Hao Shao

Dr. Hao Shao


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2017 in Energies
Verified
Journal Article
Open access
PDF file
Weijie YanWeijie Yan
Weijie Yan
YYYunqi Ya
Yunqi Ya
FDFeng Du
Feng Du
HSHao Shao
Hao Shao
PZPt Zhao
Pt Zhao
A portable spectrometer system that simultaneously measures the temperature, emissivity, and radiation intensity of an alkali metal was used in a 1000 MW coal-fired power plant boiler furnace. A calibrated fiber-optic spectrometer system was applied to obtain the radiation intensity of the flame. A simple method based on polynomial fitting was used to separate the continuous baseline from the measured flame spectra that contained both continuous and discontinuous bands. Nine synthetic spectra that included the baseline, noise, and three simulated discontinuous bands based on a Gaussian function were created to test the accuracy of the separation method. The accuracy of the estimated continuous baseline was evaluated by the goodness-of-fit coefficient quality metric. The results indicated good spectral matching for the selected profiles. The soot emissivity model by Hottel and Broughton was employed to calculate temperature and emissivity. The influence of discontinuous emission spectra on the temperature and emissivity calculations was evaluated. The results showed that the maximum difference of the measurement points of the calculated temperature was only 6 K and that the relative difference in emissivity among the measurement points was less than 5%. In addition, a comparison between the actual intensity of the alkali metal and the calculated temperature indicated that the change in the radiation intensity of the alkali metal followed the trend of the calculated temperature. This study serves as a preliminary investigation for measuring gas-phase alkali metal concentrations in a furnace.

6 August 2018 in Combustion Science and Technology
Verified
Journal Article
Closed access
LPLi Pengfei
Li Pengfei
HSHao Shao
Hao Shao
JSJiang Shuguang
Jiang Shuguang
WZWu Zhengyan
Wu Zhengyan
CCCui Chuanbo
Cui Chuanbo
SXShi Xumao
Shi Xumao
In underground collieries, wide application of traditional inhibitors needs a large quantity of water, and there is a problem on getting water nearby. A sloping terrain leads to an uneven distribution of inhibitor solution concentration because of its fluidity. With the loss of water, traditional inhibitors are out of effect. To solve the above three issues, crystalliferous water-containing mineral salts, Na2S2O3 5H2O, CaCl2 6H2O, MgCl2 6H2O and their compound inhibitors, were used to inhibit coal samples in this study. Inhibited coal samples were heated in a programmed heating device, and Fourier transform infrared spectra of coal samples before and after the treatment were made. The results show that the inhibition mechanisms of crystalliferous water-containing mineral salts are a combination of physical and chemical ones, and CaCl2 6H2O is the most effective inhibitor among the crystalliferous water-containing mineral salt inhibitors selected in this study. Compared to the raw coal sample, not only does CaCl2 6H2O reduce the amount of CO generated from heated coal samples, but also it prevents functional groups of coal from being oxidized in the process of oxidation. Furthermore, from the perspective of functional groups, the inhibitory and catalytic effects of MgCl2 6H2O on coal were interpreted. Among compound inhibitors, the one made of Na2S2O3 5H2O, CaCl2 6H2O and MgCl2 6H2O with a mass ratio of 1: 1: 1 is the most effective. The coal sample treated with the compound inhibitor released less CO, but lots of functional groups (–OH,–CH2–, etc.) are converted into the C–O group. Finally, the analysis reveals that CaCl2 6H2O has the best inhibitory effect.

21 December 2022 in Combustion Science and Technology
Verified
Journal Article
Closed access
HSHao Shao
Hao Shao
HHHuan Hu
Huan Hu
SJShuguang Jiang
Shuguang Jiang
ZWZhengyan Wu
Zhengyan Wu
The study investigated the deflagration and detonation suppression effect by different thicknesses of metal foam. The results show that the gas explosion suppression effect of metal foam is related to the explosion stage and the metal foam thickness. In the deflagration stage, the flame could be quenched by 10 mm, 20 mm, and 30 mm thick metal foam. In the flame acceleration stage, the flame can only be quenched by the 30 mm thick metal foam. In the detonation stage, detonation could be completely quenched by 20 mm or 30 mm thick metal foam. Ten-millimeter-thick metal foam could make detonation stage convert into deflagration stage and overpressure decreases obviously. Different propagation mechanisms of deflagration and detonation lead to different suppression effects of foam metal.

