Background: The purpose of this study is to estimate the success rate of subliminal transscleral cyclophotocoagulation for refractory glaucoma and to determine the correlation between the decrease in intraocular pressure and the variation in choroidal thickness. Methods: A pre–post study was conducted over a period of 3 years, including 81 eyes from 67 patients with different types of drug-refractory glaucoma who underwent subliminal transscleral cyclophotocoagulation. The variables included best-corrected visual acuity, intraocular pressure and choroidal thickness. Results: We observed the following success rates (defined as IOP < 21 mmHg): 80% at 1 month (65 patients), 74% at 3 months (60 patients), 64% at 6 months (52 patients) and 50.6% at 1 year (41 patients). A strong correlation was noted between the decrease in intraocular pressure and the increase in the average choroidal thickness at 1 year (318.42 µm) compared to the average preoperative thickness (291.78 µm). A correlation of increased choroidal thickness at 1-month with the success rate of the procedure was also observed. Conclusions: We observed a statistically significant correlation between the success rate, decrease in intraocular pressure and choroidal thickness. The correlation of increased choroidal thickness at 1-month with the success rate of the procedure could be used clinically as a predictive factor for the final outcome of patients. Further experimental research is warranted to determine whether the increase in choroidal thickness after subliminal transscleral cyclophotocoagulation is indeed evidence of increased uveoscleral drainage.
Background/Objectives: Optical coherence tomography angiography (OCTA) enables noninvasive quantitative assessment of the retinal microvasculature and is widely used in diabetic retinopathy (DR). However, OCTA-derived metrics are highly dependent on post-processing techniques, particularly vessel binarization. This study aimed to compare local and global binarization methods applied after Frangi filtering for vessel enhancement in parafoveal vessel density analysis. Methods: This cross-sectional study included 69 participants: 17 healthy controls and 52 diabetic patients, classified as the following: no DR (n = 14), non-proliferative DR (NPDR, n = 18), or proliferative DR (PDR, n = 20). All subjects underwent comprehensive ophthalmological examination and OCTA imaging of the superficial capillary plexus using a Topcon OCTA system. Images were processed using a custom MATLAB protocol. Following Frangi filtering, five binarization methods were applied: three local (Phansalkar, local Otsu, adaptive mean) and two global (global mean and global Otsu). Parafoveal vessel density was quantified within the four inner quadrants of the ETDRS grid. Results: Statistically significant differences in vessel density were consistently observed between PDR group and both the control and no DR groups across all local binarization methods. Among global methods, only global Otsu thresholding detected a significant difference between PDR and control. The most robust differences were predominantly identified in the nasal and inferior quadrants. Conclusions: Local adaptive binarization methods demonstrated superior sensitivity and structural preservation for parafoveal vessel density analysis in DR. Global methods showed limited discriminative capability. These findings support the preferential use of local adaptive techniques for reliable OCTA-based vascular assessment in diabetic retinopathy.
Diabetic retinopathy is the leading cause of visual loss and blindness in working-age adults and represents the most common microvascular complication of diabetes mellitus. The current research assesses the retinal arterioles status in healthy volunteers and diabetic patients, in order to detect early retinal changes by using adaptive optics ophthalmoscopy (AOO), a cutting edge, noninvasive imaging technique. Our patients were evaluated between 2021-2022 in the Retina Clinic Bucharest, Romania. All of them underwent a complete ophthalmologic examination. By using rtx1™ adaptive optics retinal camera (Imagine Eyes, Orsay, France) together with the manufacturer’s software (AO detect artery, Imagine Eyes, France), several vascular parameters of the retinal arteriole were calculated, including wall to lumen ratio (WLR), vessel diameter (VD), lumen diameter (LD), mean wall thickness (WT) and cross-sectional area of the vascular wall (WCSA). All five studied vascular parameters were found to have higher values in diabetic patients, when compared to healthy volunteers. The differences were statistically significant for WT, WLR and WCSA (p values under 0.05). Adaptive optics ophthalmoscopy represents a cutting-edge technique, opening a new era in the medical retina field. It provides useful data regarding the retinal vascular status, in a non-invasive manner, being a promising tool in the diagnosis, staging and follow-up of diabetic retinal disease.