Weidong Yao

Dr. Weidong Yao

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2017 in British Journal of Anaesthesia
Verified
Journal Article
Open access
PDF file
WYWeidong Yao
Weidong Yao
BWBin Wang
Bin Wang
Background. Increased tongue thickness is likely to be associated with difficult airways. However, no methods to evaluate tongue thickness were available. Currently, tongue thickness can be measured by ultrasonography. The present study investigated the predictive value of tongue thickness to predict difficult tracheal intubation. Methods. Adult patients undergoing tracheal intubation and general anaesthesia were enrolled in the study. Tongue thickness was assessed using submental ultrasonography in the median sagittal plane before anaesthesia. Airway assessments were conducted. Ratios of tongue thickness to thyromental distance were calculated to investigate the potential predictive value of their combination. The primary outcome was difficult tracheal intubation. A multivariable logistic regression and receiver operating characteristic curve analysis were used. Results. In total, 2254 patients were analysed. One hundred and forty-two (6.3%) patients experienced difficult laryngoscopy, and 51 (2.3%) patients experienced difficult tracheal intubation. Increased tongue thickness (>6.1 cm) was an independent predictor for difficult tracheal intubation [sensitivity 0.75, 95% confidence interval (CI) 0.60–0.86; specificity 0.72, 95% CI 0.70–0.74]. An area under the curve of 0.78 (95% CI 0.77–0.80) for predicting difficult tracheal intubation was calculated. Increased ratios of tongue thickness to thyromental distance (>0.87) presented a considerable area under the curve (0.86, 95% CI 0.84–0.87), sensitivity (0.84, 95% CI 0.71–0.93), and specificity (0.79, 95% CI 0.77–0.81). Conclusions. Tongue thickness measured by ultrasonography and its ratio to thyromental distance present significant capacities to predict difficult tracheal intubation. Clinical trial registration. ChiCTR-RCS-14004539.

13 January 2022 in BMC Anesthesiology
Verified
Journal Article
Open access
PDF file
BWBin Wang
Bin Wang
WYWeidong Yao
Weidong Yao
QXQi Xue
Qi Xue
MWMingfang Wang
Mingfang Wang
JXJianling Xu
Jianling Xu
YZYe Zhang
Ye Zhang
Background: Accurate prediction of the difficult airway (DA) could help to prevent catastrophic consequences in emergency resuscitation, intensive care, and general anesthesia. Until now, there is no nomogram prediction model for DA based on ultrasound assessment. In this study, we aimed to develop a predictive model for difficult tracheal intubation (DTI) and difficult laryngoscopy (DL) using nomogram based on ultrasound measurement. We hypothesized that nomogram could utilize multivariate data to predict DTI and DL. Methods: A prospective observational DA study was designed. This study included 2254 patients underwent tracheal intubation. Common and airway ultrasound indicators were used for the prediction, including thyromental distance (TMD), modified Mallampati test (MMT) score, upper lip bite test (ULBT) score temporomandibular joint (TMJ) mobility and tongue thickness (TT). Univariate and the Akaike information criterion (AIC) stepwise logistic regression were used to identify independent predictors of DTI and DL. Nomograms were constructed to predict DL and DTL based on the AIC stepwise analysis results. Receiver operating characteristic (ROC) curves were used to evaluate the accuracy of the nomograms. Results: Among the 2254 patients enrolled in this study, 142 (6.30%) patients had DL and 51 (2.26%) patients had DTI. After AIC stepwise analysis, ULBT, MMT, sex, TMJ, age, BMI, TMD, IID, and TT were integrated for DL nomogram; ULBT, TMJ, age, IID, TT were integrated for DTI nomogram. The areas under the ROC curves were 0.933 [95% confidence interval (CI), 0.912–0.954] and 0.974 (95% CI, 0.954–0.995) for DL and DTI, respectively. Conclusion: Nomograms based on airway ultrasonography could be a reliable tool in predicting DA. Trial registration: Chinese Clinical Trial Registry (No. ChiCTR-RCS-14004539), registered on 13th April 2014.

27 May 2020 in Journal of International Medical Research
Verified
Journal Article
Open access
PDF file
TYTao Yu
Tao Yu
RWRong-Rong Wu
Rong-Rong Wu
FLFederico Longhini
Federico Longhini
BWBin Wang
Bin Wang
MWMing-Fang Wang
Ming-Fang Wang
XJXiao-Ju Jin
Xiao-Ju Jin
Objective: We investigated the “BURP” maneuver’s effect on the association between difficult laryngoscopy and difficult intubation, and predictors of a difficult airway. Methods: Adult patients who underwent general anesthesia and tracheal intubation from September 2016 to May 2018 were included. The “BURP” maneuver was performed when glottic exposure was classified as Cormack–Lehane grade 3 or 4, suggesting difficult laryngoscopy. The thyromental distance, modified Mallampati score, and interincisor distance were assessed before anesthesia. Results: Among this study’s 2028 patients, the “BURP” maneuver decreased difficult laryngoscopies from 428 (21.1%) to 124 (6.1%) cases and increased the difficult intubation to difficult laryngoscopy ratio from 53/428 (12.4%) to 52/124 (41.9%). For laryngoscopies classified as difficult without the “BURP” maneuver, the area under the curve (AUC) of the thyromental distance, modified Mallampati score, and interincisor distance was 0.60, 0.57, and 0.66, respectively. In difficult laryngoscopies using the “BURP” maneuver, the AUC of the thyromental distance, modified Mallampati score, and interincisor distance was 0.71, 0.67, and 0.76, respectively. Conclusions: The “BURP” maneuver improves the laryngoscopic view and assists in difficult laryngoscopies. Compared with difficult laryngoscopies without the “BURP” maneuver, those with the “BURP” maneuver are more closely associated with difficult intubations and are more predictable. Trial registration: www.chictr.org.cn identifier: ChiCTR-ROC- 16009050.

