In the signal analysis context, the entropy concept can characterize signal properties for detecting anomalies or non-representative behaviors in fiscal systems. In motor fault detection theory, entropy can measure disorder or uncertainty, aiding in detecting and classifying faults or abnormal operation conditions. This is especially relevant in industrial processes, where early motor fault detection can prevent progressive damage, operational interruptions, or potentially dangerous situations. The study of motor fault detection based on entropy theory holds significant academic relevance too, effectively bridging theoretical frameworks with industrial exigencies. As industrial sectors progress, applying entropy-based methodologies becomes indispensable for ensuring machinery integrity based on control and monitoring systems. This academic endeavor enhances the understanding of signal processing methodologies and accelerates progress in artificial intelligence and other modern knowledge areas. A wide variety of entropy-based methods have been employed for motor fault detection. This process involves assessing the complexity of measured signals from electrical motors, such as vibrations or stator currents, to form feature vectors. These vectors are then fed into artificial-intelligence-based classifiers to distinguish between healthy and faulty motor signals. This paper discusses some recent references to entropy methods and a summary of the most relevant results reported for fault detection over the last 10 years.
Induction motors are widely used worldwide for domestic and industrial applications. Fault detection and classification techniques based on signal analysis have increased in popularity due to the growing use of induction motors in new technologies such as electric vehicles, automatic control, maintenance systems, and the inclusion of renewable energy sources in electrical systems, among others. Hence, monitoring, fault detection, and classification are topics of interest for researchers, given that the presence of a fault can lead to catastrophic consequences concerning technical and financial aspects. To detect a fault in an induction motor, several techniques based on different physical variables, such as vibrations, current signals, stray flux, and thermographic images, have been studied. This paper reviews recent investigations into physical variables, instruments, and techniques used in the analysis of faults in induction motors, aiming to provide an overview on the pros and cons of using a certain type of physical variable for fault detection. A discussion about the detection accuracy and complexity of the signals analysis is presented, comparing the results reported in recent years. This work finds that current and vibration are the most popular signals employed to detect faults in induction motors. However, stray flux signal analysis is presented as a promising alternative to detect faults under certain operating conditions where other methods, such as current analysis, may fail.
Broken rotor bars in induction motors make up one of the typical fault types that are challenging to detect. This type of damage can provoke adverse effects on the motors, such as mechanical and electrical stresses, together with an increase in electricity consumption, causing higher operative costs and losses related to the maintenance times or even the motor replacement if the damage has led to a complete failure. To prevent such situations, diverse signal processing algorithms have been applied to incipient fault detection, using different variables to analyze, such as vibrations, current, or flux. To counteract the broken rotor bar damage, this paper focuses on a motor current signal analysis for early broken bar detection and classification by using the digital Taylor–Fourier transform (DTFT), whose implementation allows fine filtering and amplitude estimation with the final purpose of achieving an incipient fault detection. The detection is based on an analysis of variance followed by a Tukey test of the estimated amplitude. The proposed methodology is implemented in Matlab using the O-splines of the DTFT to reduce the computational load compared with other methods. The analysis is focused on groups of 50-test of current signals corresponding to different damage levels for a motor operating at 50% and 75% of its full load.
The actual tendency in electric systems for industrial and academic applications is to lead them to the smart systems philosophy. Nowadays, electronic instrumentation is an interesting area for researchers for electric motors’ control, monitoring, and maintenance purposes. Motor current signal analysis is one of the most used methods for fault detection in electric machines due to its noninvasive nature and the vast amount of information it contains; several techniques have been developed for bearing fault detection based on current signals, commonly through a spectrum analysis. Because of this, this paper proposes a methodology based on the rate of change of frequency estimation and a machine learning classifier (k-nearest neighbors). In this work, bearing ball damage and outer race damage scenarios were analyzed using the proposed method via the Digital Taylor-Fourier Transform, resulting in accuracy percentages of 97% and 94% for each case, respectively. That methodology does not require characterization supervised by a qualified person.
This paper proposes a feature-based methodology for early bearing fault detection and classification in induction motors through current signals using the digital Taylor–Fourier transform (DTFT) and statistical methods. The DTFT allows the application of narrow bandwidth digital filters located in the spurious current signal components, wherewith it is possible to gain information to detect bearing issues and classify them using statistical methods. The methodology was implemented in MATLAB using the digital Taylor–Fourier transform for three fault types (bearing ball damage, outer-race damage, and corrosion damage) at different powering conditions: power grid source at 60 Hz and adjustable speed drive applied (60 Hz, 50 Hz, 40 Hz, 30 Hz, 20 Hz, and 10 Hz) in loading and unloading conditions. Results demonstrate a classification accuracy between 93–99% for bearing ball damage, 91–99% for outer-race damage, and 94–99% for corrosion damage.