Zachery Harris

Mr. Zachery Harris

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2022 in IEEE Transactions on Terahertz Science and Technology
Verified
Journal Article
Closed access
ZHZachery Harris
Zachery Harris
MAM. Hassan Arbab
M. Hassan Arbab
Recently, we introduced a Portable HAndheld Spectral Reflection (PHASR) Scanner to allow terahertz time-domain spectroscopic (THz-TDS) imaging in clinical and industrial settings using a fiber-coupled and alignment-free telecentric beam-steering design. The key limitations of the version 1.0 of the PHASR Scanner were its field-of-view (FOV) and speed of time-domain trace acquisition. In this article, we address these limitations by introducing a heliostat geometry for beam scanning to achieve an extended FOV, and by reconfiguring the asynchronous optical sampling system to perform Electronically Controlled OPtical Sampling (ECOPS) measurements. The former change improved the deflection range of the beam, while also drastically reducing the coupling of the two scanning axes, the combination of which resulted in a larger than four-fold increase in the FOV area. The latter change significantly improves the acquisition speed and frequency-domain performance simultaneously by improving measurement efficiency. To accomplish this, we characterized the nonlinear time-axis sampling behavior of the electromechanical system in the ECOPS mode. We proposed methods to model and correct the nonlinear time-axis distortions and tested the performance of the high-speed ECOPS trace acquisition. Therefore, here, we introduce the PHASR Scanner version 2.0, which is capable of imaging a 40 × 27 mm 2 FOV with 2000 traces/s over a 100 ps TDS range. This new scanner represents a significant leap toward translating the THz-TDS technology from the lab bench to the bedside for real-time clinical imaging applications.

17 January 2022 in Advanced Photonics Research
Verified
Journal Article
Open access
PDF file
OOOmar B. Osman
Omar B. Osman
ZHZachery Harris
Zachery Harris
JZJuin W. Zhou
Juin W. Zhou
Mahmoud EbrahimkhaniMahmoud Ebrahimkhani
Mahmoud Ebrahimkhani
ASAdam J Singer
Adam J Singer
MAM. Hassan Arbab
M. Hassan Arbab
The accuracy of clinical assessment techniques in diagnosing partial‐thickness burn injuries has remained as low as 50–76%. Depending on the burn depth and environmental factors in the wound, such as reactive oxygen species, inflammation, and autophagy, partial‐thickness burns can heal spontaneously or require surgical intervention. Herein, it is demonstrated that terahertz time‐domain spectral imaging (THz‐TDSI) is a promising tool for in vivo quantitative assessment and monitoring of partial‐thickness burn injuries in large animals. We used a novel handheld THz‐TDSI scanner to characterize burn injuries in a porcine scald model with histopathological controls. Statistical analysis (n = 40) indicates that the THz‐TDSI modality can accurately differentiate between partial‐thickness and full‐thickness burn injuries (1‐way ANOVA, p < 0.05). THz‐TDSI has the potential to improve burn care outcomes by helping surgeons in making objective decisions for early excision of the wound.

8 November 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
Mahmoud EbrahimkhaniMahmoud Ebrahimkhani
Mahmoud Ebrahimkhani
OOOmar B. Osman
Omar B. Osman
ZHZachery Harris
Zachery Harris
ACAndrew Chen
Andrew Chen
JZJuin-Wan Zhou
Juin-Wan Zhou
MAM. Hassan Arbab
M. Hassan Arbab
According to the World Health Organization (WHO), 11 million burn injuries occur annually worldwide, 180,000 of which are fatal, with the vast majority occurring in low- and middle-income countries.1,2 Burn injuries result in significant skin necrosis and deep tissue damage.3 Burns created with different sources, such as scald, electrical, or flame injuries, invoke disparate pathophysiological responses, which necessitates using different treatment approaches.4 However, severe burns, regardless of their cause, lead to a highly dysregulated inflammatory response.5 The inflammatory response initiates tissue repair and the overall wound healing process to restore the skin barrier and the pliability and functionality of the skin.6,7 On the other hand, when the inflammatory cascade is triggered, it can also destroy the host tissue and contribute to organ failure.8 Moreover, wound healing is usually accompanied by the formation of abnormal, disfiguring lesions termed hypertrophic or keloid scars, which can lead to significant functional and social impairments.9,10 Early treatment of deep burns in the form of excision and grafting is critical for improving the healing process and reducing the infection rate to avoid excessive scarring.7,11

