Jackson William Kiser

Dr. Jackson William Kiser

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2024 in Cancers
Verified
Journal Article
Open access
PDF file
AHAustin Richard Hoggarth
Austin Richard Hoggarth
SMSankar Muthukumar
Sankar Muthukumar
STSteven Mulackal Thomas
Steven Mulackal Thomas
JCJames Crowley
James Crowley
JKJackson William Kiser
Jackson William Kiser
MWMark R. Witcher
Mark R. Witcher
Gliomas represent the most commonly occurring tumors in the central nervous system and account for approximately 80% of all malignant primary brain tumors. With a high malignancy and recurrence risk, the prognosis of high-grade gliomas is poor, with a mean survival time of 12–18 months. While contrast-enhanced MRI serves as the standard diagnostic imaging modality for gliomas, it faces limitations in the evaluation of recurrent gliomas, failing to distinguish between treatment-related changes and tumor progression, and offers no direct therapeutic options. Recent advances in imaging modalities have attempted to address some of these limitations, including positron emission tomography (PET), which has demonstrated success in delineating tumor margins and guiding the treatment of recurrent gliomas. Additionally, with the advent of theranostics in nuclear medicine, PET tracers, when combined with therapeutic agents, have also evolved beyond a purely diagnostic modality, serving both diagnostic and therapeutic roles. This review will discuss the growing involvement of theranostics in diagnosing and treating recurrent gliomas and address the associated impact on quality of life and functional recovery.

12 January 2021 in Health Physics
Verified
Journal Article
Open access
DODustin Osborne
Dustin Osborne
JKJackson William Kiser
Jackson William Kiser
JKJosh Knowland
Josh Knowland
DTDavid Townsend
David Townsend
DFDarrell R. Fisher
Darrell R. Fisher
Extravasation is a common problem in radiopharmaceutical administration and can result in significant radiation dose to underlying tissue and skin. The resulting radiation effects are rarely studied and should be more fully evaluated to guide patient care and meet regulatory obligations. The purpose of this work was to show that a dedicated radiopharmaceutical injection monitoring system can help clinicians characterize extravasations for calculating tissue and skin doses. We employed a commercially available radiopharmaceutical injection monitoring system to identify suspected extravasation of 18F-fluorodeoxyglucose and 99mTc-methylene diphosphonate in 26 patients and to characterize their rates of biological clearance. We calculated the self-dose to infiltrated tissue using Monte Carlo simulation and standard MIRD dosimetry methods, and we used VARSKIN software to calculate the shallow dose equivalent to the epithelial basal-cell layer of overlying skin. For 26 patients, injection-site count rate data were used to characterize extravasation clearance. For each, the absorbed dose was calculated using representative tissue geometries. Resulting tissue-absorbed doses ranged from 0.6 to 11.2 Gy, and the shallow dose equivalent to a 10 cm2 area of adjacent skin in these patients ranged from about 0.1 to 5.4 Sv. Extravasated injections of radiopharmaceuticals can result in unintentional doses that exceed well-established radiation protection and regulatory limits; they should be identified and characterized. An external injection monitoring system may help to promptly identify and characterize extravasations and improve dosimetry calculations. Patient-specific characterization can help clinicians determine extravasation severity and whether the patient should be followed for adverse tissue reactions that may present later in time.

1 January 2022 in Molecular Imaging
Verified
Journal Article
Open access
PDF file
BSBrittany M. Stopa
Brittany M. Stopa
JCJames Crowley
James Crowley
CJCsaba Juhasz
Csaba Juhasz
CRCara Marie Rogers
Cara Marie Rogers
MWMark R. Witcher
Mark R. Witcher
JKJackson William Kiser
Jackson William Kiser
Introduction. Positron emission tomography (PET) imaging with prostate-specific membrane antigen- (PSMA-) binding tracers has been found incidentally to demonstrate uptake in CNS tumors. Following the encouraging findings of several such case reports, there is a growing interest in the potential application of PSMA-targeted PET imaging for diagnostics, theranostics, and monitoring of CNS tumors. This is a systematic literature review on PSMA-binding tracers in CNS tumors. Methods. A PubMed search was conducted, including preclinical and clinical reports. One hundred and twelve records were identified, and after screening, 56 were included in the final report. Results. Tissue studies demonstrated PSMA expression in tumor vascular endothelial cells, without expression in normal brain tissue, though the extent and intensity of staining varied by anti-PSMA antibody and methodology. Most included studies reported on gliomas, which showed strong PSMA ligand uptake and more favorable tumor to background ratios than other PET tracers. There are also case reports demonstrating PSMA ligand uptake in prostate cancer brain metastases, nonprostate cancer brain metastases, and meningiomas. We also review the properties of the various PSMA-binding radiotracers available. Therapeutic and theranostic applications of PSMA-binding tracers have been studied, including labeled alpha- and beta-ray emitting isotopes, as well as PSMA targeting in directing MRI-guided focused ultrasound. Conclusions. There is a potential application for PSMA-targeted PET in neuro-oncology as a combination of diagnostic and therapeutic use, as a theranostic modality for managing CNS tumors. Further research is needed regarding the mechanism(s) of PSMA expression in CNS tumors and its differential performance by tumor type.

