Munenobu Nogami

Prof. Munenobu Nogami

Kobe University Hospital, Kōbe, Hyōgo, Japan
+1
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 July 2009 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
DTDaisuke Takenaka
Daisuke Takenaka
YOYoshiharu Ohno
Yoshiharu Ohno
KMKeiko Matsumoto
Keiko Matsumoto
NANobukazu Aoyama
Nobukazu Aoyama
YOYumiko Onishi
Yumiko Onishi
KSKazuro Sugimura
Kazuro Sugimura
Purpose: To prospectively compare the capability for bone metastasis assessment of whole‐body diffusion‐weighted imaging (DWI), magnetic resonance imaging (MRI) without and with DWI, [18F] fluoro‐2‐D‐glucose positron emission tomography with computed tomography (FDG‐PET/CT) and bone scintigraphy in non‐small cell carcinoma (NSCLC) patients.Materials and Methods: In all, 115 consecutive NSCLC patients (66 men, 49 women; mean age 72 years) prospectively underwent whole‐body MRI, PET/CT, and bone scintigraphy before treatment. For each method, probability of metastasis was independently assessed by using a 5‐point visual scoring system on a per‐site basis. Receiver operating characteristic (ROC)‐based positive tests were used to determine the practical threshold value for each method on a per‐site basis. Sensitivities, specificities, and accuracies were then compared on a per‐site and per‐patient basis by means of McNemar's test.Results: When the practical threshold values were adapted, specificity and accuracy of whole‐body MRI with DWI were significantly higher than those of bone scintigraphy and PET/CT (P < 0.05). On a per‐patient basis, specificity and accuracy of whole‐body MRI with DWI were significantly higher than those of bone scintigraphy (P < 0.05).Conclusion: Whole‐body MRI with DWI can be used for bone metastasis assessment of NSCLC patients as accurate as bone scintigraphy and/or PET/CT. J. Magn. Reson. Imaging 2009;30:298–308.

16 April 2020 in European Radiology
Verified
Journal Article
Open access
PDF file
FZFeibi Zeng
Feibi Zeng
MNMunenobu Nogami
Munenobu Nogami
YUYoshiko R. Ueno
Yoshiko R. Ueno
TKTomonori Kanda
Tomonori Kanda
KSKeitaro Sofue
Keitaro Sofue
TMTakamichi Murakami
Takamichi Murakami
Objectives: This study aimed to evaluate the diagnostic performance of the lung zero-echo time (ZTE) sequence in FDG PET/MRI for detection and differentiation of lung lesions in oncologic patients in comparison with conventional two-point Dixon-based MR imaging. Methods: In this single-institution retrospective study approved by the institutional review board, 209 patients with malignancies (97 men and 112 women; age range, 17–89 years; mean age, 66.5 ± 12.9 years) underwent 18F-FDG PET/MRI between August 2017 and August 2018, with diagnostic Dixon and ZTE under respiratory gating acquired simultaneously with PET. Image analysis was performed for PET/Dixon and PET/ZTE fused images by two readers to assess the detectability and differentiation of lung lesions. The reference standard was pathological findings and/or the data from a chest CT. The detection and differentiation abilities were evaluated for all lesions and subgroups divided by lesion size and maximum standardized uptake value (SUVmax). Results: Based on the reference standard, 227 lung lesions were identified in 113 patients. The detectability of PET/ZTE was significantly better than that of PET/Dixon for overall lesions, lesions with a SUVmax less than 3.0 and lesions smaller than 4 mm (p < 0.01). The diagnostic performance of PET/ZTE was significantly better than that of PET/Dixon for overall lesions and lesions smaller than 4 mm (p < 0.01). Conclusions: ZTE can improve diagnostic performance in the detection and differentiation of both FDG-avid and non-FDG-avid lung lesions smaller than 4 mm in size, yielding a promising tool to enhance the utility of FDG PET/MRI in oncology patients with lung lesions. Key Points: • The detection rate of PET/ZTE for lesions with a SUVmax of less than 1.0 was significantly better than that of PET/Dixon. • The performance for differentiation of PET/ZTE for lesions that were even smaller than 4 mm in size were significantly better than that of PET/Dixon. • Inter-rater agreement of PET/ZTE for the differentiation of lesions less than 4 mm in size was substantial and better than that of PET/Dixon.

4 March 2024 in Informatics in Medicine Unlocked
Verified
Journal Article
Open access
MNMizuho Nishio
Mizuho Nishio
TMTakaaki Matsunaga
Takaaki Matsunaga
HMHidetoshi Matsuo
Hidetoshi Matsuo
MNMunenobu Nogami
Munenobu Nogami
YKYasuhisa Kurata
Yasuhisa Kurata
TMTakamichi Murakami
Takamichi Murakami

28 June 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YUYasuyo Urase
Yasuyo Urase
MNMizuho Nishio
Mizuho Nishio
YUYoshiko Ueno
Yoshiko Ueno
AKAtsushi Kono
Atsushi Kono
KSKeitaro Sofue
Keitaro Sofue
TMTakamichi Murakami
Takamichi Murakami
The usefulness of sparse-sampling CT with deep learning-based reconstruction for detection of metastasis of malignant ovarian tumors was evaluated. We obtained contrast-enhanced CT images (n = 141) of ovarian cancers from a public database, whose images were randomly divided into 71 training, 20 validation, and 50 test cases. Sparse-sampling CT images were calculated slice-by-slice by software simulation. Two deep-learning models for deep learning-based reconstruction were evaluated: Residual Encoder-Decoder Convolutional Neural Network (RED-CNN) and deeper U-net. For 50 test cases, we evaluated the peak signal-to-noise ratio (PSNR) and structural similarity (SSIM) as quantitative measures. Two radiologists independently performed a qualitative evaluation for the following points: entire CT image quality; visibility of the iliac artery; and visibility of peritoneal dissemination, liver metastasis, and lymph node metastasis. Wilcoxon signed-rank test and McNemar test were used to compare image quality and metastasis detectability between the two models, respectively. The mean PSNR and SSIM performed better with deeper U-net over RED-CNN. For all items of the visual evaluation, deeper U-net scored significantly better than RED-CNN. The metastasis detectability with deeper U-net was more than 95%. Sparse-sampling CT with deep learning-based reconstruction proved useful in detecting metastasis of malignant ovarian tumors and might contribute to reducing overall CT-radiation exposure.

25 November 2020 in Diabetes, Obesity and Metabolism
Verified
Journal Article
Closed access
PDF file
JIJun Ito
Jun Ito
MNMunenobu Nogami
Munenobu Nogami
YMYasuko Morita
Yasuko Morita
KSKazuhiko Sakaguchi
Kazuhiko Sakaguchi
HKHisako Komada
Hisako Komada
WOWataru Ogawa
Wataru Ogawa

25 June 2007 in Annals of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
MNMunenobu Nogami
Munenobu Nogami
YNYuji Nakamoto
Yuji Nakamoto
SSSetsu Sakamoto
Setsu Sakamoto
KFKazuto Fukushima
Kazuto Fukushima
TOTomohisa Okada
Tomohisa Okada
KSKazuro Sugimura
Kazuro Sugimura