Introduction: The primary objective of this study was to determine the efficiency of hydrogen peroxide (H2O2) techniques in disinfection of ICU rooms contaminated with multidrug-resistant organisms (MDRO) after patient discharge. Secondary objectives included comparison of the efficiency of a vaporizator (HPV, Bioquell®) and an aerosolizer using H2O2, and peracetic acid (aHPP, Anios®) in MDRO environmental disinfection, and assessment of toxicity of these techniques. Methods: This prospective cross-over study was conducted in five medical and surgical ICUs located in one University hospital, during a 12-week period. Routine terminal cleaning was followed by H2O2 disinfection. A total of 24 environmental bacteriological samplings were collected per room, from eight frequently touched surfaces, at three time-points: after patient discharge (T0), after terminal cleaning (T1) and after H2O2 disinfection (T2). Results: In total 182 rooms were studied, including 89 (49%) disinfected with aHPP and 93 (51%) with HPV. At T0, 15/182 (8%) rooms were contaminated with at least 1 MDRO (extended spectrum β–lactamase-producing Gram-negative bacilli 50%, imipenem resistant Acinetobacter baumannii 29%, methicillin-resistant Staphylococcus aureus 17%, and Pseudomonas aeruginosa resistant to ceftazidime or imipenem 4%). Routine terminal cleaning reduced environmental bacterial load (P <0.001) without efficiency on MDRO (15/182 (8%) rooms at T0 versus 11/182 (6%) at T1; P = 0.371). H2O2 technologies were efficient for environmental MDRO decontamination (6% of rooms contaminated with MDRO at T1 versus 0.5% at T2, P = 0.004). Patient characteristics were similar in aHPP and HPV groups. No significant difference was found between aHPP and HPV regarding the rate of rooms contaminated with MDRO at T2 (P = 0.313). 42% of room occupants were MDRO carriers. The highest rate of rooms contaminated with MDRO was found in rooms where patients stayed for a longer period of time, and where a patient with MDRO was hospitalized. The residual concentration of H2O2 appears to be higher using aHPP, compared with HPV. Conclusions: H2O2 treatment is efficient in reducing MDRO contaminated rooms in the ICU. No significant difference was found between aHPP and HPV regarding their disinfection efficiency.
A new molecular assay detecting toxigenic Clostridium difficile , the BD Max Cdiff (Becton, Dickinson), was evaluated with 360 diarrheal feces samples. It exhibited high sensitivity (97.7%) and specificity (99.7%). The positive (97.7%) and negative (99.7%) predictive values of this test allow an accurate answer within 2 h.
The aim of this study was to investigate the concordance between ventilator-associated events (VAE) and ventilator-associated lower respiratory tract infections (VA-LRTI), and their impact on outcome. This retrospective study was performed in five 10-bed ICUs of a teaching hospital, during a 2-year period. Ventilator-associated lower respiratory tract infections (VA-LRTI), including ventilator-associated tracheobronchitis (VAT) and ventilator-associated pneumonia (VAP) were prospectively diagnosed. The agreement between VAE, VAT and VAP was assessed by k statistics. A total of 1059 patients (15,029 ventilator-days) were included. 268 VAP (17.8 per 1000 ventilator-days), 127 VAT (8.5 per 1000 ventilator-days) and 262 VAE (17.4 per 1000 ventilator-days) were diagnosed. There was no agreement between VAT and VAE, and the agreement was poor between VAP and VAE (k = 0.12, 95% CI 0.03–0.20). VAE and VA-LRTI were associated with significantly longer duration of mechanical ventilation, ICU and hospital length of stay. VAP, VAT and VAE were not significantly associated with mortality in multivariate analysis. The agreement was poor between VAE and VAP. No agreement was found between VAE and VAT. VAE episodes were significantly associated with longer duration of mechanical ventilation and length of stay, but not with ICU mortality.
Moraxella nonliquefaciens is a Gram-negative coccobacillus considered as a commensal organism from the upper respiratory tract, with low pathogenic potential. The phenotypical conventional identification is difficult and the matrix-assisted laser desorption/ionization time-of-flight technology has increased the resolution of identification of this bacterium. We report a fatal case of endocarditis due to M. nonliquefaciens whose identification was confirmed by 16S rRNA, and we review the literature on this pathogen in endocarditis.
1 August 2011 in Infectious Disorders - Drug Targets
Real-time PCR methods are able to rapidly detect a wide panel of microorganisms. These methods are of interest in critically ill patients to determine the presence of bacteria in the blood and other biological samples, especially in those patients with prior antimicrobial treatment. In intensive care unit (ICU), the LightCycler SeptiFast (LC-SF) Test provides 1.5 to 2 fold higher positivity rate compared with conventional blood cultures. Although identification of the bacterium by LC-SF is rapid and sensitive, susceptibility test could not be performed using this technique, except the methicillin- resistance for Staphylococci. The conventional cultures remain necessary for samples in ICU because of the high incidence of multidrug-resistant bacteria and the need for antimicrobial susceptibility of the bacterium to treat the patient correctly. A negative result for a Gram positive or negative bacterium allows deescalating the initial antimicrobial treatment, and decreasing the pressure of selection. Moreover, it is necessary to understand and interpret a DNA signal knowing that a dead bacterial material may be detected in a patient without any infection. What is the clinical relevance of bacterial DNA present in the blood and does the DNAemia found reflect true infection? Cost-effectiveness of the real-time PCR should be determined. Meanwhile, this test should be restricted to severe clinical situations, especially ICU patients with severe sepsis. In the future, real-time PCR tests should include more pathogens and antimicrobial resistant targets.