15 May 2018 in Frontiers in Medicine
Verified
Journal Article
Open access
PDF file
JKJackson William Kiser
Jackson William Kiser
JCJames R. Crowley
James R. Crowley
DWDavid A. Wyatt
David A. Wyatt
RLRonald K. Lattanze
Ronald K. Lattanze
Major management decisions in patients with solid tumors and lymphomas are often based on 18F-fluorodeoxyglucose (18F-FDG) PET/CT. The misadministration of 18F-FDG outside the systemic circulation can have an adverse impact on this test's sensitivity (1) and is not uncommon (2–7). This report describes how an 18F-FDG misadministration led to a repeat PET/CT study, resulting in the visualization of distant metastases that changed the original treatment plan. The findings suggest that routine injection monitoring is indicated whenever sensitivity is critical, and support claims that infiltrations can confound interpretation of semi-quantitative PET outcome measures in patients who are followed longitudinally (2).

Verified
Journal Article
Open access
PDF file
SMSankar Muthukumar
Sankar Muthukumar
JDJordan Darden
Jordan Darden
JCJames Crowley
James Crowley
MWMark Witcher
Mark Witcher
JKJackson William Kiser
Jackson William Kiser
Humans with high-grade gliomas have a poor prognosis, with a mean survival time of just 12–18 months for patients who undergo standard-of-care tumor resection and adjuvant therapy. Currently, surgery and chemoradiotherapy serve as standard treatments for this condition, yet these can be complicated by the tumor location, growth rate and recurrence. Currently, gadolinium-based, contrast-enhanced magnetic resonance imaging (CE-MRI) serves as the predominant imaging modality for recurrent high-grade gliomas, but it faces several drawbacks, including its inability to distinguish tumor recurrence from treatment-related changes and its failure to reveal the entirety of tumor burden (de novo or recurrent) due to limitations inherent to gadolinium contrast. As such, alternative imaging modalities that can address these limitations, including positron emission tomography (PET), are worth pursuing. To this end, the identification of PET-based markers for use in imaging of recurrent high-grade gliomas is paramount. This review will highlight several PET radiotracers that have been implemented in clinical practice and provide a comparison between them to assess the efficacy of these tracers.

1 July 2020 in JCO Oncology Practice
Verified
Journal Article
Open access
JKJackson William Kiser
Jackson William Kiser
TBThad Benefield
Thad Benefield
RLRonald K. Lattanze
Ronald K. Lattanze
KRKelley A. Ryan
Kelley A. Ryan
JCJames Crowley
James Crowley
PURPOSE:Accurate administration of radiotracer dose is essential to positron emission tomography (PET) image quality and quantification. Misadministration (infiltration) of the dose can affect PET/computed tomography results and lead to unnecessary or inappropriate treatments and procedures. Quality control efforts ensure accuracy of the administered dose; however, they fail to ensure complete delivery of the dose into the patient's circulation. We used new technology to assess and improve infiltration rates and evaluate sustainability.METHODS:Injection quality was measured, improved, and sustained during our participation in a multicenter quality improvement project using Define, Measure, Analyze, Improve, Control methodology. Five technologists monitored injection quality in the Measure and Improve phases. After seven new technologists joined the team in the Control phase, infiltration rates were recalculated, controlling for technologist- and patient-level correlations, and comparisons were made between these two groups of technologists.RESULTS:In the Measure phase, five technologists monitored 263 injections (13.3% infiltration rate). Nonantecubital fossa injections had a higher probability of infiltration than antecubital fossa injections. After implementing a quality improvement plan (QIP), the same technologists monitored 278 injections in the Improve phase (2.9% infiltration rate). The 78% decrease in infiltration rate was significant (P < .001) as was the decrease in nonantecubital fossa infiltrations (P = .0025). In the Control phase, 12 technologists monitored 1,240 injections (3.1% infiltration rate). The seven new technologists had significantly higher rates of infiltration (P = .017).CONCLUSION:A QIP can significantly improve and sustain injection quality; however, ongoing monitoring is needed as new technologists join the team.