To evaluate whether an impaired anterior visual pathway (retinal structures with microvasculature) is associated with underlying beta-amyloid (Aβ) pathologies in patients with Alzheimer’s disease dementia (ADD) and mild cognitive impairment (MCI), we compared retinal structural and vascular factors in each subgroup with positive or negative amyloid biomarkers. Twenty-seven patients with dementia, thirty-five with MCI, and nine with cognitively unimpaired (CU) controls were consecutively recruited. All participants were divided into positive Aβ (A+) or negative Aβ (A−) pathology based on amyloid positron emission tomography or cerebrospinal fluid Aβ. The retinal circumpapillary retinal nerve fiber layer thickness (cpRNFLT), macular ganglion cell/inner plexiform layer thickness (mGC/IPLT), and microcirculation of the macular superficial capillary plexus were measured using optical coherence tomography (OCT) and OCT angiography. One eye of each participant was included in the analysis. Retinal structural and vascular factors significantly decreased in the following order: dementia < MCI < CU controls. The A+ group had significantly lower microcirculation in the para- and peri-foveal temporal regions than did the A−. However, the structural and vascular parameters did not differ between the A+ and A− with dementia. The cpRNFLT was unexpectedly greater in the A+ than in the A− with MCI. mGC/IPLT was lower in the A+ CU than in the A− CU. Our findings suggest that retinal structural changes may occur in the preclinical and early stages of dementia but are not highly specific to AD pathophysiology. In contrast, decreased temporal macula microcirculation may be used as a biomarker for the underlying Aβ pathology.
Purpose: This study aimed to evaluate the 1-year surgical outcomes of XEN45 gel stent implantation with an open conjunctiva approach in patients with open-angle glaucoma (OAG).Methods: This retrospective cohort study included 19 eyes of 19 patients who underwent XEN45 gel stent implantation with an open conjunctival approach. Surgical success was defined by intraocular pressure (IOP) ≤18 mmHg and one of the following: IOP reduction ≥30% or reduction of two glaucoma medications with final IOP if baseline IOP ≤18 mmHg. The cumulative probability of success rate was analyzed using Kaplan-Meier survival analysis. Cox proportional hazard regression analysis was used to assess prognostic factors for surgical failure.Results: IOP reduced from 32.37 ± 12.08 mmHg preoperatively to 15.14 ± 2.25 mmHg at 1 year (p = 0.001). The number of glaucoma medication reduced from 3.89 ± 0.32 preoperatively to 0.86 ± 1.35 at 1 year (p = 0.001). The success rates were 78.9% at 6 months and 73.7% at 1 year. Eyes with bleb horizontal extent ≥2 clock hours at 1 month postoperatively had a significantly higher success rate (log-rank test, p < 0.001). Greater bleb horizontal extent at 2 weeks and 1 month postoperatively was associated with a lower surgical failure rate (2 weeks: hazard ratio, 0.119; p = 0.024; 1 month: hazard ratio, 0.046; p = 0.007). Bleb needling and additional glaucoma surgeries were necessary in 10 (52.6%) and five eyes (26.3%), respectively.Conclusions: XEN45 gel stent implantation with the open conjunctiva approach is effective in reducing IOP and glaucoma medication for over 1 year in patients with OAG.
Introduction: Little has been known about the intrableb structures associated with bleb function after trabeculectomy with amniotic membrane transplantation (AMT). The aim of this study is to analyze the characteristics of intrableb structures using anterior segment optical coherence tomography (AS-OCT) after trabeculectomy with AMT. Methods: A total of 68 eyes of 68 patients with primary open-angle glaucoma who underwent trabeculectomy with AMT were included. Surgical success was defined as intraocular pressure (IOP) ≤ 18 mmHg and IOP reduction of ≥ 20% without medication on AS-OCT examination. Intrableb parameters, including bleb height, bleb wall thickness, striping layer thickness, bleb wall reflectivity, fluid-filled space score, fluid-filled space height, and microcyst formation were evaluated using AS-OCT. Logistic regression analysis was performed to determine factors associated with IOP control. Results: Of the 68 eyes, 56 eyes were assigned to the success group and 12 eyes to the failure group. In the success group, bleb height (P = 0.009), bleb wall thickness (P = 0.001), striping layer thickness (P = 0.001), fluid-filled space score (P = 0.001), and frequency of microcyst formation (P = 0.001) were greater than those in the failure group. Bleb wall reflectivity was higher in the failure group than in the success group (P < 0.001). In the univariate logistic regression analysis, previous cataract surgery was significantly associated with surgical failure (odds ratio = 5.769, P = 0.032). Conclusion: A posteriorly extending fluid-filled space, tall bleb with low reflectivity, and thick striping layer were characteristics of successful filtering blebs after trabeculectomy with AMT.