13 January 2020 in Combustion Science and Technology
Verified
Journal Article
Closed access
HSHao Shao
Hao Shao
QLQingzi Lu
Qingzi Lu
SJShuguang Jiang
Shuguang Jiang
The frequency conversion ventilation has achieved good results in the practical application of preventing the gas concentration of the coal mining face exceeding the limit. However, its impact on the spontaneous combustion of coal in the goaf is uncertain. Therefore, this paper studies the spontaneous combustion of three types of coal samples at different ventilation rates under frequency conversion ventilation. The results show that frequency conversion ventilation can reduce the average CO concentration compared with constant ventilation, and the inhibiting effect will weaken with the average ventilation rate increased. In three variable frequency ventilation rates, the rate of 10-30-50cm3/min has the best inhibiting effect. At this condition, the inhibiting effect is related to the type of coal, the inhibition rate on anthracite and lignite is proportional to the temperature, while the inhibition rate on bituminous coal is inversely proportional to the temperature. During one cycle around 120°C, the heat released by the oxidation reaction of bituminous coal, lignite, and anthracite decreased by 0.030 J/g, 0.144 J/g, and 0.034 J/g, respectively. Thus, the frequency conversion ventilation can affect the elementary reaction of coal, resulting in a reduction in the heat release from the coal oxidation reaction.

23 January 2023 in Combustion Science and Technology
Verified
Journal Article
Closed access
HSHao Shao
Hao Shao
HHHuan Hu
Huan Hu
QLQingzi Lu
Qingzi Lu
SJShuguang Jing
Shuguang Jing
XPXiaodong Pei
Xiaodong Pei
ZWZhengyan Wu
Zhengyan Wu
Grouting Fire Prevention technology is the most commonly used technology in coal mines. In order to improve the water holding capacity of the slurry and prevent the cracking and re-leakage of air caused by the loss of water, this paper used sodium alginate, sodium polyacrylate and gasification slag to prepare thick paste mixture, and then used calcium chloride to induce the gelation of the mixed paste surface to form an elastic solid film. A kind of environmental protection slurry of coated gasification slag (hereinafter referred to as coated slurry) with good environmental protection, high strength and elastic solid film with flame retardant and water retention on the outer surface was developed. In the 30°C-300°C range, when the coated slurry was heated, it would have a significant heat absorption and cooling effect. The results show that the hydrophilic -COO-, -OH in sodium alginate forms a synergistic effect with -COO-, -COOH in sodium polyacrylate, and enhances the water absorption of sodium polyacrylate; The interaction of calcium ions with sodium alginate on the surface of the mixed slurry causes gelation and forms a calcium alginate film on the surface of the coated slurry, which prevents water evaporation.

23 February 2016 in International Journal of Spray and Combustion Dynamics
Verified
Journal Article
Open access
HSHao Shao
Hao Shao
SJShuguang Jiang
Shuguang Jiang
WZWu Zhengyan
Wu Zhengyan
ZWZhang Weiqing
Zhang Weiqing
WKWang Kai
Wang Kai
A vacuum chamber is used as a new method to suppress gas explosion. Explosion propagation characteristics were studied in a system composed of rectangular pipes and a vacuum chamber. The volume of the vacuum chamber was adjusted by inserting PVC sheets into it. Two groups of explosion suppression experiments were conducted. In one group, the distance between the vacuum chamber and the explosive source point was 3 m and in the other group, this distance was 4 m. The results demonstrated that the effect of explosion suppression of the vacuum chamber is related to the vacuum chamber’s critical volume. When the volume of the vacuum chamber was greater than the critical volume, the chamber exhibited a good explosion suppression effect. When the volume of the vacuum chamber was less than the critical volume, it could not suppress the explosion, and the explosive pressure and flame were stronger than those measured in the absence of the vacuum chamber. On the basis of the experimental results, we further analyzed the suppression mechanism of the vacuum chamber and concluded that stretching of the explosion flame front as well as alteration of the composition of the explosive gas led to the explosive flame being extinguished.