NIKOLAOS PAPAMICHALOPOULOS

Dr. NIKOLAOS PAPAMICHALOPOULOS


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2021 in Microorganisms
Verified
Journal Article
Open access
PDF file
NVNiki Vassilaki
Niki Vassilaki
Antonios N. GargalionisAntonios N. Gargalionis
Antonios N. Gargalionis
ABAnastasia Bletsa
Anastasia Bletsa
NPNIKOLAOS PAPAMICHALOPOULOS
NIKOLAOS PAPAMICHALOPOULOS
EKElisavet Kontou Elisavet Kontou
Elisavet Kontou Elisavet Kontou
SCStylianos Chatzipanagiotou
Stylianos Chatzipanagiotou
Anti-SARS-CoV-2 spike RBD (receptor-binding domain) IgG antibody levels were monitored in 1643 volunteer healthcare workers of Eginition, Evangelismos, and Konstantopoulio General Hospitals (Athens, Greece), who underwent vaccination with two doses of COVID-19 BNT162b2 mRNA vaccine (Pfizer) and had no history of SARS-CoV-2 infection. Venous blood was collected 20–30 days after the second vaccine dose and anti-RBD IgG levels were determined using CMIA SARS-CoV-2 IgG II Quant (Abbott) on ARCHITECT i System or ADVIA Centaur SARS-CoV-2 IgG (Siemens) on Centaur XP platform. From the total population of 1643 vaccinees (533 M/1110 F; median age = 49; interquartile range-IQR = 40–56), 1636 (99.6%) had anti-SARS-CoV-2 IgG titers above the positivity threshold of the assay used. One-Way ANOVA Kruskal-Wallis H test showed a statistically significant difference in the median of antibody titers between the different age groups (p < 0.0001). Consistently, Spearman’s correlation coefficient (r) for IgGs and age as continuous variables was −0.2380 (p = 1.98 × 10−17). Moreover, antibody titers were slightly higher by 1.2-mean fold (p = 3 × 10−6) in the total female population of the three hospitals (median = 1594; IQR = 875–2584) as compared to males (median = 1292; IQR = 671.9–2188). The present study supports that BNT162b2 vaccine is particularly effective in producing high anti-SARS-CoV-2 IgG levels in healthy individuals, and this humoral response is age- and gender-dependent.

11 November 2022 in Microorganisms
Verified
Journal Article
Open access
PDF file
Helena MaltezouHelena Maltezou
Helena Maltezou
EHElina Horefti
Elina Horefti
NPNIKOLAOS PAPAMICHALOPOULOS
NIKOLAOS PAPAMICHALOPOULOS
MTMaria Tseroni
Maria Tseroni
IAIOANNIDIS ANASTASIOS
IOANNIDIS ANASTASIOS
SCStylianos Chatzipanagiotou
Stylianos Chatzipanagiotou
(1) Background: Surfaces have been implicated in the transmission of infections. We aimed to assess how effective an usnic-acid-containing self-decontaminating coating was on the surfaces of the Athens underground metro. (2) Methods: Two samples were collected from each of 60 surfaces of a station and a wagon before the application of the coating and 9 and 20 days after, and they were tested for bacteria, fungi, and SARS-CoV-2 using conventional microbiological and molecular methods. Bacteria and fungi growth were expressed in colony forming units (CFUs)/102cm2. (3) Results: Before the application of the coating, 50% of the samples tested positive for the targeted microbes: 91.7% for bacteria, 18.3% for fungi, and 8.3% for SARS-CoV-2. After nine days, 3.3% of the samples tested positive for bacteria and 6.6% after 20 days. The average amount of bacteria before the coating was applied was 8.5 CFU/102cm2 compared to 0 and 0 CFU/102cm2 after application (100% and 95% reduction); all samples collected after the application were negative for SARS-CoV-2 and fungi (100% reduction). (4) Conclusion: An usnic-acid-containing self-decontaminating coating was highly effective in eliminating bacterial, fungal, and SARS-CoV-2 contamination of surfaces in the underground metro.

Helena MaltezouHelena Maltezou
Helena Maltezou
NPNIKOLAOS PAPAMICHALOPOULOS
NIKOLAOS PAPAMICHALOPOULOS
EHElina Horefti
Elina Horefti
MTMaria Tseroni
Maria Tseroni
AKAmalia Karapanou
Amalia Karapanou
NSNIKOLAOS SIPSAS
NIKOLAOS SIPSAS
Surfaces have been implicated in the transmission of pathogens in hospitals. This study aimed to assess the effectiveness of an usnic-acid-containing self-decontaminating coating in reducing microbial surface contamination in tertiary-care hospitals. Samples were collected from surfaces 9 days before coating application, and 3, 10, and 21 days after its application (phases 1, 2, 3, and 4, respectively). Samples were tested for bacteria, fungi, and SARS-CoV2. In phase 1, 53/69 (76.8%) samples tested positive for bacteria, 9/69 (13.0%) for fungi, and 10/139 (7.2%) for SARS-CoV-2. In phase 2, 4/69 (5.8%) samples tested positive for bacteria, while 69 and 139 samples were negative for fungi and SARS-CoV-2, respectively. In phase 3, 3/69 (4.3%) samples were positive for bacteria, 1/139 (0.7%) samples tested positive for SARS-CoV-2, while 69 samples were negative for fungi. In phase 4, 1/69 (1.4%) tested positive for bacteria, while no fungus or SARS-CoV-2 were detected. After the coating was applied, the bacterial load was reduced by 87% in phase 2 (RR = 0.132; 95% CI: 0.108–0.162); 99% in phase 3 (RR = 0.006; 95% CI: 0.003–0.015); and 100% in phase 4 (RR = 0.001; 95% CI: 0.000–0.009). These data indicate that the usnic-acid-containing coating was effective in eliminating bacterial, fungal, and SARS-CoV-2 contamination on surfaces in hospitals.Our findings support the benefit ofan usnic-acid-containing coating in reducing the microbial load on healthcare surfaces.