.