Pinchuan Chen

Prof. Pinchuan Chen

Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2014 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
Pinchuan ChenPinchuan Chen
Pinchuan Chen
CPChang-Wei Pan
Chang-Wei Pan
WLWei-Chen Lee
Wei-Chen Lee
KLKuan-Ming Li
Kuan-Ming Li

1 March 2019 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
LDLynh Huyen Duong
Lynh Huyen Duong
Pinchuan ChenPinchuan Chen
Pinchuan Chen
The use of three-dimensional (3D) printing for the fabrication of microfluidic chips has attracted considerable attention among researchers. This low-cost fabrication method allows for rapid prototyping and the creation of complex structures; however, these devices lack optical transparency, which greatly hinders the characterization and quantification of experiment results. To address this problem, integrating a transparent substrate with a 3D-printed chip is an effective approach. In this study, we present a solvent bonding method of poly(methyl methacrylate) (PMMA) and acrylonitrile butadiene styrene (ABS) thermoplastic materials for the creation of optically detectable 3D-printed microfluidic devices. To achieve an excellent bonding between PMMA and ABS substrates, we used spray coating as a method for the distribution of ethanol solution followed by UV exposure and post-annealing step to improve the bonding strength. We fabricated a microfluidic chip with S-microchannel to characterize the bonding protocol, and other two application-oriented microfluidic chips, including a 3D split-and-recombine-based passive micromixer, and an integrated microchip for the mixing of two streams of liquid prior to the formation of double-emulsion droplets, to evaluate the efficacy of the proposed scheme. As a result, at least eight bars of the bonding strength between PMMA/ABS substrates was achieved, and the ability of producing optically detectable 3D-printed microfluidic devices based on this bonding method was confirmed.

9 January 2014 in International Journal of Precision Engineering and Manufacturing
Verified
Journal Article
Closed access
PDF file
Pinchuan ChenPinchuan Chen
Pinchuan Chen
CPChang-Wei Pan
Chang-Wei Pan
WLWei-Chen Lee
Wei-Chen Lee
KLKuan-Ming Li
Kuan-Ming Li

28 June 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
Pinchuan ChenPinchuan Chen
Pinchuan Chen
YCYi-Pin Chang
Yi-Pin Chang
RZRen-Hao Zhang
Ren-Hao Zhang
CWChun-Chieh Wu
Chun-Chieh Wu
GTGeo-Ry Tang
Geo-Ry Tang
The paper presents a novel and economic manufacturing process for microlens arrays (MLAs). This process uses micromilling machining, PDMS casting, and hybrid bonding between a glass substrate and PDMS membrane to create a microfluidic chip which is used for manufacturing MLAs on a PDMS substrates. MLAs of various diameters were fabricated for experiments, including 1000 μm, 500 μm, and 200 μm. The sag height of the MLAs is easily adjusted by controlling the pressure inside the microchannel to deform the PDMS membrane. Multiple experiments were conducted to characterize the performance of MLAs, the results of which demonstrate: (1) this fabrication process is able to manufacture MLAs with various dimensions and the diameter of an MLAs is determined by the size of micromilling bit and cutting path; (2) the sag height and curvature of MLAs can be controlled by the PDMS membrane thickness and the hydraulic pressure inside the microchannel; (3) an optical system was built to investigate the uniformity of MLAs and the experiment results showed uniform focal length of MLAs; (4) the resulting MLAs magnify tiny objects and significantly enhance the fluorescence signal emitted from the microchannel

24 February 2016 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
Pinchuan ChenPinchuan Chen
Pinchuan Chen
YLYu-Min Liu
Yu-Min Liu
HCHuang-Chieh Chou
Huang-Chieh Chou
Thermoplastics are widely used in the fabrication of microfluidic chips, due to their low cost, flexibility in manufacturing, and applicability in large-scale production. This paper presents a novel bonding method for the assembly of thermoplastic microfluidic chips, with the aim of preventing the flow of UV adhesive into microchannels during the bonding process. The proposed bonding methodology depends primarily on controlling the thickness of the UV adhesive, which is achieved by using spin-coating for the uniform UV adhesive in conjunction with the microfabrication of short pillars for keeping a uniform gap between the two bonded surfaces. In this study, two devices with serpentine microchannels (cross-sectional area of 500 μm × 500 μm and 200 μm × 200 μm) were fabricated on PMMA substrates using a micromilling machine, whereupon a hydrophobic coating was applied to the walls of 200 μm × 200 μm microchannels in order to prevent clogging, which might otherwise be caused by the seepage of UV adhesive into the channels. A variety of experiments were used to characterize the quality of bonding, the results of which reveal the following: (1) no leakage was observed in either of the microfluidic chips; (2) the hydrophobic coating proved highly effective in preventing the flow of UV adhesive into the smaller microchannels; (3) the average amount of clogging inside 500 μm × 500 μm microchannels was 1.13% with standard deviation of 0.55%, while the average amount of clogging inside 200 μm × 200 μm microchannels was 1.65% with standard deviation of 0.92%; (4) the average thickness of the UV adhesive in a 500 μm × 500 μm microfluidic chip was 32 μm with standard deviation of 2 μm, whereas the average thickness of the UV adhesive in a 200 μm × 200 μm microfluidic chip was 31 μm with standard deviation of 1.2 μm; (5) the two chips possess sufficient bonding strength to withstand pressure of at least 10 bar.

12 April 2015 in International Journal of Precision Engineering and Manufacturing
Verified
Journal Article
Closed access
PDF file
Pinchuan ChenPinchuan Chen
Pinchuan Chen
YCYu-Chieh Chen
Yu-Chieh Chen
CPChang-Wei Pan
Chang-Wei Pan
KLKuan-Ming Li
Kuan-Ming Li