Purpose. The aim is to evaluate the effect of amniotic membrane transplantation (AMT) on trabeculectomy with mitomycin C in patients with pseudoexfoliation glaucoma (PXG). Methods. This retrospective cohort study included 85 eyes of PXG who underwent trabeculectomy with or without AMT (52/33 eyes in the AMT/control group). Surgical success was defined by these criteria: (1) intraocular pressure (IOP) ≤18 mmHg and IOP reduction 20% and (2) IOP ≤15 mmHg and IOP reduction 25%. Criteria A and B defined complete success rates as patients who met these criteria without medication, respectively. Criteria C and D defined qualified success rates as patients who met these criteria with medication, respectively. Cumulative probabilities of success were compared using the Kaplan–Meier survival analysis. Cox proportional hazard models were used to evaluate the influence of AMT on surgical success accounting for confounding variables. Results. For the AMT group, compared with the control group, the complete success rates at 12 months for criterion A were 86.5% and 63.6%, respectively ( ) and for criterion B, 86.4% and 63.6% ( ). The qualified success rates at 12 months for criterion C were 92.1% and 75.1%, respectively ( ) and for criterion D, 92.1% and 72.1% ( ). On multivariable Cox regression analyses, AMT was associated with a lower failure rate on criteria A, B, and D (all ). Incidence of avascular bleb was higher in the control group than in the AMT group (7 vs 0 eyes; ). Conclusions. In patients with PXG, trabeculectomy with AMT was associated with higher success rates and a lower incidence of avascular bleb compared with conventional trabeculectomy. Research Registration. This retrospective cohort study was registered at the Clinical Trial Registry of Korea (https://cris.nih.go.kr/cris/index/index.do, KCT0007228).
Introduction: The purpose of this study was to compare the characteristics of filtering bleb with anterior segment optical coherence tomography (AS-OCT) according to amniotic membrane transplantation (AMT). Methods: One hundred and sixteen eyes of 103 glaucoma patients who underwent trabeculectomy with (AMT group; 85 eyes) or without AMT (control group; 31 eyes) were included. Intrableb parameters were evaluated with AS-OCT. Surgical success was defined as an intraocular pressure (IOP) ≤18 mm Hg and IOP reduction ≥20% without medication at the time of AS-OCT examination. Logistic regression analyses were performed to determine factors associated with IOP control. Results: In the eyes with successful IOP control, the fluid-filled space area, score, and height were greater for the AMT group than the control group (all ps < 0.001), while stripping layer thickness was greater and bleb wall reflectivity was lower for the control group than the AMT group (all ps < 0.001). Surgical success in the AMT group was associated with greater fluid-filled space score, lower bleb wall reflectivity, and microcyst formation (odds ratio [OR] = 8.016, 0.913, and 16.202, respectively, all ps ≤ 0.041). Lower bleb wall reflectivity alone was associated with surgical success in the control group (OR = 0.815, p = 0.019). Conclusion: The extent of the fluid-filled space was associated with successful IOP control after trabeculectomy with AMT. Hyporeflective bleb wall was associated with successful IOP control in AMT and control groups.
Background: This study assessed the efficacy of intense pulsed light (IPL) therapy for treating meibomian gland dysfunction (MGD), a key contributor to evaporative dry eye disease (DED), by comparing outcomes in patients with idiopathic MGD versus those with MGD induced by glaucoma medications. Methods: In a retrospective analysis of 45 patients, divided into groups based on glaucoma medication use (20 patients) and non-use (25 patients), all underwent four IPL sessions combined with meibomian gland expression (MGX) at 3-week intervals. Key metrics evaluated included Ocular Surface Disease Index (OSDI) scores, tear breakup time (TBUT), Schirmer I test scores, and meibography scores, pre- and post-treatment. Results: Significant improvements were observed in both groups across all parameters post-treatment, indicating enhanced tear film stability and meibomian gland function. The non-glaucoma group showed slightly greater improvements, suggesting the potential impact of glaucoma medications on MGD management. Conclusions: These findings underscore IPL therapy’s effectiveness in improving DED symptoms and meibomian gland function, highlighting its utility as a treatment option for patients with MGD, including those on glaucoma medications.