5 March 2015 in Irish Journal of Medical Science (1971 -)
Verified
Journal Article
Closed access
PDF file
TYT. Yu
T. Yu
BWB. Wang
B. Wang
XJX. J. Jin
X. J. Jin
RWR. R. Wu
R. R. Wu
HWH. Wu
H. Wu
YLY. H. Li
Y. H. Li

1 April 2019 in Minerva Anestesiologica
Verified
Journal Article
Closed access
BWBin Wang
Bin Wang
CZChangjian Zheng
Changjian Zheng
WYWeidong Yao
Weidong Yao
LGLing Guo
Ling Guo
HPHui Peng
Hui Peng
XJXiaoju Jin
Xiaoju Jin
Compared with men, women often have a shorter interincisor distance and a shorter thyromental distance but are less likely to have difficult airway. The hypothesis is that the prediction criteria of difficult airway differ between men and women. The aim of this study was to investigate differences in the prediction criteria of anatomic predictors for difficult airways in men and women. We enrolled adult patients who underwent general anesthesia and tracheal intubation. The interincisor distance, thyromental distance, modified Mallampati test results, upper lip bite test results, and tongue thickness of each patient were evaluated prior to the initiation of anesthesia. The primary outcome was difficult tracheal intubation. Receiver operating characteristic (ROC) curve analysis and Youden's index were used to determine the criteria for predictors in men and women. In total, 1059 men and 1195 women were examined. Compared with women, men had a higher incidence of difficult tracheal intubation (P3, >2, and >62 mm, respectively, for men, and ≤33 mm, ≤65 mm, >2, >1, and >60 mm, respectively, for women. The optimal cut-off values of predictors of difficult airway differ between males and females.

15 July 2022 in Shock
Verified
Journal Article
Open access
HWHongzhi Wang
Hongzhi Wang
WCWei Chen
Wei Chen
HCHao Cheng
Hao Cheng
CLCan Liu
Can Liu
WYWeidong Yao
Weidong Yao
YCYongquan Chen
Yongquan Chen
Objective: The present study aimed to investigate whether corrected flow time (FTc) in common carotid artery could predict volume responsiveness under mechanical ventilation and to further explore whether the sensitivity and specificity would be influenced by positive end-expiratory pressure (PEEP). Methods: The first stage of this study included 80 patients from the general surgery department undergoing laparotomy. After induction of general anesthesia, FTc in the common carotid artery was measured when hemodynamic indicators, such as blood pressure, heart rate, and cardiac output (CO), were stabilized. Then, 7 mg/kg (ideal body weight) of hydroxyethyl starch 130/0.4 sodium chloride was rapidly infused from the peripheral venous system. The infusion was completed within 15 minutes, and hemodynamic indicators were measured again immediately to evaluate volume responsiveness. The patients with change rate of CO (ΔCO ≥15%) were categorized into the responsive (R) group, whereas those with ΔCO <15% were categorized into the nonresponsive group (NR) group. In the second stage, 29 patients undergoing laparotomy were included. After induction of general anesthesia, PEEP of 0, 5, and 10 cmH2O was applied sequentially. Corrected flow time and hemodynamic indicators were recorded. Then, 7 mg/g of hydroxyethyl starch 130/0.4 sodium chloride was rapidly infused for 15 minutes, after which PEEP of 0, 5, and 10 cmH2O was applied sequentially, and the indicators were measured again. The patients with FTc equal to or less than the threshold in the first stage were categorized into the R group, otherwise into the NR group. Results: In the first stage of the study, CO and FTc differed significantly between the 2 groups, before and after volume load (P < 0.05). Mean arterial pressure in the R group was significantly different, whereas heart rate did not differ before and after fluid infusion. Also, heart rate and mean arterial pressure were not significantly different before and after fluid infusion in the NR group. The area under the receiver operating characteristic curve was 0.786 ± 0.056 (95% confidence interval, 0.676–0.896; P = 0.00) for FTc before infusing volume load for predicting volume responsiveness. In the second stage of the study, PEEP did not have significant effects on FTc (F 2, 56 = 1.930, P = 0.155), whereas volume load had statistically significant effects on FTc (F 1, 28) = 9.381, P < 0.05). Moreover, FTc differed significantly different before and after fluid infusion (P < 0.05). The area under the receiver operating characteristic curve for FTc in predicting volume responsiveness was 0.921, 0.805, and 0.719 when PEEP was 0, 5, and 10 cmH2O (P < 0.05), respectively, and the cutoff value of FTc for diagnosing volume responsiveness was 323.42 milliseconds, 326.69 milliseconds, and 312.03 milliseconds, respectively. Conclusion: Corrected flow time in the common carotid artery can predict volume responsiveness under mechanical ventilation, and the predictive performance is not influenced by PEEP. Clinical Trial Registration Clinical register number: ChicTR2000029519