17 December 2020 in IEEE Access
Verified
Journal Article
Open access
ZHZachery Harris
Zachery Harris
Mahmoud EbrahimkhaniMahmoud Ebrahimkhani
Mahmoud Ebrahimkhani
MAM. Hassan Arbab
M. Hassan Arbab
We report on the development and characterization of a handheld terahertz (THz) time-domain spectroscopic scanner for broadband imaging between approximately 0.25 and 1.25 THz. We designed and fabricated a 3D-printed fiber-coupled housing which provides an alignment-free strategy for the placement and operation of the THz optics. Image formation is achieved through telecentric beam steering over a planar surface through a custom f- $\theta $ scanning lens. This design achieves a consistent resolution over the full $12\times 19$ mm field of view. Broadband spectral imaging is demonstrated using a 1951 United States Air Force Resolution Test Target. The consistency of the resolution over the wide field is validated through Boehler Star resolution measurements. Finally, a practical scenario of subsurface imaging on a damaged section of an aircraft wing is demonstrated. The THz PHASR is a field-deployable imaging system with the versatility to be applied to a much broader range of targets and imaging scenarios than previously possible, from industrial non-destructive testing to clinical diagnostic imaging.

30 January 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
Mahmoud EbrahimkhaniMahmoud Ebrahimkhani
Mahmoud Ebrahimkhani
ZHZachery Harris
Zachery Harris
OOOmar B. Osman
Omar B. Osman
ASAdam J. Singer
Adam J. Singer
MAM. Hassan Arbab
M. Hassan Arbab
The initial assessment of the depth of a burn injury during triage forms the basis for determination of the course of the clinical treatment plan. However, severe skin burns are highly dynamic and hard to predict. This results in a low accuracy rate of about 60 - 75% in the diagnosis of partial-thickness burns in the acute post-burn period. Terahertz time-domain spectroscopy (THz-TDS) has demonstrated a significant potential for non-invasive and timely estimation of the burn severity. Here, we describe a methodology for the measurement and numerical modeling of the dielectric permittivity of the in vivo porcine skin burns. We use the double Debye dielectric relaxation theory to model the permittivity of the burned tissue. We further investigate the origins of dielectric contrast between the burns of various severity, as determined histologically based on the percentage of the burned dermis, using the empirical Debye parameters. We demonstrate that the five parameters of the double Debye model can form an artificial neural network classification algorithm capable of automatic diagnosis of the severity of the burn injuries, and predicting its ultimate wound healing outcome by forecasting its re-epithelialization status in 28 days. Our results demonstrate that the Debye dielectric parameters provide a physics-based approach for the extraction of the biomedical diagnostic markers from the broadband THz pulses. This method can significantly boost dimensionality reduction of THz training data in artificial intelligence models and streamline machine learning algorithms.

1 December 2020 in AIP Advances
Verified
Journal Article
Open access
PDF file
ZHZachery Harris
Zachery Harris
SKStefan Katletz
Stefan Katletz
Mahmoud EbrahimkhaniMahmoud Ebrahimkhani
Mahmoud Ebrahimkhani
AVArjun Virk
Arjun Virk
MAM. Hassan Arbab
M. Hassan Arbab
Telecentric beam scanning using f-θ lenses offers nearly uniform spot size, linear beam displacement, and normal incidence angle over a planar surface. These unique properties allow for the minimization of imaging distortion over a wide field-of-view. In this article, we present a numerical method for designing custom f-θ lenses in the THz regime. We fabricated three lenses made from different commonly used polymer materials in the THz optics. We demonstrated their optical performance metrics compared to a conventional plano-convex lens over the broadband 0.3 THz–1 THz range. We find that the f-θ lens designed using the optical properties of high-density polyethylene achieved superior performance by maintaining a constant phase over a wide field of view of about 34°. We demonstrate this isophase property by measuring a constant time of arrival of the THz time-domain pulses over a reference mirror with a standard deviation of ∼19 fs, in excellent agreement with simulation predictions. This work will pave the way for the design and implementation of highly precise and fast telecentric imaging systems in the THz frequencies.