Objectives: Evaluation of the clinical performance of ultra-low-dose computed tomography (CT) images of the shoulder joint on image-based diagnosis and three-dimensional (3D) printing surgical planning. Materials and methods: A total of 93 patients with displaced shoulder fractures were randomly divided into standard-dose, low-dose, and ultra-low-dose groups. Three-dimensional printing models of all patients’ shoulder joints were fabricated. The subjective image quality and 3D-printing model were evaluated by two senior orthopedic surgeons who were blinded to any scanning setting. A 3-point scale system was used to quantitatively assess the image quality and 3D printing model, where more than 2 points meant adequate level for clinical application. Results: Compared with the standard dose protocol, ultra-low-dose technique reduced the radiation dose by 99.29% without loss of key image quality of fracture pattern. Regarding the subjective image quality, the assessment scores for groups of standard, low, and ultra-low doses were 3.00, 2.76, 2.00 points on scapula and humerus, and 3.00, 2.73, 2.44 points on clavicle. Scores of the three groups for the assessment of 3D printing models were 3.00, 2.80, 1.34 on scapula and humerus, and 3.00, 2.90, 2.06 on clavicle. In the ultra-low-dose group, 24 out of 33 (72.7%) 3D printing models of scapula and humerus received lower than 2 points of the evaluation score, while nearly 94% of the clavicle models reached the adequate level. Conclusion: An ultra-low-dose protocol is adequate for the diagnosis of either displaced or non-displaced fractures of the shoulder joint even though minor flaws of images are present. Three-dimensional printing models of shoulder joints created from ultra-low-dose CT scans can be used for surgical planning at specific bone like the clavicle but perform insufficiently in the overall surgical planning for shoulder injuries due to the significant geometric flaws.
Purpose: This study aims to examine the use of 3D printing technology to treat clavicular fractures by skilled and inexperienced surgeons. Methods: A total of 80 patients with clavicle fractures (from February 2017 to May 2021) were enrolled in this study. Patients were divided randomly into four groups: group A: Patients underwent low-dose CT scans, and 3D models were printed before inexperienced surgeons performed surgeries; group B: Standard-dose CT were taken, and 3D models were printed before experienced surgeons performed surgeries; group C and D: Standard-dose CT scans were taken in both groups, and the operations were performed differently by inexperienced (group C) and experienced (group D) surgeons. This study documented the operation time, blood loss, incision length, and the number of intraoperative fluoroscopies. Results: No statistically significant differences were found in age, gender, fracture site, and fracture type (P value: 0.23–0.88). Group A showed shorter incision length and fewer intraoperative fluoroscopy times than groups C and D (P < 0.05). There were no significant differences in blood loss volume, incision length, and intraoperative fluoroscopy times between group A and group B (P value range: 0.11–0.28). The operation time of group A was no longer than those of groups C and D (P value range: 0.11 and 0.24). Conclusion: The surgical effectiveness of inexperienced surgeons who applied 3D printing technology before clavicular fracture operation was better than those of inexperienced and experienced surgeons who did not use preoperative 3D printing technology.
Objective: To explore the feasibility of the three-dimensional printing (3DP) knee model using the ultra-low-dose computed tomography (CT) scan for preoperative planning and simulated surgery. Methods: Thirty-six patients were divided into the standard-dose protocol group (A) and ultra-low-dose protocol group (B). The anteroposterior diameter, left and right diameter of femur, anteroposterior diameter of tibial plateau (APTP), left and right diameter, distance from the intercondylar ridge to tibial tuberosity, lower femur angle, and upper tibial angle were measured on CT images. On the 3D printed knee joint model, Vernier calipers were used to measure: anteroposterior diameter, left and right diameter of the internal and external condyles of femur; left and right diameters, anteroposterior diameters of tibial plateau; upper and lower meridian, left and right diameters of patella. Results: With group A as reference, the effective radiation dose in group B was significantly reduced to 97.0% (36.4 ± 3.7 uSv and 1.1 ± 0.2 uSv, respectively). There was no difference in objective parameters for 3DP model (p = 0.31–0.84). None of the quantitative parameters of image quality showed significant difference (p = 0.11–0.96). Despite lower score of image quality and 3DP model in group B (3.0 ± 0.0 vs. 2.1 ± 0.2, 2.9 ± 0.3 vs. 2.2 ± 0.4; p < 0.05), the diagnostic performance was consistent in the two groups (all scores ≥ 2). Image quality and 3DP printed models were highly consistent (k = 0.97). Conclusions: Ultra-low-dose protocol reduces the radiation dose while maintaining the image quality of knee. It meets the requirement for 3DP model, internal fixation model selection, and simulated surgery.
17 July 2024 in Journal of Imaging Informatics in Medicine