Rogerio Bataglioli

Dr. Rogerio Bataglioli

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Applied Surface Science
Verified
Journal Article
Closed access
JNJ.B.M. Rocha Neto
J.B.M. Rocha Neto
TTThiago Bezerra Taketa
Thiago Bezerra Taketa
RBRogerio Bataglioli
Rogerio Bataglioli
SPS.B. Pimentel
S.B. Pimentel
DSD.M. Santos
D.M. Santos
MBM.M. Beppu
M.M. Beppu

1 June 2019 in Journal of Environmental Chemical Engineering
Verified
Journal Article
Closed access
BCBruno S. Cunha
Bruno S. Cunha
RBRogerio Bataglioli
Rogerio Bataglioli
TTThiago Bezerra Taketa
Thiago Bezerra Taketa
LLLaise M. Lopes
Laise M. Lopes
MBMarisa M. Beppu
Marisa M. Beppu

16 October 2020 in Langmuir
Verified
Journal Article
Closed access
RBRogerio Bataglioli
Rogerio Bataglioli
JNJoão Batista M. Rocha Neto
João Batista M. Rocha Neto
BLBruno S. Leão
Bruno S. Leão
LGLuiz Guilherme L. Germiniani
Luiz Guilherme L. Germiniani
TTThiago Bezerra Taketa
Thiago Bezerra Taketa
MBMarisa M. Beppu
Marisa M. Beppu

26 June 2020 in Cells
Verified
Journal Article
Open access
PDF file
JNJoão Batista Rocha Neto
João Batista Rocha Neto
Andrey Coatrini SoaresAndrey Coatrini Soares
Andrey Coatrini Soares
RBRogerio Bataglioli
Rogerio Bataglioli
OCOlívia Carr
Olívia Carr
CCCarlos Costa
Carlos Costa
Hernandes CarvalhoHernandes Carvalho
Hernandes Carvalho
The increasing need for point-of-care diagnosis has sparked the development of label-free sensing platforms, some of which are based on impedance measurements with biological cells. Here, interdigitated electrodes were functionalized with layer-by-layer (LbL) films of hyaluronan (HA) and chitosan (CHI) to detect prostatic tumor cells (PC3 line). The deposition of LbL films was confirmed with atomic force microscopy and polarization-modulated infrared reflection absorption spectroscopy (PM-IRRAS), which featured the vibrational modes of the HA top layer capable of interacting specifically with glycoprotein CD44 receptors overexpressed in tumor cells. Though the CHI/HA LbL films cannot be considered as a traditional biosensor due to their limited selectivity, it was possible to distinguish prostate tumor cells in the range from 50 to 600 cells/µL in in vitro experiments with impedance spectroscopy. This was achieved by treating the impedance data with information visualization methods, which confirmed the distinguishing ability of the films by observing the absence of false positives in a series of control experiments. The CD44–HA interactions may, therefore, be exploited in clinical analyses and point-of-care diagnostics for cancer, particularly if computational methods are used to process the data.

14 September 2018 in Journal of Polymers and the Environment
Verified
Journal Article
Closed access
PDF file
CMCynthia R. A. Mahl
Cynthia R. A. Mahl
TTThiago Bezerra Taketa
Thiago Bezerra Taketa
RBRogerio Bataglioli
Rogerio Bataglioli
EAEduardo José de Arruda
Eduardo José de Arruda
MBMarisa M. Beppu
Marisa M. Beppu

1 September 2020 in International Journal of Biological Macromolecules
Verified
Journal Article
Closed access
JNJ.B.M. Rocha Neto
J.B.M. Rocha Neto
RNR.J. Gomes Neto
R.J. Gomes Neto
RBRogerio Bataglioli
Rogerio Bataglioli
TTT.B. Taketa
T.B. Taketa
SPS.B. Pimentel
S.B. Pimentel
MBMarisa Masumi Beppu
Marisa Masumi Beppu